drm/i915: Check VBT for eDP ports on VLV
authorVille Syrjälä <ville.syrjala@linux.intel.com>
Fri, 1 Nov 2013 16:22:39 +0000 (18:22 +0200)
committerDaniel Vetter <daniel.vetter@ffwll.ch>
Thu, 28 Nov 2013 12:42:12 +0000 (13:42 +0100)
commit5d8a77529bd6864361005117c3a611b6d810aa77
tree488b67b585fa92e8e53fcb7d16400d1f00948941
parentfec8cba306f974f3a4491176994de5d821273643
drm/i915: Check VBT for eDP ports on VLV

VLV can have eDP on either port B or C, or even both. Based on the
VBT spec, intel_dpd_is_edp() should work on VLV too, assuming we
check the correct ports.

So instead of hardcoding port D, rename the function to
intel_dp_is_edp() and pass the port as a parameter, and use it
on VLV ports B and C.

Bugzilla: https://bugs.freedesktop.org/show_bug.cgi?id=71051
Tested-by: Robert Hooker <robert.hooker@canonical.com>
Signed-off-by: Ville Syrjälä <ville.syrjala@linux.intel.com>
Reviewed-by: Jesse Barnes <jbarnes@virtuousgeek.org>
[danvet: Wrestle the patch to apply and compile properly.]
Signed-off-by: Daniel Vetter <daniel.vetter@ffwll.ch>
drivers/gpu/drm/i915/intel_ddi.c
drivers/gpu/drm/i915/intel_display.c
drivers/gpu/drm/i915/intel_dp.c
drivers/gpu/drm/i915/intel_drv.h
This page took 0.027397 seconds and 5 git commands to generate.