| 1 | /* |
| 2 | * field-types.c |
| 3 | * |
| 4 | * Babeltrace CTF IR - Event Types |
| 5 | * |
| 6 | * Copyright 2013, 2014 Jérémie Galarneau <jeremie.galarneau@efficios.com> |
| 7 | * |
| 8 | * Author: Jérémie Galarneau <jeremie.galarneau@efficios.com> |
| 9 | * |
| 10 | * Permission is hereby granted, free of charge, to any person obtaining a copy |
| 11 | * of this software and associated documentation files (the "Software"), to deal |
| 12 | * in the Software without restriction, including without limitation the rights |
| 13 | * to use, copy, modify, merge, publish, distribute, sublicense, and/or sell |
| 14 | * copies of the Software, and to permit persons to whom the Software is |
| 15 | * furnished to do so, subject to the following conditions: |
| 16 | * |
| 17 | * The above copyright notice and this permission notice shall be included in |
| 18 | * all copies or substantial portions of the Software. |
| 19 | * |
| 20 | * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR |
| 21 | * IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, |
| 22 | * FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE |
| 23 | * AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER |
| 24 | * LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, |
| 25 | * OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE |
| 26 | * SOFTWARE. |
| 27 | */ |
| 28 | |
| 29 | #define BT_LOG_TAG "FIELD-TYPES" |
| 30 | #include <babeltrace/lib-logging-internal.h> |
| 31 | |
| 32 | #include <babeltrace/ctf-ir/field-types-internal.h> |
| 33 | #include <babeltrace/ctf-ir/field-path-internal.h> |
| 34 | #include <babeltrace/ctf-ir/utils.h> |
| 35 | #include <babeltrace/ref.h> |
| 36 | #include <babeltrace/ctf-ir/clock-class.h> |
| 37 | #include <babeltrace/ctf-ir/clock-class-internal.h> |
| 38 | #include <babeltrace/ctf-writer/writer-internal.h> |
| 39 | #include <babeltrace/object-internal.h> |
| 40 | #include <babeltrace/ref.h> |
| 41 | #include <babeltrace/compiler-internal.h> |
| 42 | #include <babeltrace/endian-internal.h> |
| 43 | #include <babeltrace/assert-internal.h> |
| 44 | #include <float.h> |
| 45 | #include <inttypes.h> |
| 46 | #include <stdlib.h> |
| 47 | |
| 48 | struct range_overlap_query { |
| 49 | union { |
| 50 | uint64_t _unsigned; |
| 51 | int64_t _signed; |
| 52 | } range_start; |
| 53 | |
| 54 | union { |
| 55 | uint64_t _unsigned; |
| 56 | int64_t _signed; |
| 57 | } range_end; |
| 58 | int overlaps; |
| 59 | GQuark mapping_name; |
| 60 | }; |
| 61 | |
| 62 | static |
| 63 | void bt_field_type_destroy(struct bt_object *); |
| 64 | static |
| 65 | void bt_field_type_integer_destroy(struct bt_field_type *); |
| 66 | static |
| 67 | void bt_field_type_enumeration_destroy(struct bt_field_type *); |
| 68 | static |
| 69 | void bt_field_type_floating_point_destroy(struct bt_field_type *); |
| 70 | static |
| 71 | void bt_field_type_structure_destroy(struct bt_field_type *); |
| 72 | static |
| 73 | void bt_field_type_variant_destroy(struct bt_field_type *); |
| 74 | static |
| 75 | void bt_field_type_array_destroy(struct bt_field_type *); |
| 76 | static |
| 77 | void bt_field_type_sequence_destroy(struct bt_field_type *); |
| 78 | static |
| 79 | void bt_field_type_string_destroy(struct bt_field_type *); |
| 80 | |
| 81 | static |
| 82 | void (* const type_destroy_funcs[])(struct bt_field_type *) = { |
| 83 | [BT_FIELD_TYPE_ID_INTEGER] = bt_field_type_integer_destroy, |
| 84 | [BT_FIELD_TYPE_ID_ENUM] = |
| 85 | bt_field_type_enumeration_destroy, |
| 86 | [BT_FIELD_TYPE_ID_FLOAT] = |
| 87 | bt_field_type_floating_point_destroy, |
| 88 | [BT_FIELD_TYPE_ID_STRUCT] = bt_field_type_structure_destroy, |
| 89 | [BT_FIELD_TYPE_ID_VARIANT] = bt_field_type_variant_destroy, |
| 90 | [BT_FIELD_TYPE_ID_ARRAY] = bt_field_type_array_destroy, |
| 91 | [BT_FIELD_TYPE_ID_SEQUENCE] = bt_field_type_sequence_destroy, |
| 92 | [BT_FIELD_TYPE_ID_STRING] = bt_field_type_string_destroy, |
| 93 | }; |
| 94 | |
| 95 | static |
| 96 | void generic_field_type_freeze(struct bt_field_type *); |
| 97 | static |
| 98 | void bt_field_type_integer_freeze(struct bt_field_type *); |
| 99 | static |
| 100 | void bt_field_type_enumeration_freeze(struct bt_field_type *); |
| 101 | static |
| 102 | void bt_field_type_structure_freeze(struct bt_field_type *); |
| 103 | static |
| 104 | void bt_field_type_variant_freeze(struct bt_field_type *); |
| 105 | static |
| 106 | void bt_field_type_array_freeze(struct bt_field_type *); |
| 107 | static |
| 108 | void bt_field_type_sequence_freeze(struct bt_field_type *); |
| 109 | |
| 110 | static |
| 111 | type_freeze_func const type_freeze_funcs[] = { |
| 112 | [BT_FIELD_TYPE_ID_INTEGER] = bt_field_type_integer_freeze, |
| 113 | [BT_FIELD_TYPE_ID_ENUM] = bt_field_type_enumeration_freeze, |
| 114 | [BT_FIELD_TYPE_ID_FLOAT] = generic_field_type_freeze, |
| 115 | [BT_FIELD_TYPE_ID_STRUCT] = bt_field_type_structure_freeze, |
| 116 | [BT_FIELD_TYPE_ID_VARIANT] = bt_field_type_variant_freeze, |
| 117 | [BT_FIELD_TYPE_ID_ARRAY] = bt_field_type_array_freeze, |
| 118 | [BT_FIELD_TYPE_ID_SEQUENCE] = bt_field_type_sequence_freeze, |
| 119 | [BT_FIELD_TYPE_ID_STRING] = generic_field_type_freeze, |
| 120 | }; |
| 121 | |
| 122 | static |
| 123 | int bt_field_type_integer_serialize(struct bt_field_type *, |
| 124 | struct metadata_context *); |
| 125 | static |
| 126 | int bt_field_type_enumeration_serialize(struct bt_field_type *, |
| 127 | struct metadata_context *); |
| 128 | static |
| 129 | int bt_field_type_floating_point_serialize( |
| 130 | struct bt_field_type *, struct metadata_context *); |
| 131 | static |
| 132 | int bt_field_type_structure_serialize(struct bt_field_type *, |
| 133 | struct metadata_context *); |
| 134 | static |
