Merge remote-tracking branch 'iommu/next'
[deliverable/linux.git] / Documentation / devicetree / bindings / clock / sunxi-ccu.txt
1 Allwinner Clock Control Unit Binding
2 ------------------------------------
3
4 Required properties :
5 - compatible: must contain one of the following compatibles:
6 - "allwinner,sun6i-a31-ccu"
7 - "allwinner,sun8i-a23-ccu"
8 - "allwinner,sun8i-a33-ccu"
9 - "allwinner,sun8i-h3-ccu"
10
11 - reg: Must contain the registers base address and length
12 - clocks: phandle to the oscillators feeding the CCU. Two are needed:
13 - "hosc": the high frequency oscillator (usually at 24MHz)
14 - "losc": the low frequency oscillator (usually at 32kHz)
15 - clock-names: Must contain the clock names described just above
16 - #clock-cells : must contain 1
17 - #reset-cells : must contain 1
18
19 Example:
20 ccu: clock@01c20000 {
21 compatible = "allwinner,sun8i-h3-ccu";
22 reg = <0x01c20000 0x400>;
23 clocks = <&osc24M>, <&osc32k>;
24 clock-names = "hosc", "losc";
25 #clock-cells = <1>;
26 #reset-cells = <1>;
27 };
This page took 0.031838 seconds and 5 git commands to generate.