thermal: export thermal_zone_parameters to sysfs
[deliverable/linux.git] / Documentation / thermal / sysfs-api.txt
CommitLineData
203d3d4a 1Generic Thermal Sysfs driver How To
38bb0849 2===================================
203d3d4a
ZR
3
4Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
5
6Updated: 2 January 2008
7
8Copyright (c) 2008 Intel Corporation
9
10
110. Introduction
12
38bb0849
FP
13The generic thermal sysfs provides a set of interfaces for thermal zone
14devices (sensors) and thermal cooling devices (fan, processor...) to register
15with the thermal management solution and to be a part of it.
203d3d4a 16
38bb0849
FP
17This how-to focuses on enabling new thermal zone and cooling devices to
18participate in thermal management.
19This solution is platform independent and any type of thermal zone devices
20and cooling devices should be able to make use of the infrastructure.
203d3d4a 21
38bb0849
FP
22The main task of the thermal sysfs driver is to expose thermal zone attributes
23as well as cooling device attributes to the user space.
24An intelligent thermal management application can make decisions based on
25inputs from thermal zone attributes (the current temperature and trip point
26temperature) and throttle appropriate devices.
203d3d4a
ZR
27
28[0-*] denotes any positive number starting from 0
29[1-*] denotes any positive number starting from 1
30
311. thermal sysfs driver interface functions
32
331.1 thermal zone device interface
514e6d20 341.1.1 struct thermal_zone_device *thermal_zone_device_register(char *type,
c56f5c03 35 int trips, int mask, void *devdata,
514e6d20
ZR
36 struct thermal_zone_device_ops *ops,
37 const struct thermal_zone_params *tzp,
38 int passive_delay, int polling_delay))
38bb0849
FP
39
40 This interface function adds a new thermal zone device (sensor) to
41 /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
42 thermal cooling devices registered at the same time.
43
514e6d20 44 type: the thermal zone type.
38bb0849 45 trips: the total number of trip points this thermal zone supports.
c56f5c03 46 mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
38bb0849
FP
47 devdata: device private data
48 ops: thermal zone device call-backs.
49 .bind: bind the thermal zone device with a thermal cooling device.
50 .unbind: unbind the thermal zone device with a thermal cooling device.
51 .get_temp: get the current temperature of the thermal zone.
8eaa8d6c
ZR
52 .get_mode: get the current mode (enabled/disabled) of the thermal zone.
53 - "enabled" means the kernel thermal management is enabled.
54 - "disabled" will prevent kernel thermal driver action upon trip points
38bb0849 55 so that user applications can take charge of thermal management.
8eaa8d6c 56 .set_mode: set the mode (enabled/disabled) of the thermal zone.
38bb0849
FP
57 .get_trip_type: get the type of certain trip point.
58 .get_trip_temp: get the temperature above which the certain trip point
59 will be fired.
e6e238c3
ADK
60 .set_emul_temp: set the emulation temperature which helps in debugging
61 different threshold temperature points.
514e6d20
ZR
62 tzp: thermal zone platform parameters.
63 passive_delay: number of milliseconds to wait between polls when
64 performing passive cooling.
65 polling_delay: number of milliseconds to wait between polls when checking
66 whether trip points have been crossed (0 for interrupt driven systems).
67
203d3d4a
ZR
68
691.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
70
38bb0849
FP
71 This interface function removes the thermal zone device.
72 It deletes the corresponding entry form /sys/class/thermal folder and
73 unbind all the thermal cooling devices it uses.
203d3d4a
ZR
74
751.2 thermal cooling device interface
761.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
38bb0849
FP
77 void *devdata, struct thermal_cooling_device_ops *)
78
79 This interface function adds a new thermal cooling device (fan/processor/...)
80 to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
81 to all the thermal zone devices register at the same time.
82 name: the cooling device name.
83 devdata: device private data.
84 ops: thermal cooling devices call-backs.
85 .get_max_state: get the Maximum throttle state of the cooling device.
86 .get_cur_state: get the Current throttle state of the cooling device.
87 .set_cur_state: set the Current throttle state of the cooling device.