| 135 | int bt_field_type_variant_serialize(struct bt_field_type *, |
| 136 | struct metadata_context *); |
| 137 | static |
| 138 | int bt_field_type_array_serialize(struct bt_field_type *, |
| 139 | struct metadata_context *); |
| 140 | static |
| 141 | int bt_field_type_sequence_serialize(struct bt_field_type *, |
| 142 | struct metadata_context *); |
| 143 | static |
| 144 | int bt_field_type_string_serialize(struct bt_field_type *, |
| 145 | struct metadata_context *); |
| 146 | |
| 147 | static |
| 148 | type_serialize_func const type_serialize_funcs[] = { |
| 149 | [BT_FIELD_TYPE_ID_INTEGER] = bt_field_type_integer_serialize, |
| 150 | [BT_FIELD_TYPE_ID_ENUM] = |
| 151 | bt_field_type_enumeration_serialize, |
| 152 | [BT_FIELD_TYPE_ID_FLOAT] = |
| 153 | bt_field_type_floating_point_serialize, |
| 154 | [BT_FIELD_TYPE_ID_STRUCT] = |
| 155 | bt_field_type_structure_serialize, |
| 156 | [BT_FIELD_TYPE_ID_VARIANT] = bt_field_type_variant_serialize, |
| 157 | [BT_FIELD_TYPE_ID_ARRAY] = bt_field_type_array_serialize, |
| 158 | [BT_FIELD_TYPE_ID_SEQUENCE] = bt_field_type_sequence_serialize, |
| 159 | [BT_FIELD_TYPE_ID_STRING] = bt_field_type_string_serialize, |
| 160 | }; |
| 161 | |
| 162 | static |
| 163 | void bt_field_type_integer_set_byte_order(struct bt_field_type *, |
| 164 | enum bt_byte_order byte_order); |
| 165 | static |
| 166 | void bt_field_type_enumeration_set_byte_order(struct bt_field_type *, |
| 167 | enum bt_byte_order byte_order); |
| 168 | static |
| 169 | void bt_field_type_floating_point_set_byte_order( |
| 170 | struct bt_field_type *, enum bt_byte_order byte_order); |
| 171 | static |
| 172 | void bt_field_type_structure_set_byte_order(struct bt_field_type *, |
| 173 | enum bt_byte_order byte_order); |
| 174 | static |
| 175 | void bt_field_type_variant_set_byte_order(struct bt_field_type *, |
| 176 | enum bt_byte_order byte_order); |
| 177 | static |
| 178 | void bt_field_type_array_set_byte_order(struct bt_field_type *, |
| 179 | enum bt_byte_order byte_order); |
| 180 | static |
| 181 | void bt_field_type_sequence_set_byte_order(struct bt_field_type *, |
| 182 | enum bt_byte_order byte_order); |
| 183 | |
| 184 | static |
| 185 | void (* const set_byte_order_funcs[])(struct bt_field_type *, |
| 186 | enum bt_byte_order) = { |
| 187 | [BT_FIELD_TYPE_ID_INTEGER] = bt_field_type_integer_set_byte_order, |
| 188 | [BT_FIELD_TYPE_ID_ENUM] = |
| 189 | bt_field_type_enumeration_set_byte_order, |
| 190 | [BT_FIELD_TYPE_ID_FLOAT] = |
| 191 | bt_field_type_floating_point_set_byte_order, |
| 192 | [BT_FIELD_TYPE_ID_STRUCT] = |
| 193 | bt_field_type_structure_set_byte_order, |
| 194 | [BT_FIELD_TYPE_ID_VARIANT] = bt_field_type_variant_set_byte_order, |
| 195 | [BT_FIELD_TYPE_ID_ARRAY] = bt_field_type_array_set_byte_order, |
| 196 | [BT_FIELD_TYPE_ID_SEQUENCE] = bt_field_type_sequence_set_byte_order, |
| 197 | [BT_FIELD_TYPE_ID_STRING] = NULL, |
| 198 | }; |
| 199 | |
| 200 | static |
| 201 | struct bt_field_type *bt_field_type_integer_copy( |
| 202 | struct bt_field_type *); |
| 203 | static |
| 204 | struct bt_field_type *bt_field_type_enumeration_copy( |
| 205 | struct bt_field_type *); |
| 206 | static |
| 207 | struct bt_field_type *bt_field_type_floating_point_copy( |
| 208 | struct bt_field_type *); |
| 209 | static |
| 210 | struct bt_field_type *bt_field_type_structure_copy( |
| 211 | struct bt_field_type *); |
| 212 | static |
| 213 | struct bt_field_type *bt_field_type_variant_copy( |
| 214 | struct bt_field_type *); |
| 215 | static |
| 216 | struct bt_field_type *bt_field_type_array_copy( |
| 217 | struct bt_field_type *); |
| 218 | static |
| 219 | struct bt_field_type *bt_field_type_sequence_copy( |
| 220 | struct bt_field_type *); |
| 221 | static |
| 222 | struct bt_field_type *bt_field_type_string_copy( |
| 223 | struct bt_field_type *); |
| 224 | |
| 225 | static |
| 226 | struct bt_field_type *(* const type_copy_funcs[])( |
| 227 | struct bt_field_type *) = { |
| 228 | [BT_FIELD_TYPE_ID_INTEGER] = bt_field_type_integer_copy, |
| 229 | [BT_FIELD_TYPE_ID_ENUM] = bt_field_type_enumeration_copy, |
| 230 | [BT_FIELD_TYPE_ID_FLOAT] = bt_field_type_floating_point_copy, |
| 231 | [BT_FIELD_TYPE_ID_STRUCT] = bt_field_type_structure_copy, |
| 232 | [BT_FIELD_TYPE_ID_VARIANT] = bt_field_type_variant_copy, |
| 233 | [BT_FIELD_TYPE_ID_ARRAY] = bt_field_type_array_copy, |
| 234 | [BT_FIELD_TYPE_ID_SEQUENCE] = bt_field_type_sequence_copy, |
| 235 | [BT_FIELD_TYPE_ID_STRING] = bt_field_type_string_copy, |
| 236 | }; |
| 237 | |
| 238 | static |
| 239 | int bt_field_type_integer_compare(struct bt_field_type *, |
| 240 | struct bt_field_type *); |
| 241 | static |
| 242 | int bt_field_type_floating_point_compare(struct bt_field_type *, |
| 243 | struct bt_field_type *); |
| 244 | static |
| 245 | int bt_field_type_enumeration_compare(struct bt_field_type *, |
| 246 | struct bt_field_type *); |
| 247 | static |
| 248 | int bt_field_type_string_compare(struct bt_field_type *, |
| 249 | struct bt_field_type *); |
| 250 | static |
| 251 | int bt_field_type_structure_compare(struct bt_field_type *, |
| 252 | struct bt_field_type *); |
| 253 | static |
| 254 | int bt_field_type_variant_compare(struct bt_field_type *, |
| 255 | struct bt_field_type *); |
| 256 | static |
| 257 | int bt_field_type_array_compare(struct bt_field_type *, |
| 258 | struct bt_field_type *); |
| 259 | static |
| 260 | int bt_field_type_sequence_compare(struct bt_field_type *, |
| 261 | struct bt_field_type *); |
| 262 | |
| 263 | static |
| 264 | int (* const type_compare_funcs[])(struct bt_field_type *, |
| 265 | struct bt_field_type *) = { |
| 266 | [BT_FIELD_TYPE_ID_INTEGER] = bt_field_type_integer_compare, |
| 267 | [BT_FIELD_TYPE_ID_ENUM] = bt_field_type_enumeration_compare, |
