Merge remote-tracking branch 'mtd/master'
[deliverable/linux.git] / drivers / thermal / Kconfig
CommitLineData
203d3d4a
ZR
1#
2# Generic thermal sysfs drivers configuration
3#
4
5menuconfig THERMAL
63c4ec90 6 tristate "Generic Thermal sysfs driver"
203d3d4a
ZR
7 help
8 Generic Thermal Sysfs driver offers a generic mechanism for
9 thermal management. Usually it's made up of one or more thermal
10 zone and cooling device.
543a9561 11 Each thermal zone contains its own temperature, trip points,
203d3d4a
ZR
12 cooling devices.
13 All platforms with ACPI thermal support can use this driver.
63c4ec90 14 If you want this support, you should say Y or M here.
16d75239 15
72e19897
ZR
16if THERMAL
17
16d75239 18config THERMAL_HWMON
ab92402a 19 bool
0dd88793 20 prompt "Expose thermal sensors as hwmon device"
16d75239 21 depends on HWMON=y || HWMON=THERMAL
ab92402a 22 default y
0dd88793
EV
23 help
24 In case a sensor is registered with the thermal
25 framework, this option will also register it
26 as a hwmon. The sensor will then have the common
27 hwmon sysfs interface.
28
29 Say 'Y' here if you want all thermal sensors to
30 have hwmon sysfs interface too.
6a92c366 31
4e5e4705
EV
32config THERMAL_OF
33 bool
34 prompt "APIs to parse thermal data out of device tree"
35 depends on OF
36 default y
37 help
38 This options provides helpers to add the support to
39 read and parse thermal data definitions out of the
40 device tree blob.
41
42 Say 'Y' here if you need to build thermal infrastructure
43 based on device tree.
44
35e94644
PA
45config THERMAL_WRITABLE_TRIPS
46 bool "Enable writable trip points"
47 help
48 This option allows the system integrator to choose whether
49 trip temperatures can be changed from userspace. The
50 writable trips need to be specified when setting up the
51 thermal zone but the choice here takes precedence.
52
53 Say 'Y' here if you would like to allow userspace tools to
54 change trip temperatures.
55
72e19897
ZR
56choice
57 prompt "Default Thermal governor"
58 default THERMAL_DEFAULT_GOV_STEP_WISE
59 help
60 This option sets which thermal governor shall be loaded at
61 startup. If in doubt, select 'step_wise'.
62
63config THERMAL_DEFAULT_GOV_STEP_WISE
64 bool "step_wise"
9d185d04 65 select THERMAL_GOV_STEP_WISE
72e19897
ZR
66 help
67 Use the step_wise governor as default. This throttles the
68 devices one step at a time.
69
70config THERMAL_DEFAULT_GOV_FAIR_SHARE
71 bool "fair_share"
9d185d04 72 select THERMAL_GOV_FAIR_SHARE
72e19897
ZR
73 help
74 Use the fair_share governor as default. This throttles the
75 devices based on their 'contribution' to a zone. The
76 contribution should be provided through platform data.
77
78config THERMAL_DEFAULT_GOV_USER_SPACE
79 bool "user_space"
9d185d04 80 select THERMAL_GOV_USER_SPACE
72e19897
ZR
81 help
82 Select this if you want to let the user space manage the
ece238fe 83 platform thermals.
72e19897 84
6b775e87
JM
85config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
86 bool "power_allocator"
87 select THERMAL_GOV_POWER_ALLOCATOR
88 help
89 Select this if you want to control temperature based on
90 system and device power allocation. This governor can only
91 operate on cooling devices that implement the power API.
92
72e19897
ZR
93endchoice
94
9d185d04 95config THERMAL_GOV_FAIR_SHARE
72e19897
ZR
96 bool "Fair-share thermal governor"
97 help
98 Enable this to manage platform thermals using fair-share governor.
99
9d185d04 100config THERMAL_GOV_STEP_WISE
72e19897
ZR
101 bool "Step_wise thermal governor"
102 help
103 Enable this to manage platform thermals using a simple linear
a8227948 104 governor.
72e19897 105
e4dbf98f
PF
106config THERMAL_GOV_BANG_BANG
107 bool "Bang Bang thermal governor"
108 default n
109 help
110 Enable this to manage platform thermals using bang bang governor.
111
112 Say 'Y' here if you want to use two point temperature regulation
113 used for fans without throttling. Some fan drivers depend on this
114 governor to be enabled (e.g. acerhdf).
115
9d185d04 116config THERMAL_GOV_USER_SPACE
72e19897
ZR
117 bool "User_space thermal governor"
118 help
119 Enable this to let the user space manage the platform thermals.
120
6b775e87
JM
121config THERMAL_GOV_POWER_ALLOCATOR
122 bool "Power allocator thermal governor"
6b775e87
JM
123 help
124 Enable this to manage platform thermals by dynamically
125 allocating and limiting power to devices.