203d3d4a
ZR
88
891.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
90
38bb0849
FP
91 This interface function remove the thermal cooling device.
92 It deletes the corresponding entry form /sys/class/thermal folder and
93 unbind itself from all the thermal zone devices using it.
203d3d4a
ZR
94
951.3 interface for binding a thermal zone device with a thermal cooling device
961.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
9d99842f 97 int trip, struct thermal_cooling_device *cdev,
6cd9e9f6 98 unsigned long upper, unsigned long lower, unsigned int weight);
203d3d4a 99
38bb0849
FP
100 This interface function bind a thermal cooling device to the certain trip
101 point of a thermal zone device.
102 This function is usually called in the thermal zone device .bind callback.
103 tz: the thermal zone device
104 cdev: thermal cooling device
105 trip: indicates which trip point the cooling devices is associated with
106 in this thermal zone.
9d99842f
ZR
107 upper:the Maximum cooling state for this trip point.
108 THERMAL_NO_LIMIT means no upper limit,
109 and the cooling device can be in max_state.
110 lower:the Minimum cooling state can be used for this trip point.
111 THERMAL_NO_LIMIT means no lower limit,
112 and the cooling device can be in cooling state 0.
6cd9e9f6
KS
113 weight: the influence of this cooling device in this thermal
114 zone. See 1.4.1 below for more information.
203d3d4a
ZR
115
1161.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
38bb0849 117 int trip, struct thermal_cooling_device *cdev);
203d3d4a 118
38bb0849
FP
119 This interface function unbind a thermal cooling device from the certain
120 trip point of a thermal zone device. This function is usually called in
121 the thermal zone device .unbind callback.
122 tz: the thermal zone device
123 cdev: thermal cooling device
124 trip: indicates which trip point the cooling devices is associated with
125 in this thermal zone.
203d3d4a 126
6ea083b1
D
1271.4 Thermal Zone Parameters
1281.4.1 struct thermal_bind_params
129 This structure defines the following parameters that are used to bind
130 a zone with a cooling device for a particular trip point.
131 .cdev: The cooling device pointer
bcdcbbc7
JM
132 .weight: The 'influence' of a particular cooling device on this
133 zone. This is relative to the rest of the cooling
134 devices. For example, if all cooling devices have a
135 weight of 1, then they all contribute the same. You can
136 use percentages if you want, but it's not mandatory. A
137 weight of 0 means that this cooling device doesn't
138 contribute to the cooling of this zone unless all cooling
139 devices have a weight of 0. If all weights are 0, then
140 they all contribute the same.
6ea083b1
D
141 .trip_mask:This is a bit mask that gives the binding relation between
142 this thermal zone and cdev, for a particular trip point.
143 If nth bit is set, then the cdev and thermal zone are bound
144 for trip point n.
a8892d83
EV
145 .limits: This is an array of cooling state limits. Must have exactly
146 2 * thermal_zone.number_of_trip_points. It is an array consisting
147 of tuples <lower-state upper-state> of state limits. Each trip
148 will be associated with one state limit tuple when binding.
149 A NULL pointer means <THERMAL_NO_LIMITS THERMAL_NO_LIMITS>
150 on all trips. These limits are used when binding a cdev to a
151 trip point.
6ea083b1
D
152 .match: This call back returns success(0) if the 'tz and cdev' need to
153 be bound, as per platform data.
1541.4.2 struct thermal_zone_params
155 This structure defines the platform level parameters for a thermal zone.
156 This data, for each thermal zone should come from the platform layer.
157 This is an optional feature where some platforms can choose not to
158 provide this data.
159 .governor_name: Name of the thermal governor used for this zone
ccba4ffd
EV
160 .no_hwmon: a boolean to indicate if the thermal to hwmon sysfs interface
161 is required. when no_hwmon == false, a hwmon sysfs interface
162 will be created. when no_hwmon == true, nothing will be done.
163 In case the thermal_zone_params is NULL, the hwmon interface
164 will be created (for backward compatibility).
6ea083b1
D
165 .num_tbps: Number of thermal_bind_params entries for this zone
166 .tbp: thermal_bind_params entries
167
203d3d4a
ZR
1682. sysfs attributes structure
169
170RO read only value
171RW read/write value
172
e9ae7107
ZR
173Thermal sysfs attributes will be represented under /sys/class/thermal.