| 268 | [BT_FIELD_TYPE_ID_FLOAT] = bt_field_type_floating_point_compare, |
| 269 | [BT_FIELD_TYPE_ID_STRUCT] = bt_field_type_structure_compare, |
| 270 | [BT_FIELD_TYPE_ID_VARIANT] = bt_field_type_variant_compare, |
| 271 | [BT_FIELD_TYPE_ID_ARRAY] = bt_field_type_array_compare, |
| 272 | [BT_FIELD_TYPE_ID_SEQUENCE] = bt_field_type_sequence_compare, |
| 273 | [BT_FIELD_TYPE_ID_STRING] = bt_field_type_string_compare, |
| 274 | }; |
| 275 | |
| 276 | static |
| 277 | int bt_field_type_integer_validate(struct bt_field_type *); |
| 278 | static |
| 279 | int bt_field_type_enumeration_validate(struct bt_field_type *); |
| 280 | static |
| 281 | int bt_field_type_structure_validate(struct bt_field_type *); |
| 282 | static |
| 283 | int bt_field_type_variant_validate(struct bt_field_type *); |
| 284 | static |
| 285 | int bt_field_type_array_validate(struct bt_field_type *); |
| 286 | static |
| 287 | int bt_field_type_sequence_validate(struct bt_field_type *); |
| 288 | |
| 289 | static |
| 290 | int (* const type_validate_funcs[])(struct bt_field_type *) = { |
| 291 | [BT_FIELD_TYPE_ID_INTEGER] = bt_field_type_integer_validate, |
| 292 | [BT_FIELD_TYPE_ID_FLOAT] = NULL, |
| 293 | [BT_FIELD_TYPE_ID_STRING] = NULL, |
| 294 | [BT_FIELD_TYPE_ID_ENUM] = bt_field_type_enumeration_validate, |
| 295 | [BT_FIELD_TYPE_ID_STRUCT] = bt_field_type_structure_validate, |
| 296 | [BT_FIELD_TYPE_ID_VARIANT] = bt_field_type_variant_validate, |
| 297 | [BT_FIELD_TYPE_ID_ARRAY] = bt_field_type_array_validate, |
| 298 | [BT_FIELD_TYPE_ID_SEQUENCE] = bt_field_type_sequence_validate, |
| 299 | }; |
| 300 | |
| 301 | static |
| 302 | void destroy_enumeration_mapping(struct enumeration_mapping *mapping) |
| 303 | { |
| 304 | g_free(mapping); |
| 305 | } |
| 306 | |
| 307 | static |
| 308 | void destroy_structure_field(struct structure_field *field) |
| 309 | { |
| 310 | if (!field) { |
| 311 | return; |
| 312 | } |
| 313 | |
| 314 | BT_LOGD("Destroying structure/variant field type's field object: " |
| 315 | "addr=%p, field-ft-addr=%p, field-name=\"%s\"", |
| 316 | field, field->type, g_quark_to_string(field->name)); |
| 317 | BT_LOGD_STR("Putting field type."); |
| 318 | bt_put(field->type); |
| 319 | g_free(field); |
| 320 | } |
| 321 | |
| 322 | static |
| 323 | void check_ranges_overlap(gpointer element, gpointer query) |
| 324 | { |
| 325 | struct enumeration_mapping *mapping = element; |
| 326 | struct range_overlap_query *overlap_query = query; |
| 327 | |
| 328 | if (mapping->range_start._signed <= overlap_query->range_end._signed |
| 329 | && overlap_query->range_start._signed <= |
| 330 | mapping->range_end._signed) { |
| 331 | overlap_query->overlaps = 1; |
| 332 | overlap_query->mapping_name = mapping->string; |
| 333 | } |
| 334 | |
| 335 | overlap_query->overlaps |= |
| 336 | mapping->string == overlap_query->mapping_name; |
| 337 | |
| 338 | if (overlap_query->overlaps) { |
| 339 | BT_LOGV("Overlapping enumeration field type mappings: " |
| 340 | "mapping-name=\"%s\", " |
| 341 | "mapping-a-range-start=%" PRId64 ", " |
| 342 | "mapping-a-range-end=%" PRId64 ", " |
| 343 | "mapping-b-range-start=%" PRId64 ", " |
| 344 | "mapping-b-range-end=%" PRId64, |
| 345 | g_quark_to_string(mapping->string), |
| 346 | mapping->range_start._signed, |
| 347 | mapping->range_end._signed, |
| 348 | overlap_query->range_start._signed, |
| 349 | overlap_query->range_end._signed); |
| 350 | } |
| 351 | } |
| 352 | |
| 353 | static |
| 354 | void check_ranges_overlap_unsigned(gpointer element, gpointer query) |
| 355 | { |
| 356 | struct enumeration_mapping *mapping = element; |
| 357 | struct range_overlap_query *overlap_query = query; |
| 358 | |
| 359 | if (mapping->range_start._unsigned <= overlap_query->range_end._unsigned |
| 360 | && overlap_query->range_start._unsigned <= |
| 361 | mapping->range_end._unsigned) { |
| 362 | overlap_query->overlaps = 1; |
| 363 | overlap_query->mapping_name = mapping->string; |
| 364 | } |
| 365 | |
| 366 | overlap_query->overlaps |= |
| 367 | mapping->string == overlap_query->mapping_name; |
| 368 | |
| 369 | if (overlap_query->overlaps) { |
| 370 | BT_LOGW("Overlapping enumeration field type mappings: " |
| 371 | "mapping-name=\"%s\", " |
| 372 | "mapping-a-range-start=%" PRIu64 ", " |
| 373 | "mapping-a-range-end=%" PRIu64 ", " |
| 374 | "mapping-b-range-start=%" PRIu64 ", " |
| 375 | "mapping-b-range-end=%" PRIu64, |
| 376 | g_quark_to_string(mapping->string), |
| 377 | mapping->range_start._unsigned, |
| 378 | mapping->range_end._unsigned, |
| 379 | overlap_query->range_start._unsigned, |
| 380 | overlap_query->range_end._unsigned); |
| 381 | } |
| 382 | } |
| 383 | |
| 384 | static |
| 385 | gint compare_enumeration_mappings_signed(struct enumeration_mapping **a, |
| 386 | struct enumeration_mapping **b) |
| 387 | { |
| 388 | return ((*a)->range_start._signed < (*b)->range_start._signed) ? -1 : 1; |
| 389 | } |
| 390 | |
| 391 | static |
| 392 | gint compare_enumeration_mappings_unsigned(struct enumeration_mapping **a, |
| 393 | struct enumeration_mapping **b) |
| 394 | { |
| 395 | return ((*a)->range_start._unsigned < (*b)->range_start._unsigned) ? -1 : 1; |
| 396 | } |
| 397 | |
| 398 | static |
| 399 | void bt_field_type_init(struct bt_field_type *type, bt_bool init_bo) |
| 400 | { |
| 401 | BT_ASSERT(type && (type->id > BT_FIELD_TYPE_ID_UNKNOWN) && |
| 402 | (type->id < BT_FIELD_TYPE_ID_NR)); |
| 403 | |
| 404 | bt_object_init(type, bt_field_type_destroy); |
| 405 | type->freeze = type_freeze_funcs[type->id]; |
| 406 | type->serialize = type_serialize_funcs[type->id]; |
| 407 | |
| 408 | if (init_bo) { |
| 409 | int ret; |
| 410 | const enum bt_byte_order bo = BT_BYTE_ORDER_NATIVE; |
| 411 | |
| 412 | BT_LOGD("Setting initial field type's byte order: bo=%s", |