126
02361418 127config CPU_THERMAL
bbf7fc88 128 bool "generic cpu cooling support"
72e19897 129 depends on CPU_FREQ
39d99cff 130 depends on THERMAL_OF
02361418
ADK
131 help
132 This implements the generic cpu cooling mechanism through frequency
f7188b3d
EV
133 reduction. An ACPI version of this already exists
134 (drivers/acpi/processor_thermal.c).
02361418
ADK
135 This will be useful for platforms using the generic thermal interface
136 and not the ACPI interface.
f7188b3d 137
02361418
ADK
138 If you want this support, you should say Y here.
139
f9df89d8
EV
140config CLOCK_THERMAL
141 bool "Generic clock cooling support"
142 depends on COMMON_CLK
143 depends on PM_OPP
144 help
145 This entry implements the generic clock cooling mechanism through
146 frequency clipping. Typically used to cool off co-processors. The
147 device that is configured to use this cooling mechanism will be
148 controlled to reduce clock frequency whenever temperature is high.
149
a76caf55
ØE
150config DEVFREQ_THERMAL
151 bool "Generic device cooling support"
152 depends on PM_DEVFREQ
153 depends on PM_OPP
154 help
155 This implements the generic devfreq cooling mechanism through
156 frequency reduction for devices using devfreq.
157
158 This will throttle the device by limiting the maximum allowed DVFS
159 frequency corresponding to the cooling level.
160
161 In order to use the power extensions of the cooling device,
162 devfreq should use the simple_ondemand governor.
163
f9df89d8
EV
164 If you want this support, you should say Y here.
165
e6e238c3
ADK
166config THERMAL_EMULATION
167 bool "Thermal emulation mode support"
168 help
169 Enable this option to make a emul_temp sysfs node in thermal zone
170 directory to support temperature emulation. With emulation sysfs node,
171 user can manually input temperature and test the different trip
172 threshold behaviour for simulation purpose.
173
8837295a
EV
174 WARNING: Be careful while enabling this option on production systems,
175 because userland can easily disable the thermal policy by simply
176 flooding this sysfs node with low temperature values.
177
9a5238a9 178config HISI_THERMAL
179 tristate "Hisilicon thermal driver"
f9e2b052 180 depends on (ARCH_HISI && CPU_THERMAL && OF) || COMPILE_TEST
bf82c350 181 depends on HAS_IOMEM
9a5238a9 182 help
183 Enable this to plug hisilicon's thermal sensor driver into the Linux
184 thermal framework. cpufreq is used as the cooling device to throttle
185 CPUs when the passive trip is crossed.
186
ca3de46b
SG
187config IMX_THERMAL
188 tristate "Temperature sensor driver for Freescale i.MX SoCs"
a5ecf8cb 189 depends on (ARCH_MXC && CPU_THERMAL) || COMPILE_TEST
ca3de46b
SG
190 depends on MFD_SYSCON
191 depends on OF
192 help
193 Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
194 It supports one critical trip point and one passive trip point. The
195 cpufreq is used as the cooling device to throttle CPUs when the
196 passive trip is crossed.
197
bcafb8ec
LD
198config MAX77620_THERMAL
199 tristate "Temperature sensor driver for Maxim MAX77620 PMIC"
200 depends on MFD_MAX77620
201 depends on OF
202 help
203 Support for die junction temperature warning alarm for Maxim
204 Semiconductor PMIC MAX77620 device. Device generates two alarm
205 interrupts when PMIC die temperature cross the threshold of
206 120 degC and 140 degC.
207
1b9e177e
JH
208config QORIQ_THERMAL
209 tristate "QorIQ Thermal Monitoring Unit"
210 depends on THERMAL_OF
211 depends on HAS_IOMEM
212 help
213 Support for Thermal Monitoring Unit (TMU) found on QorIQ platforms.
214 It supports one critical trip point and one passive trip point. The
215 cpufreq is used as the cooling device to throttle CPUs when the
216 passive trip is crossed.
217
6a92c366 218config SPEAR_THERMAL
4d2f1794 219 tristate "SPEAr thermal sensor driver"
aa2937b7 220 depends on PLAT_SPEAR || COMPILE_TEST
bf82c350 221 depends on HAS_IOMEM
b9c7aff4 222 depends on OF
6a92c366
VF
223 help
224 Enable this to plug the SPEAr thermal sensor driver into the Linux
a8227948 225 thermal framework.