174Hwmon sysfs I/F extension is also available under /sys/class/hwmon
175if hwmon is compiled in or built as a module.
203d3d4a
ZR
176
177Thermal zone device sys I/F, created once it's registered:
e9ae7107 178/sys/class/thermal/thermal_zone[0-*]:
38bb0849
FP
179 |---type: Type of the thermal zone
180 |---temp: Current temperature
181 |---mode: Working mode of the thermal zone
6ea083b1 182 |---policy: Thermal governor used for this zone
38bb0849
FP
183 |---trip_point_[0-*]_temp: Trip point temperature
184 |---trip_point_[0-*]_type: Trip point type
27365a6c 185 |---trip_point_[0-*]_hyst: Hysteresis value for this trip point
e6e238c3 186 |---emul_temp: Emulated temperature set node
9f38271c
JM
187 |---sustainable_power: Sustainable dissipatable power
188 |---k_po: Proportional term during temperature overshoot
189 |---k_pu: Proportional term during temperature undershoot
190 |---k_i: PID's integral term in the power allocator gov
191 |---k_d: PID's derivative term in the power allocator
192 |---integral_cutoff: Offset above which errors are accumulated
203d3d4a
ZR
193
194Thermal cooling device sys I/F, created once it's registered:
e9ae7107 195/sys/class/thermal/cooling_device[0-*]:
38bb0849
FP
196 |---type: Type of the cooling device(processor/fan/...)
197 |---max_state: Maximum cooling state of the cooling device
198 |---cur_state: Current cooling state of the cooling device
203d3d4a
ZR
199
200
38bb0849
FP
201Then next two dynamic attributes are created/removed in pairs. They represent
202the relationship between a thermal zone and its associated cooling device.
203They are created/removed for each successful execution of
204thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
203d3d4a 205
38bb0849
FP
206/sys/class/thermal/thermal_zone[0-*]:
207 |---cdev[0-*]: [0-*]th cooling device in current thermal zone
208 |---cdev[0-*]_trip_point: Trip point that cdev[0-*] is associated with
db916513
JM
209 |---cdev[0-*]_weight: Influence of the cooling device in
210 this thermal zone
203d3d4a 211
e9ae7107 212Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
38bb0849
FP
213the generic thermal driver also creates a hwmon sysfs I/F for each _type_
214of thermal zone device. E.g. the generic thermal driver registers one hwmon
215class device and build the associated hwmon sysfs I/F for all the registered
216ACPI thermal zones.
217
e9ae7107 218/sys/class/hwmon/hwmon[0-*]:
38bb0849
FP
219 |---name: The type of the thermal zone devices
220 |---temp[1-*]_input: The current temperature of thermal zone [1-*]
221 |---temp[1-*]_critical: The critical trip point of thermal zone [1-*]
222
e9ae7107 223Please read Documentation/hwmon/sysfs-interface for additional information.
203d3d4a
ZR
224
225***************************
226* Thermal zone attributes *
227***************************
228
38bb0849
FP
229type
230 Strings which represent the thermal zone type.
231 This is given by thermal zone driver as part of registration.
232 E.g: "acpitz" indicates it's an ACPI thermal device.
233 In order to keep it consistent with hwmon sys attribute; this should
234 be a short, lowercase string, not containing spaces nor dashes.
235 RO, Required
236
237temp
238 Current temperature as reported by thermal zone (sensor).
239 Unit: millidegree Celsius
240 RO, Required
241
242mode
8eaa8d6c 243 One of the predefined values in [enabled, disabled].
38bb0849
FP
244 This file gives information about the algorithm that is currently
245 managing the thermal zone. It can be either default kernel based
246 algorithm or user space application.
8eaa8d6c
ZR
247 enabled = enable Kernel Thermal management.
248 disabled = Preventing kernel thermal zone driver actions upon
249 trip points so that user application can take full
250 charge of the thermal management.
38bb0849
FP
251 RW, Optional
252
6ea083b1
D
253policy
254 One of the various thermal governors used for a particular zone.
255 RW, Required
256
38bb0849
FP
257trip_point_[0-*]_temp
258 The temperature above which trip point will be fired.
259 Unit: millidegree Celsius
260 RO, Optional
261
262trip_point_[0-*]_type
263 Strings which indicate the type of the trip point.
264 E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
265 thermal zone.
