Fix: Off by one in seq num for data pending command
[lttng-tools.git] / src / common / consumer.c
index be984a49270fefbba0b55bccd8ebf897ceea4ce7..61d6f2e79b702337e3e8095da5132136714616b5 100644 (file)
@@ -782,6 +782,13 @@ static int write_relayd_stream_header(struct lttng_consumer_stream *stream,
                data_hdr.stream_id = htobe64(stream->relayd_stream_id);
                data_hdr.data_size = htobe32(data_size);
                data_hdr.padding_size = htobe32(padding);
+               /*
+                * Note that net_seq_num below is assigned with the *current* value of
+                * next_net_seq_num and only after that the next_net_seq_num will be
+                * increment. This is why when issuing a command on the relayd using
+                * this next value, 1 should always be substracted in order to compare
+                * the last seen sequence number on the relayd side to the last sent.
+                */
                data_hdr.net_seq_num = htobe64(stream->next_net_seq_num++);
                /* Other fields are zeroed previously */
 
@@ -3021,7 +3028,8 @@ int consumer_data_pending(uint64_t id)
                                                stream->relayd_stream_id);
                        } else {
                                ret = relayd_data_pending(&relayd->control_sock,
-                                               stream->relayd_stream_id, stream->next_net_seq_num);
+                                               stream->relayd_stream_id,
+                                               stream->next_net_seq_num - 1);
                        }
                        pthread_mutex_unlock(&relayd->ctrl_sock_mutex);
                        if (ret == 1) {
This page took 0.024079 seconds and 5 git commands to generate.