| 413 | bt_byte_order_string(bo)); |
| 414 | ret = bt_field_type_set_byte_order(type, bo); |
| 415 | BT_ASSERT(ret == 0); |
| 416 | } |
| 417 | |
| 418 | type->alignment = 1; |
| 419 | } |
| 420 | |
| 421 | static |
| 422 | int add_structure_field(GPtrArray *fields, |
| 423 | GHashTable *field_name_to_index, |
| 424 | struct bt_field_type *field_type, |
| 425 | const char *field_name) |
| 426 | { |
| 427 | int ret = 0; |
| 428 | GQuark name_quark = g_quark_from_string(field_name); |
| 429 | struct structure_field *field; |
| 430 | |
| 431 | /* Make sure structure does not contain a field of the same name */ |
| 432 | if (g_hash_table_lookup_extended(field_name_to_index, |
| 433 | GUINT_TO_POINTER(name_quark), NULL, NULL)) { |
| 434 | BT_LOGW("Structure or variant field type already contains a field type with this name: " |
| 435 | "field-name=\"%s\"", field_name); |
| 436 | ret = -1; |
| 437 | goto end; |
| 438 | } |
| 439 | |
| 440 | field = g_new0(struct structure_field, 1); |
| 441 | if (!field) { |
| 442 | BT_LOGE_STR("Failed to allocate one structure/variant field type field."); |
| 443 | ret = -1; |
| 444 | goto end; |
| 445 | } |
| 446 | |
| 447 | bt_get(field_type); |
| 448 | field->name = name_quark; |
| 449 | field->type = field_type; |
| 450 | g_hash_table_insert(field_name_to_index, |
| 451 | GUINT_TO_POINTER(name_quark), |
| 452 | GUINT_TO_POINTER(fields->len)); |
| 453 | g_ptr_array_add(fields, field); |
| 454 | BT_LOGV("Added structure/variant field type field: field-ft-addr=%p, " |
| 455 | "field-name=\"%s\"", field_type, field_name); |
| 456 | end: |
| 457 | return ret; |
| 458 | } |
| 459 | |
| 460 | static |
| 461 | void bt_field_type_destroy(struct bt_object *obj) |
| 462 | { |
| 463 | struct bt_field_type *type; |
| 464 | enum bt_field_type_id type_id; |
| 465 | |
| 466 | type = container_of(obj, struct bt_field_type, base); |
| 467 | type_id = type->id; |
| 468 | BT_ASSERT(type_id > BT_FIELD_TYPE_ID_UNKNOWN && |
| 469 | type_id < BT_FIELD_TYPE_ID_NR); |
| 470 | type_destroy_funcs[type_id](type); |
| 471 | } |
| 472 | |
| 473 | static |
| 474 | int bt_field_type_integer_validate(struct bt_field_type *type) |
| 475 | { |
| 476 | int ret = 0; |
| 477 | |
| 478 | struct bt_field_type_integer *integer = |
| 479 | container_of(type, struct bt_field_type_integer, |
| 480 | parent); |
| 481 | |
| 482 | if (integer->mapped_clock && integer->is_signed) { |
| 483 | BT_LOGW("Invalid integer field type: cannot be signed and have a mapped clock class: " |
| 484 | "ft-addr=%p, clock-class-addr=%p, clock-class-name=\"%s\"", |
| 485 | type, integer->mapped_clock, |
| 486 | bt_clock_class_get_name(integer->mapped_clock)); |
| 487 | ret = -1; |
| 488 | goto end; |
| 489 | } |
| 490 | |
| 491 | end: |
| 492 | return ret; |
| 493 | } |
| 494 | |
| 495 | static |
| 496 | struct enumeration_mapping *get_enumeration_mapping( |
| 497 | struct bt_field_type *type, uint64_t index) |
| 498 | { |
| 499 | struct enumeration_mapping *mapping = NULL; |
| 500 | struct bt_field_type_enumeration *enumeration; |
| 501 | |
| 502 | enumeration = container_of(type, struct bt_field_type_enumeration, |
| 503 | parent); |
| 504 | if (index >= enumeration->entries->len) { |
| 505 | BT_LOGW("Invalid parameter: index is out of bounds: " |
| 506 | "addr=%p, index=%" PRIu64 ", count=%u", |
| 507 | type, index, enumeration->entries->len); |
| 508 | goto end; |
| 509 | } |
| 510 | |
| 511 | mapping = g_ptr_array_index(enumeration->entries, index); |
| 512 | end: |
| 513 | return mapping; |
| 514 | } |
| 515 | |
| 516 | /* |
| 517 | * Note: This algorithm is O(n^2) vs number of enumeration mappings. |
| 518 | * Only used when freezing an enumeration. |
| 519 | */ |
| 520 | static |
| 521 | void set_enumeration_range_overlap( |
| 522 | struct bt_field_type *type) |
| 523 | { |
| 524 | int64_t i, j, len; |
| 525 | struct bt_field_type *container_type; |
| 526 | struct bt_field_type_enumeration *enumeration_type; |
| 527 | int is_signed; |
| 528 | |
| 529 | BT_LOGV("Setting enumeration field type's overlap flag: addr=%p", |
| 530 | type); |
| 531 | enumeration_type = container_of(type, |
| 532 | struct bt_field_type_enumeration, parent); |
| 533 | |
| 534 | len = enumeration_type->entries->len; |
| 535 | container_type = enumeration_type->container; |
| 536 | is_signed = bt_field_type_integer_is_signed(container_type); |
| 537 | |
| 538 | for (i = 0; i < len; i++) { |
| 539 | for (j = i + 1; j < len; j++) { |
| 540 | struct enumeration_mapping *mapping[2]; |
| 541 | |
| 542 | mapping[0] = get_enumeration_mapping(type, i); |
| 543 | mapping[1] = get_enumeration_mapping(type, j); |
| 544 | if (is_signed) { |
| 545 | if (mapping[0]->range_start._signed |
| 546 | <= mapping[1]->range_end._signed |
| 547 | && mapping[0]->range_end._signed |
| 548 | >= mapping[1]->range_start._signed) { |
| 549 | enumeration_type->has_overlapping_ranges = BT_TRUE; |
| 550 | goto end; |
| 551 | } |
| 552 | } else { |
| 553 | if (mapping[0]->range_start._unsigned |
| 554 | <= mapping[1]->range_end._unsigned |
| 555 | && mapping[0]->range_end._unsigned |
| 556 | >= mapping[1]->range_start._unsigned) { |
| 557 | enumeration_type->has_overlapping_ranges = BT_TRUE; |
| 558 | goto end; |
| 559 | } |
| 560 | } |
| 561 | } |
| 562 | } |
| 563 | |
| 564 | end: |
| 565 | if (enumeration_type->has_overlapping_ranges) { |
| 566 | BT_LOGV_STR("Enumeration field type has overlapping ranges."); |
| 567 | } else { |
| 568 | BT_LOGV_STR("Enumeration field type has no overlapping ranges."); |
| 569 | } |
| 570 | } |
| 571 | |
| 572 | static |
| 573 | int bt_field_type_enumeration_validate(struct bt_field_type *type) |
| 574 | { |
| 575 | int ret = 0; |
| 576 | |
| 577 | struct bt_field_type_enumeration *enumeration = |