266 RO, Optional
267
27365a6c
D
268trip_point_[0-*]_hyst
269 The hysteresis value for a trip point, represented as an integer
270 Unit: Celsius
271 RW, Optional
272
38bb0849
FP
273cdev[0-*]
274 Sysfs link to the thermal cooling device node where the sys I/F
275 for cooling device throttling control represents.
276 RO, Optional
277
278cdev[0-*]_trip_point
279 The trip point with which cdev[0-*] is associated in this thermal
280 zone; -1 means the cooling device is not associated with any trip
281 point.
282 RO, Optional
29226ed3 283
db916513
JM
284cdev[0-*]_weight
285 The influence of cdev[0-*] in this thermal zone. This value
286 is relative to the rest of cooling devices in the thermal
287 zone. For example, if a cooling device has a weight double
288 than that of other, it's twice as effective in cooling the
289 thermal zone.
290 RW, Optional
291
29226ed3
FP
292passive
293 Attribute is only present for zones in which the passive cooling
294 policy is not supported by native thermal driver. Default is zero
295 and can be set to a temperature (in millidegrees) to enable a
296 passive trip point for the zone. Activation is done by polling with
297 an interval of 1 second.
298 Unit: millidegrees Celsius
3d8e3ad8 299 Valid values: 0 (disabled) or greater than 1000
29226ed3 300 RW, Optional
38bb0849 301
e6e238c3
ADK
302emul_temp
303 Interface to set the emulated temperature method in thermal zone
304 (sensor). After setting this temperature, the thermal zone may pass
305 this temperature to platform emulation function if registered or
306 cache it locally. This is useful in debugging different temperature
307 threshold and its associated cooling action. This is write only node
308 and writing 0 on this node should disable emulation.
309 Unit: millidegree Celsius
310 WO, Optional
311
8837295a
EV
312 WARNING: Be careful while enabling this option on production systems,
313 because userland can easily disable the thermal policy by simply
314 flooding this sysfs node with low temperature values.
315
9f38271c
JM
316sustainable_power
317 An estimate of the sustained power that can be dissipated by
318 the thermal zone. Used by the power allocator governor. For
319 more information see Documentation/thermal/power_allocator.txt
320 Unit: milliwatts
321 RW, Optional
322
323k_po
324 The proportional term of the power allocator governor's PID
325 controller during temperature overshoot. Temperature overshoot
326 is when the current temperature is above the "desired
327 temperature" trip point. For more information see
328 Documentation/thermal/power_allocator.txt
329 RW, Optional
330
331k_pu
332 The proportional term of the power allocator governor's PID
333 controller during temperature undershoot. Temperature undershoot
334 is when the current temperature is below the "desired
335 temperature" trip point. For more information see
336 Documentation/thermal/power_allocator.txt
337 RW, Optional
338
339k_i
340 The integral term of the power allocator governor's PID
341 controller. This term allows the PID controller to compensate
342 for long term drift. For more information see
343 Documentation/thermal/power_allocator.txt
344 RW, Optional
345
346k_d
347 The derivative term of the power allocator governor's PID
348 controller. For more information see
349 Documentation/thermal/power_allocator.txt
350 RW, Optional
351
352integral_cutoff
353 Temperature offset from the desired temperature trip point
354 above which the integral term of the power allocator
355 governor's PID controller starts accumulating errors. For
356 example, if integral_cutoff is 0, then the integral term only
357 accumulates error when temperature is above the desired
358 temperature trip point. For more information see
359 Documentation/thermal/power_allocator.txt
360 RW, Optional
361
38bb0849
FP
362*****************************
363* Cooling device attributes *
364*****************************
365
366type
367 String which represents the type of device, e.g:
368 - for generic ACPI: should be "Fan", "Processor" or "LCD"
369 - for memory controller device on intel_menlow platform:
370 should be "Memory controller".
371 RO, Required
372
373max_state
374 The maximum permissible cooling state of this cooling device.
375 RO, Required
376
377cur_state
378 The current cooling state of this cooling device.
379 The value can any integer numbers between 0 and max_state:
380 - cur_state == 0 means no cooling
381 - cur_state == max_state means the maximum cooling.