1e426ffd 226
cbac8f63
CW
227config ROCKCHIP_THERMAL
228 tristate "Rockchip thermal driver"
444f9b00 229 depends on ARCH_ROCKCHIP || COMPILE_TEST
cbac8f63 230 depends on RESET_CONTROLLER
bf82c350 231 depends on HAS_IOMEM
cbac8f63
CW
232 help
233 Rockchip thermal driver provides support for Temperature sensor
234 ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
235 trip point. Cpufreq is used as the cooling device and will throttle
236 CPUs when the Temperature crosses the passive trip point.
237
1e426ffd
KM
238config RCAR_THERMAL
239 tristate "Renesas R-Car thermal driver"
8255e4e2 240 depends on ARCH_RENESAS || COMPILE_TEST
d1c8b041 241 depends on HAS_IOMEM
1e426ffd
KM
242 help
243 Enable this to plug the R-Car thermal sensor driver into the Linux
a8227948 244 thermal framework.
c48cbba6 245
7060aa36
NI
246config KIRKWOOD_THERMAL
247 tristate "Temperature sensor on Marvell Kirkwood SoCs"
9c8aa959 248 depends on MACH_KIRKWOOD || COMPILE_TEST
bf82c350 249 depends on HAS_IOMEM
7060aa36
NI
250 depends on OF
251 help
252 Support for the Kirkwood thermal sensor driver into the Linux thermal
253 framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
254
74ffa64c
AL
255config DOVE_THERMAL
256 tristate "Temperature sensor on Marvell Dove SoCs"
07fffd5c 257 depends on ARCH_DOVE || MACH_DOVE || COMPILE_TEST
bf82c350 258 depends on HAS_IOMEM
74ffa64c
AL
259 depends on OF
260 help
261 Support for the Dove thermal sensor driver in the Linux thermal
262 framework.
263
aa1acb04 264config DB8500_THERMAL
26716ce1
AB
265 tristate "DB8500 thermal management"
266 depends on MFD_DB8500_PRCMU
aa1acb04 267 default y
268 help
269 Adds DB8500 thermal management implementation according to the thermal
270 management framework. A thermal zone with several trip points will be
271 created. Cooling devices can be bound to the trip points to cool this
272 thermal zone if trip points reached.
273
fa0d654c
EG
274config ARMADA_THERMAL
275 tristate "Armada 370/XP thermal management"
1b158267 276 depends on ARCH_MVEBU || COMPILE_TEST
bf82c350 277 depends on HAS_IOMEM
fa0d654c
EG
278 depends on OF
279 help
280 Enable this option if you want to have support for thermal management
281 controller present in Armada 370 and Armada XP SoC.
282
aa1acb04 283config DB8500_CPUFREQ_COOLING
284 tristate "DB8500 cpufreq cooling"
527860fe 285 depends on ARCH_U8500 || COMPILE_TEST
bf82c350 286 depends on HAS_IOMEM
aa1acb04 287 depends on CPU_THERMAL
288 default y
289 help
290 Adds DB8500 cpufreq cooling devices, and these cooling devices can be
291 bound to thermal zone trip points. When a trip point reached, the
292 bound cpufreq cooling device turns active to set CPU frequency low to
293 cool down the CPU.
a56757af 294
d6d71ee4
JP
295config INTEL_POWERCLAMP
296 tristate "Intel PowerClamp idle injection driver"
297 depends on THERMAL
298 depends on X86
299 depends on CPU_SUP_INTEL
300 help
301 Enable this to enable Intel PowerClamp idle injection driver. This
302 enforce idle time which results in more package C-state residency. The
303 user interface is exposed via generic thermal framework.
304
f1a18a10
SP
305config X86_PKG_TEMP_THERMAL
306 tristate "X86 package temperature thermal driver"
b3ba0206 307 depends on X86_THERMAL_VECTOR
f1a18a10 308 select THERMAL_GOV_USER_SPACE
98cadf25 309 select THERMAL_WRITABLE_TRIPS
f1a18a10
SP
310 default m
311 help
312 Enable this to register CPU digital sensor for package temperature as
313 thermal zone. Each package will have its own thermal zone. There are
314 two trip points which can be set by user to get notifications via thermal
315 notification methods.
316
ee073604
SP
317config INTEL_SOC_DTS_IOSF_CORE
318 tristate
319 depends on X86
320 select IOSF_MBI
321 help
322 This is becoming a common feature for Intel SoCs to expose the additional
323 digital temperature sensors (DTSs) using side band interface (IOSF). This
324 implements the common set of helper functions to register, get temperature
325 and get/set thresholds on DTSs.
326
bc40b5e3
SP
327config INTEL_SOC_DTS_THERMAL
328 tristate "Intel SoCs DTS thermal driver"
3a2419f8
SP
329 depends on X86
330 select INTEL_SOC_DTS_IOSF_CORE
98cadf25 331 select THERMAL_WRITABLE_TRIPS
bc40b5e3
SP
332 help
333 Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
334 temperature sensor (DTS). These SoCs have two additional DTSs in
335 addition to DTSs on CPU cores. Each DTS will be registered as a
336 thermal zone. There are two trip points. One of the trip point can
337 be set by user mode programs to get notifications via Linux thermal
338 notification methods.The other trip is a critical trip point, which
339 was set by the driver based on the TJ MAX temperature.