| 578 | container_of(type, struct bt_field_type_enumeration, |
| 579 | parent); |
| 580 | struct bt_field_type *container_type = |
| 581 | bt_field_type_enumeration_get_container_type(type); |
| 582 | |
| 583 | BT_ASSERT(container_type); |
| 584 | ret = bt_field_type_validate(container_type); |
| 585 | if (ret) { |
| 586 | BT_LOGW("Invalid enumeration field type: container type is invalid: " |
| 587 | "enum-ft-addr=%p, int-ft-addr=%p", |
| 588 | type, container_type); |
| 589 | goto end; |
| 590 | } |
| 591 | |
| 592 | /* Ensure enum has entries */ |
| 593 | if (enumeration->entries->len == 0) { |
| 594 | BT_LOGW("Invalid enumeration field type: no entries: " |
| 595 | "addr=%p", type); |
| 596 | ret = -1; |
| 597 | goto end; |
| 598 | } |
| 599 | |
| 600 | end: |
| 601 | BT_PUT(container_type); |
| 602 | return ret; |
| 603 | } |
| 604 | |
| 605 | static |
| 606 | int bt_field_type_sequence_validate(struct bt_field_type *type) |
| 607 | { |
| 608 | int ret = 0; |
| 609 | struct bt_field_type *element_type = NULL; |
| 610 | struct bt_field_type_sequence *sequence = |
| 611 | container_of(type, struct bt_field_type_sequence, |
| 612 | parent); |
| 613 | |
| 614 | /* Length field name should be set at this point */ |
| 615 | if (sequence->length_field_name->len == 0) { |
| 616 | BT_LOGW("Invalid sequence field type: no length field name: " |
| 617 | "addr=%p", type); |
| 618 | ret = -1; |
| 619 | goto end; |
| 620 | } |
| 621 | |
| 622 | element_type = bt_field_type_sequence_get_element_type(type); |
| 623 | BT_ASSERT(element_type); |
| 624 | ret = bt_field_type_validate(element_type); |
| 625 | if (ret) { |
| 626 | BT_LOGW("Invalid sequence field type: invalid element field type: " |
| 627 | "seq-ft-addr=%p, element-ft-add=%p", |
| 628 | type, element_type); |
| 629 | } |
| 630 | |
| 631 | end: |
| 632 | BT_PUT(element_type); |
| 633 | |
| 634 | return ret; |
| 635 | } |
| 636 | |
| 637 | static |
| 638 | int bt_field_type_array_validate(struct bt_field_type *type) |
| 639 | { |
| 640 | int ret = 0; |
| 641 | struct bt_field_type *element_type = NULL; |
| 642 | |
| 643 | element_type = bt_field_type_array_get_element_type(type); |
| 644 | BT_ASSERT(element_type); |
| 645 | ret = bt_field_type_validate(element_type); |
| 646 | if (ret) { |
| 647 | BT_LOGW("Invalid array field type: invalid element field type: " |
| 648 | "array-ft-addr=%p, element-ft-add=%p", |
| 649 | type, element_type); |
| 650 | } |
| 651 | |
| 652 | BT_PUT(element_type); |
| 653 | return ret; |
| 654 | } |
| 655 | |
| 656 | static |
| 657 | int bt_field_type_structure_validate(struct bt_field_type *type) |
| 658 | { |
| 659 | int ret = 0; |
| 660 | struct bt_field_type *child_type = NULL; |
| 661 | int64_t field_count = bt_field_type_structure_get_field_count(type); |
| 662 | int64_t i; |
| 663 | |
| 664 | BT_ASSERT(field_count >= 0); |
| 665 | |
| 666 | for (i = 0; i < field_count; ++i) { |
| 667 | const char *field_name; |
| 668 | |
| 669 | ret = bt_field_type_structure_get_field_by_index(type, |
| 670 | &field_name, &child_type, i); |
| 671 | BT_ASSERT(ret == 0); |
| 672 | ret = bt_field_type_validate(child_type); |
| 673 | if (ret) { |
| 674 | BT_LOGW("Invalid structure field type: " |
| 675 | "a contained field type is invalid: " |
| 676 | "struct-ft-addr=%p, field-ft-addr=%p, " |
| 677 | "field-name=\"%s\", field-index=%" PRId64, |
| 678 | type, child_type, field_name, i); |
| 679 | goto end; |
| 680 | } |
| 681 | |
| 682 | BT_PUT(child_type); |
| 683 | } |
| 684 | |
| 685 | end: |
| 686 | BT_PUT(child_type); |
| 687 | |
| 688 | return ret; |
| 689 | } |
| 690 | |
| 691 | static |
| 692 | bt_bool bt_field_type_enumeration_has_overlapping_ranges( |
| 693 | struct bt_field_type_enumeration *enumeration_type) |
| 694 | { |
| 695 | if (!enumeration_type->parent.frozen) { |
| 696 | set_enumeration_range_overlap(&enumeration_type->parent); |
| 697 | } |
| 698 | return enumeration_type->has_overlapping_ranges; |
| 699 | } |
| 700 | |
| 701 | static |
| 702 | int bt_field_type_variant_validate(struct bt_field_type *type) |
| 703 | { |
| 704 | int ret = 0; |
| 705 | int64_t field_count; |
| 706 | struct bt_field_type *child_type = NULL; |
| 707 | struct bt_field_type_variant *variant = |
| 708 | container_of(type, struct bt_field_type_variant, |
| 709 | parent); |
| 710 | int64_t i; |
| 711 | |
| 712 | if (variant->tag_name->len == 0) { |
| 713 | BT_LOGW("Invalid variant field type: no tag field name: " |
| 714 | "addr=%p", type); |
| 715 | ret = -1; |
| 716 | goto end; |
| 717 | } |
| 718 | |
| 719 | if (!variant->tag) { |
| 720 | BT_LOGW("Invalid variant field type: no tag field type: " |
| 721 | "addr=%p, tag-field-name=\"%s\"", type, |
| 722 | variant->tag_name->str); |
| 723 | ret = -1; |
| 724 | goto end; |
| 725 | } |
| 726 | |
| 727 | if (bt_field_type_enumeration_has_overlapping_ranges( |
| 728 | variant->tag)) { |
| 729 | BT_LOGW("Invalid variant field type: enumeration tag field type has overlapping ranges: " |
| 730 | "variant-ft-addr=%p, tag-field-name=\"%s\", " |
| 731 | "enum-ft-addr=%p", type, variant->tag_name->str, |
| 732 | variant->tag); |
| 733 | ret = -1; |
| 734 | goto end; |
| 735 | } |
| 736 | |
| 737 | /* |
| 738 | * It is valid to have a variant field type which does not have |
| 739 | * the fields corresponding to each label in the associated |
| 740 | * enumeration. |
| 741 | * |
| 742 | * It is also valid to have variant field type fields which |
| 743 | * cannot be selected because the variant field type tag has no |
| 744 | * mapping named as such. This scenario, while not ideal, cannot |
| 745 | * cause any error. |
| 746 | * |
| 747 | * If a non-existing field happens to be selected by an |
| 748 | * enumeration while reading a variant field, an error will be |