382 RW, Required
203d3d4a
ZR
383
3843. A simple implementation
385
38bb0849
FP
386ACPI thermal zone may support multiple trip points like critical, hot,
387passive, active. If an ACPI thermal zone supports critical, passive,
388active[0] and active[1] at the same time, it may register itself as a
389thermal_zone_device (thermal_zone1) with 4 trip points in all.
390It has one processor and one fan, which are both registered as
db916513
JM
391thermal_cooling_device. Both are considered to have the same
392effectiveness in cooling the thermal zone.
38bb0849
FP
393
394If the processor is listed in _PSL method, and the fan is listed in _AL0
395method, the sys I/F structure will be built like this:
203d3d4a
ZR
396
397/sys/class/thermal:
398
399|thermal_zone1:
38bb0849
FP
400 |---type: acpitz
401 |---temp: 37000
8eaa8d6c 402 |---mode: enabled
6ea083b1 403 |---policy: step_wise
38bb0849
FP
404 |---trip_point_0_temp: 100000
405 |---trip_point_0_type: critical
406 |---trip_point_1_temp: 80000
407 |---trip_point_1_type: passive
408 |---trip_point_2_temp: 70000
409 |---trip_point_2_type: active0
410 |---trip_point_3_temp: 60000
411 |---trip_point_3_type: active1
412 |---cdev0: --->/sys/class/thermal/cooling_device0
413 |---cdev0_trip_point: 1 /* cdev0 can be used for passive */
db916513 414 |---cdev0_weight: 1024
38bb0849
FP
415 |---cdev1: --->/sys/class/thermal/cooling_device3
416 |---cdev1_trip_point: 2 /* cdev1 can be used for active[0]*/
db916513 417 |---cdev1_weight: 1024
203d3d4a
ZR
418
419|cooling_device0:
38bb0849
FP
420 |---type: Processor
421 |---max_state: 8
422 |---cur_state: 0
203d3d4a
ZR
423
424|cooling_device3:
38bb0849
FP
425 |---type: Fan
426 |---max_state: 2
427 |---cur_state: 0
e9ae7107
ZR
428
429/sys/class/hwmon:
430
431|hwmon0:
38bb0849
FP
432 |---name: acpitz
433 |---temp1_input: 37000
434 |---temp1_crit: 100000
4cb18728
D
435
4364. Event Notification
437
438The framework includes a simple notification mechanism, in the form of a
439netlink event. Netlink socket initialization is done during the _init_
440of the framework. Drivers which intend to use the notification mechanism
2d58d7ea 441just need to call thermal_generate_netlink_event() with two arguments viz
8ab3e6a0
EV
442(originator, event). The originator is a pointer to struct thermal_zone_device
443from where the event has been originated. An integer which represents the
444thermal zone device will be used in the message to identify the zone. The
4cb18728
D
445event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
446THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
447crosses any of the configured thresholds.
6ea083b1
D
448
4495. Export Symbol APIs:
450
4515.1: get_tz_trend:
452This function returns the trend of a thermal zone, i.e the rate of change
453of temperature of the thermal zone. Ideally, the thermal sensor drivers
454are supposed to implement the callback. If they don't, the thermal
455framework calculated the trend by comparing the previous and the current
456temperature values.
457
4585.2:get_thermal_instance:
459This function returns the thermal_instance corresponding to a given
460{thermal_zone, cooling_device, trip_point} combination. Returns NULL
461if such an instance does not exist.
462
7b73c993 4635.3:thermal_notify_framework:
6ea083b1
D
464This function handles the trip events from sensor drivers. It starts
465throttling the cooling devices according to the policy configured.
466For CRITICAL and HOT trip points, this notifies the respective drivers,
467and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
468The throttling policy is based on the configured platform data; if no
469platform data is provided, this uses the step_wise throttling policy.
470
4715.4:thermal_cdev_update:
472This function serves as an arbitrator to set the state of a cooling
473device. It sets the cooling device to the deepest cooling state if
474possible.
This page took 0.486013 seconds and 5 git commands to generate.