340
8c187693
OBL
341config INTEL_QUARK_DTS_THERMAL
342 tristate "Intel Quark DTS thermal driver"
343 depends on X86_INTEL_QUARK
344 help
345 Enable this to register Intel Quark SoC (e.g. X1000) platform digital
346 temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
347 The DTS will be registered as a thermal zone. There are two trip points:
348 hot & critical. The critical trip point default value is set by
349 underlying BIOS/Firmware.
350
a3c89334
AL
351menu "ACPI INT340X thermal drivers"
352source drivers/thermal/int340x_thermal/Kconfig
353endmenu
52b1c69d 354
b474303f
BG
355config INTEL_BXT_PMIC_THERMAL
356 tristate "Intel Broxton PMIC thermal driver"
357 depends on X86 && INTEL_SOC_PMIC && REGMAP
358 help
359 Select this driver for Intel Broxton PMIC with ADC channels monitoring
360 system temperature measurements and alerts.
361 This driver is used for monitoring the ADC channels of PMIC and handles
362 the alert trip point interrupts and notifies the thermal framework with
363 the trip point and temperature details of the zone.
364
d0a12625
TD
365config INTEL_PCH_THERMAL
366 tristate "Intel PCH Thermal Reporting Driver"
367 depends on X86 && PCI
368 help
369 Enable this to support thermal reporting on certain intel PCHs.
370 Thermal reporting device will provide temperature reading,
371 programmable trip points and other information.
372
a92db1c8
SH
373config MTK_THERMAL
374 tristate "Temperature sensor driver for mediatek SoCs"
375 depends on ARCH_MEDIATEK || COMPILE_TEST
74e5053c 376 depends on HAS_IOMEM
62e14f6f 377 depends on NVMEM || NVMEM=n
a6f4850d 378 depends on RESET_CONTROLLER
a92db1c8
SH
379 default y
380 help
381 Enable this option if you want to have support for thermal management
382 controller present in Mediatek SoCs
383
eb982001 384menu "Texas Instruments thermal drivers"
ec2feb47 385depends on ARCH_HAS_BANDGAP || COMPILE_TEST
bf82c350 386depends on HAS_IOMEM
eb982001
EV
387source "drivers/thermal/ti-soc-thermal/Kconfig"
388endmenu
f157f596 389
c6821378 390menu "Samsung thermal drivers"
2bf42735 391depends on ARCH_EXYNOS || COMPILE_TEST
c6821378
ADK
392source "drivers/thermal/samsung/Kconfig"
393endmenu
394
60aef7ce
LJ
395menu "STMicroelectronics thermal drivers"
396depends on ARCH_STI && OF
397source "drivers/thermal/st/Kconfig"
398endmenu
399
0b58c08b
MG
400config TANGO_THERMAL
401 tristate "Tango thermal management"
402 depends on ARCH_TANGO || COMPILE_TEST
403 help
404 Enable the Tango thermal driver, which supports the primitive
405 temperature sensor embedded in Tango chips since the SMP8758.
406 This sensor only generates a 1-bit signal to indicate whether
407 the die temperature exceeds a programmable threshold.
408
a4dff94f
WN
409source "drivers/thermal/tegra/Kconfig"
410
c610afaa
II
411config QCOM_SPMI_TEMP_ALARM
412 tristate "Qualcomm SPMI PMIC Temperature Alarm"
e4217468 413 depends on OF && SPMI && IIO
c610afaa
II
414 select REGMAP_SPMI
415 help
416 This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
417 PMIC devices. It shows up in sysfs as a thermal sensor with multiple
418 trip points. The temperature reported by the thermal sensor reflects the
419 real time die temperature if an ADC is present or an estimate of the
420 temperature based upon the over temperature stage value.
421
b3aef78f
LD
422config GENERIC_ADC_THERMAL
423 tristate "Generic ADC based thermal sensor"
424 depends on IIO
425 help
426 This enabled a thermal sysfs driver for the temperature sensor
427 which is connected to the General Purpose ADC. The ADC channel
428 is read via IIO framework and the channel information is provided
429 to this driver. This driver reports the temperature by reading ADC
430 channel and converts it to temperature based on lookup table.
431
7589699c
RN
432menu "Qualcomm thermal drivers"
433depends on (ARCH_QCOM && OF) || COMPILE_TEST
434source "drivers/thermal/qcom/Kconfig"
435endmenu
436
72e19897 437endif