| 749 | * generated at that point (while reading the stream). |
| 750 | */ |
| 751 | field_count = bt_field_type_variant_get_field_count(type); |
| 752 | if (field_count < 0) { |
| 753 | BT_LOGW("Invalid variant field type: no fields: " |
| 754 | "addr=%p, tag-field-name=\"%s\"", |
| 755 | type, variant->tag_name->str); |
| 756 | ret = -1; |
| 757 | goto end; |
| 758 | } |
| 759 | |
| 760 | for (i = 0; i < field_count; ++i) { |
| 761 | const char *field_name; |
| 762 | |
| 763 | ret = bt_field_type_variant_get_field_by_index(type, |
| 764 | &field_name, &child_type, i); |
| 765 | BT_ASSERT(ret == 0); |
| 766 | ret = bt_field_type_validate(child_type); |
| 767 | if (ret) { |
| 768 | BT_LOGW("Invalid variant field type: " |
| 769 | "a contained field type is invalid: " |
| 770 | "variant-ft-addr=%p, tag-field-name=\"%s\", " |
| 771 | "field-ft-addr=%p, field-name=\"%s\", " |
| 772 | "field-index=%" PRId64, |
| 773 | type, variant->tag_name->str, child_type, |
| 774 | field_name, i); |
| 775 | goto end; |
| 776 | } |
| 777 | |
| 778 | BT_PUT(child_type); |
| 779 | } |
| 780 | |
| 781 | end: |
| 782 | BT_PUT(child_type); |
| 783 | |
| 784 | return ret; |
| 785 | } |
| 786 | |
| 787 | /* |
| 788 | * This function validates a given field type without considering |
| 789 | * where this field type is located. It only validates the properties |
| 790 | * of the given field type and the properties of its children if |
| 791 | * applicable. |
| 792 | */ |
| 793 | BT_HIDDEN |
| 794 | int bt_field_type_validate(struct bt_field_type *type) |
| 795 | { |
| 796 | int ret = 0; |
| 797 | enum bt_field_type_id id = bt_field_type_get_type_id(type); |
| 798 | |
| 799 | BT_ASSERT(type); |
| 800 | |
| 801 | if (type->valid) { |
| 802 | /* Already marked as valid */ |
| 803 | goto end; |
| 804 | } |
| 805 | |
| 806 | if (type_validate_funcs[id]) { |
| 807 | ret = type_validate_funcs[id](type); |
| 808 | } |
| 809 | |
| 810 | if (!ret && type->frozen) { |
| 811 | /* Field type is valid */ |
| 812 | BT_LOGV("Marking field type as valid: addr=%p", type); |
| 813 | type->valid = 1; |
| 814 | } |
| 815 | |
| 816 | end: |
| 817 | return ret; |
| 818 | } |
| 819 | |
| 820 | struct bt_field_type *bt_field_type_integer_create(unsigned int size) |
| 821 | { |
| 822 | struct bt_field_type_integer *integer = |
| 823 | g_new0(struct bt_field_type_integer, 1); |
| 824 | |
| 825 | BT_LOGD("Creating integer field type object: size=%u", size); |
| 826 | |
| 827 | if (!integer) { |
| 828 | BT_LOGE_STR("Failed to allocate one integer field type."); |
| 829 | return NULL; |
| 830 | } |
| 831 | |
| 832 | if (size == 0 || size > 64) { |
| 833 | BT_LOGW("Invalid parameter: size must be between 1 and 64: " |
| 834 | "size=%u", size); |
| 835 | return NULL; |
| 836 | } |
| 837 | |
| 838 | integer->parent.id = BT_FIELD_TYPE_ID_INTEGER; |
| 839 | integer->size = size; |
| 840 | integer->base = BT_INTEGER_BASE_DECIMAL; |
| 841 | integer->encoding = BT_STRING_ENCODING_NONE; |
| 842 | bt_field_type_init(&integer->parent, TRUE); |
| 843 | BT_LOGD("Created integer field type object: addr=%p, size=%u", |
| 844 | &integer->parent, size); |
| 845 | return &integer->parent; |
| 846 | } |
| 847 | |
| 848 | int bt_field_type_integer_get_size(struct bt_field_type *type) |
| 849 | { |
| 850 | int ret = 0; |
| 851 | struct bt_field_type_integer *integer; |
| 852 | |
| 853 | if (!type) { |
| 854 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 855 | ret = -1; |
| 856 | goto end; |
| 857 | } |
| 858 | |
| 859 | if (type->id != BT_FIELD_TYPE_ID_INTEGER) { |
| 860 | BT_LOGW("Invalid parameter: field type is not an integer field type: " |
| 861 | "addr=%p, ft-id=%s", type, |
| 862 | bt_field_type_id_string(type->id)); |
| 863 | ret = -1; |
| 864 | goto end; |
| 865 | } |
| 866 | |
| 867 | integer = container_of(type, struct bt_field_type_integer, parent); |
| 868 | ret = (int) integer->size; |
| 869 | end: |
| 870 | return ret; |
| 871 | } |
| 872 | |
| 873 | int bt_ctf_field_type_integer_get_signed(struct bt_field_type *type) |
| 874 | { |
| 875 | int ret = 0; |
| 876 | struct bt_field_type_integer *integer; |
| 877 | |
| 878 | if (!type) { |
| 879 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 880 | ret = -1; |
| 881 | goto end; |
| 882 | } |
| 883 | |
| 884 | if (type->id != BT_FIELD_TYPE_ID_INTEGER) { |
| 885 | BT_LOGW("Invalid parameter: field type is not an integer field type: " |
| 886 | "addr=%p, ft-id=%s", type, |
| 887 | bt_field_type_id_string(type->id)); |
| 888 | ret = -1; |
| 889 | goto end; |
| 890 | } |
| 891 | |
| 892 | integer = container_of(type, struct bt_field_type_integer, parent); |
| 893 | ret = integer->is_signed; |
| 894 | end: |
| 895 | return ret; |
| 896 | } |
| 897 | |
| 898 | bt_bool bt_field_type_integer_is_signed( |
| 899 | struct bt_field_type *int_field_type) |
| 900 | { |
| 901 | return bt_ctf_field_type_integer_get_signed(int_field_type) ? |
| 902 | BT_TRUE : BT_FALSE; |
| 903 | } |
| 904 | |
| 905 | int bt_field_type_integer_set_is_signed(struct bt_field_type *type, |
| 906 | bt_bool is_signed) |
| 907 | { |
| 908 | int ret = 0; |
| 909 | struct bt_field_type_integer *integer; |
| 910 | |
| 911 | if (!type) { |
| 912 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 913 | ret = -1; |
| 914 | goto end; |
| 915 | } |
| 916 | |
| 917 | if (type->frozen) { |
| 918 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 919 | type); |
| 920 | ret = -1; |
| 921 | goto end; |
| 922 | } |
| 923 | |
| 924 | if (type->id != BT_FIELD_TYPE_ID_INTEGER) { |
| 925 | BT_LOGW("Invalid parameter: field type is not an integer field type: " |
| 926 | "addr=%p, ft-id=%s", type, |
| 927 | bt_field_type_id_string(type->id)); |
| 928 | ret = -1; |
| 929 | goto end; |
