1 | Binding for TI bq25890 Li-Ion Charger |
2 | ||
3 | Required properties: | |
4 | - compatible: Should contain one of the following: | |
5 | * "ti,bq25890" | |
6 | - reg: integer, i2c address of the device. | |
7 | - ti,battery-regulation-voltage: integer, maximum charging voltage (in uV); | |
8 | - ti,charge-current: integer, maximum charging current (in uA); | |
9 | - ti,termination-current: integer, charge will be terminated when current in | |
10 | constant-voltage phase drops below this value (in uA); | |
11 | - ti,precharge-current: integer, maximum charge current during precharge | |
12 | phase (in uA); | |
13 | - ti,minimum-sys-voltage: integer, when battery is charging and it is below | |
14 | minimum system voltage, the system will be regulated above | |
15 | minimum-sys-voltage setting (in uV); | |
16 | - ti,boost-voltage: integer, VBUS voltage level in boost mode (in uV); | |
17 | - ti,boost-max-current: integer, maximum allowed current draw in boost mode | |
18 | (in uA). | |
19 | ||
20 | Optional properties: | |
21 | - ti,boost-low-freq: boolean, if present boost mode frequency will be 500kHz, | |
22 | otherwise 1.5MHz; | |
23 | - ti,use-ilim-pin: boolean, if present the ILIM resistor will be used and the | |
24 | input current will be the lower between the resistor setting and the IINLIM | |
25 | register setting; | |
26 | - ti,thermal-regulation-threshold: integer, temperature above which the charge | |
27 | current is lowered, to avoid overheating (in degrees Celsius). If omitted, | |
28 | the default setting will be used (120 degrees); | |
29 | ||
30 | Example: | |
31 | ||
32 | bq25890 { | |
33 | compatible = "ti,bq25890"; | |
34 | reg = <0x6a>; | |
35 | ||
36 | ti,battery-regulation-voltage = <4200000>; | |
37 | ti,charge-current = <1000000>; | |
38 | ti,termination-current = <50000>; | |
39 | ti,precharge-current = <128000>; | |
40 | ti,minimum-sys-voltage = <3600000>; | |
41 | ti,boost-voltage = <5000000>; | |
42 | ti,boost-max-current = <1000000>; | |
43 | ||
44 | ti,use-ilim-pin; | |