| 930 | } |
| 931 | |
| 932 | integer = container_of(type, struct bt_field_type_integer, parent); |
| 933 | integer->is_signed = !!is_signed; |
| 934 | BT_LOGV("Set integer field type's signedness: addr=%p, is-signed=%d", |
| 935 | type, is_signed); |
| 936 | end: |
| 937 | return ret; |
| 938 | } |
| 939 | |
| 940 | int bt_field_type_integer_set_size(struct bt_field_type *type, |
| 941 | unsigned int size) |
| 942 | { |
| 943 | int ret = 0; |
| 944 | struct bt_field_type_integer *integer; |
| 945 | |
| 946 | if (!type) { |
| 947 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 948 | ret = -1; |
| 949 | goto end; |
| 950 | } |
| 951 | |
| 952 | if (type->frozen) { |
| 953 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 954 | type); |
| 955 | ret = -1; |
| 956 | goto end; |
| 957 | } |
| 958 | |
| 959 | if (type->id != BT_FIELD_TYPE_ID_INTEGER) { |
| 960 | BT_LOGW("Invalid parameter: field type is not an integer field type: " |
| 961 | "addr=%p, ft-id=%s", type, |
| 962 | bt_field_type_id_string(type->id)); |
| 963 | ret = -1; |
| 964 | goto end; |
| 965 | } |
| 966 | |
| 967 | if (size == 0 || size > 64) { |
| 968 | BT_LOGW("Invalid parameter: size must be between 1 and 64: " |
| 969 | "addr=%p, size=%u", type, size); |
| 970 | ret = -1; |
| 971 | goto end; |
| 972 | } |
| 973 | |
| 974 | integer = container_of(type, struct bt_field_type_integer, parent); |
| 975 | integer->size = size; |
| 976 | BT_LOGV("Set integer field type's size: addr=%p, size=%u", |
| 977 | type, size); |
| 978 | end: |
| 979 | return ret; |
| 980 | } |
| 981 | |
| 982 | enum bt_integer_base bt_field_type_integer_get_base( |
| 983 | struct bt_field_type *type) |
| 984 | { |
| 985 | enum bt_integer_base ret = BT_INTEGER_BASE_UNKNOWN; |
| 986 | struct bt_field_type_integer *integer; |
| 987 | |
| 988 | if (!type) { |
| 989 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 990 | goto end; |
| 991 | } |
| 992 | |
| 993 | if (type->id != BT_FIELD_TYPE_ID_INTEGER) { |
| 994 | BT_LOGW("Invalid parameter: field type is not an integer field type: " |
| 995 | "addr=%p, ft-id=%s", type, |
| 996 | bt_field_type_id_string(type->id)); |
| 997 | goto end; |
| 998 | } |
| 999 | |
| 1000 | integer = container_of(type, struct bt_field_type_integer, parent); |
| 1001 | ret = integer->base; |
| 1002 | end: |
| 1003 | return ret; |
| 1004 | } |
| 1005 | |
| 1006 | int bt_field_type_integer_set_base(struct bt_field_type *type, |
| 1007 | enum bt_integer_base base) |
| 1008 | { |
| 1009 | int ret = 0; |
| 1010 | |
| 1011 | if (!type) { |
| 1012 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1013 | ret = -1; |
| 1014 | goto end; |
| 1015 | } |
| 1016 | |
| 1017 | if (type->frozen) { |
| 1018 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 1019 | type); |
| 1020 | ret = -1; |
| 1021 | goto end; |
| 1022 | } |
| 1023 | |
| 1024 | if (type->id != BT_FIELD_TYPE_ID_INTEGER) { |
| 1025 | BT_LOGW("Invalid parameter: field type is not an integer field type: " |
| 1026 | "addr=%p, ft-id=%s", type, |
| 1027 | bt_field_type_id_string(type->id)); |
| 1028 | ret = -1; |
| 1029 | goto end; |
| 1030 | } |
| 1031 | |
| 1032 | switch (base) { |
| 1033 | case BT_INTEGER_BASE_UNSPECIFIED: |
| 1034 | case BT_INTEGER_BASE_BINARY: |
| 1035 | case BT_INTEGER_BASE_OCTAL: |
| 1036 | case BT_INTEGER_BASE_DECIMAL: |
| 1037 | case BT_INTEGER_BASE_HEXADECIMAL: |
| 1038 | { |
| 1039 | struct bt_field_type_integer *integer = container_of(type, |
| 1040 | struct bt_field_type_integer, parent); |
| 1041 | integer->base = base; |
| 1042 | break; |
| 1043 | } |
| 1044 | default: |
| 1045 | BT_LOGW("Invalid parameter: unknown integer field type base: " |
| 1046 | "addr=%p, base=%d", type, base); |
| 1047 | ret = -1; |
| 1048 | } |
| 1049 | |
| 1050 | BT_LOGV("Set integer field type's base: addr=%p, base=%s", |
| 1051 | type, bt_integer_base_string(base)); |
| 1052 | |
| 1053 | end: |
| 1054 | return ret; |
| 1055 | } |
| 1056 | |
| 1057 | enum bt_string_encoding bt_field_type_integer_get_encoding( |
| 1058 | struct bt_field_type *type) |
| 1059 | { |
| 1060 | enum bt_string_encoding ret = BT_STRING_ENCODING_UNKNOWN; |
| 1061 | struct bt_field_type_integer *integer; |
| 1062 | |
| 1063 | if (!type) { |
| 1064 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1065 | goto end; |
| 1066 | } |
| 1067 | |
| 1068 | if (type->id != BT_FIELD_TYPE_ID_INTEGER) { |
| 1069 | BT_LOGW("Invalid parameter: field type is not an integer field type: " |
| 1070 | "addr=%p, ft-id=%s", type, |
| 1071 | bt_field_type_id_string(type->id)); |
| 1072 | goto end; |
| 1073 | } |
| 1074 | |
| 1075 | integer = container_of(type, struct bt_field_type_integer, parent); |
| 1076 | ret = integer->encoding; |
| 1077 | end: |
| 1078 | return ret; |
| 1079 | } |
| 1080 | |
| 1081 | int bt_field_type_integer_set_encoding(struct bt_field_type *type, |
| 1082 | enum bt_string_encoding encoding) |
| 1083 | { |
| 1084 | int ret = 0; |
| 1085 | struct bt_field_type_integer *integer; |
| 1086 | |
| 1087 | if (!type) { |
| 1088 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1089 | ret = -1; |
| 1090 | goto end; |
| 1091 | } |
| 1092 | |
| 1093 | if (type->frozen) { |
| 1094 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 1095 | type); |
| 1096 | ret = -1; |
| 1097 | goto end; |
| 1098 | } |
| 1099 | |
| 1100 | if (type->id != BT_FIELD_TYPE_ID_INTEGER) { |
| 1101 | BT_LOGW("Invalid parameter: field type is not an integer field type: " |
| 1102 | "addr=%p, ft-id=%s", type, |
| 1103 | bt_field_type_id_string(type->id)); |
| 1104 | ret = -1; |
| 1105 | goto end; |
| 1106 | } |
| 1107 | |
| 1108 | if (encoding != BT_STRING_ENCODING_UTF8 && |
| 1109 | encoding != BT_STRING_ENCODING_ASCII && |
| 1110 | encoding != BT_STRING_ENCODING_NONE) { |
| 1111 | BT_LOGW("Invalid parameter: unknown string encoding: " |
| 1112 | "addr=%p, encoding=%d", type, encoding); |
| 1113 | ret = -1; |
| 1114 | goto end; |
| 1115 | } |
| 1116 | |
| 1117 | integer = container_of(type, struct bt_field_type_integer, parent); |
| 1118 | integer->encoding = encoding; |
| 1119 | BT_LOGV("Set integer field type's encoding: addr=%p, encoding=%s", |
| 1120 | type, bt_string_encoding_string(encoding)); |
| 1121 | end: |
| 1122 | return ret; |
| 1123 | } |
| 1124 | |
| 1125 | struct bt_clock_class *bt_field_type_integer_get_mapped_clock_class( |
| 1126 | struct bt_field_type *type) |
| 1127 | { |
| 1128 | struct bt_field_type_integer *integer; |
| 1129 | struct bt_clock_class *clock_class = NULL; |
| 1130 | |
| 1131 | if (!type) { |
| 1132 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1133 | goto end; |
| 1134 | } |
| 1135 | |
| 1136 | integer = container_of(type, struct bt_field_type_integer, parent); |
| 1137 | clock_class = integer->mapped_clock; |
| 1138 | bt_get(clock_class); |
| 1139 | end: |
| 1140 | return clock_class; |
| 1141 | } |
| 1142 | |
| 1143 | BT_HIDDEN |
| 1144 | int bt_field_type_integer_set_mapped_clock_class_no_check( |
| 1145 | struct bt_field_type *type, |
| 1146 | struct bt_clock_class *clock_class) |
| 1147 | { |
| 1148 | struct bt_field_type_integer *integer; |
| 1149 | int ret = 0; |
| 1150 | |
| 1151 | if (!type) { |
| 1152 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1153 | ret = -1; |
| 1154 | goto end; |
| 1155 | } |
| 1156 | |
| 1157 | if (!clock_class) { |
| 1158 | BT_LOGW_STR("Invalid parameter: clock class is NULL."); |
| 1159 | ret = -1; |
| 1160 | goto end; |
| 1161 | } |
| 1162 | |
| 1163 | if (type->id != BT_FIELD_TYPE_ID_INTEGER) { |
| 1164 | BT_LOGW("Invalid parameter: field type is not an integer field type: " |
| 1165 | "addr=%p, ft-id=%s", type, |
| 1166 | bt_field_type_id_string(type->id)); |
| 1167 | goto end; |
| 1168 | } |
| 1169 | |
| 1170 | if (!bt_clock_class_is_valid(clock_class)) { |
| 1171 | BT_LOGW("Invalid parameter: clock class is invalid: ft-addr=%p" |
| 1172 | "clock-class-addr=%p, clock-class-name=\"%s\"", |
| 1173 | type, clock_class, |
| 1174 | bt_clock_class_get_name(clock_class)); |
| 1175 | ret = -1; |
| 1176 | goto end; |
| 1177 | } |
| 1178 | |
| 1179 | integer = container_of(type, struct bt_field_type_integer, parent); |
| 1180 | bt_put(integer->mapped_clock); |
| 1181 | integer->mapped_clock = bt_get(clock_class); |
| 1182 | BT_LOGV("Set integer field type's mapped clock class: ft-addr=%p, " |
| 1183 | "clock-class-addr=%p, clock-class-name=\"%s\"", |
| 1184 | type, clock_class, bt_clock_class_get_name(clock_class)); |
| 1185 | end: |
| 1186 | return ret; |
| 1187 | } |
| 1188 | |
| 1189 | int bt_field_type_integer_set_mapped_clock_class( |
| 1190 | struct bt_field_type *type, |
| 1191 | struct bt_clock_class *clock_class) |
| 1192 | { |
| 1193 | int ret = 0; |
| 1194 | |
| 1195 | if (!type) { |
| 1196 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1197 | ret = -1; |
| 1198 | goto end; |
| 1199 | } |
| 1200 | |
| 1201 | if (type->frozen) { |
| 1202 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 1203 | type); |
| 1204 | ret = -1; |
| 1205 | goto end; |
| 1206 | } |
| 1207 | |
| 1208 | ret = bt_field_type_integer_set_mapped_clock_class_no_check( |
| 1209 | type, clock_class); |
| 1210 | |
| 1211 | end: |
| 1212 | return ret; |
| 1213 | } |
| 1214 | |
| 1215 | static |
| 1216 | void bt_field_type_enum_iter_destroy(struct bt_object *obj) |
| 1217 | { |
| 1218 | struct bt_field_type_enumeration_mapping_iterator *iter = |
| 1219 | container_of(obj, |
| 1220 | struct bt_field_type_enumeration_mapping_iterator, |
| 1221 | base); |
| 1222 | |
| 1223 | BT_LOGD("Destroying enumeration field type mapping iterator: addr=%p", |
| 1224 | obj); |
| 1225 | BT_LOGD_STR("Putting parent enumeration field type."); |
| 1226 | bt_put(&iter->enumeration_type->parent); |
| 1227 | g_free(iter); |
| 1228 | } |
| 1229 | |
| 1230 | static |
| 1231 | struct bt_field_type_enumeration_mapping_iterator * |
| 1232 | bt_field_type_enumeration_find_mappings_type( |
| 1233 | struct bt_field_type *type, |
| 1234 | enum bt_field_type_enumeration_mapping_iterator_type iterator_type) |
| 1235 | { |
| 1236 | struct bt_field_type_enumeration *enumeration_type; |
| 1237 | struct bt_field_type_enumeration_mapping_iterator *iter = NULL; |
| 1238 | |
| 1239 | if (!type) { |
| 1240 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1241 | goto end; |
| 1242 | } |
| 1243 | |
| 1244 | if (type->id != BT_FIELD_TYPE_ID_ENUM) { |
| 1245 | BT_LOGW("Invalid parameter: field type is not an enumeration field type: " |
| 1246 | "addr=%p, ft-id=%s", type, |
| 1247 | bt_field_type_id_string(type->id)); |
| 1248 | goto end; |
| 1249 | } |
| 1250 | |
| 1251 | enumeration_type = container_of(type, |
| 1252 | struct bt_field_type_enumeration, parent); |
| 1253 | iter = g_new0(struct bt_field_type_enumeration_mapping_iterator, 1); |
| 1254 | if (!iter) { |
| 1255 | BT_LOGE_STR("Failed to allocate one enumeration field type mapping."); |
| 1256 | goto end; |
| 1257 | } |
| 1258 | |
| 1259 | bt_object_init(&iter->base, bt_field_type_enum_iter_destroy); |
| 1260 | bt_get(type); |
| 1261 | iter->enumeration_type = enumeration_type; |
| 1262 | iter->index = -1; |
| 1263 | iter->type = iterator_type; |
| 1264 | end: |
| 1265 | return iter; |
| 1266 | } |
| 1267 | |
| 1268 | struct bt_field_type_enumeration_mapping_iterator * |
| 1269 | bt_field_type_enumeration_find_mappings_by_name( |
| 1270 | struct bt_field_type *type, const char *name) |
| 1271 | { |
| 1272 | struct bt_field_type_enumeration_mapping_iterator *iter; |
| 1273 | |
| 1274 | iter = bt_field_type_enumeration_find_mappings_type( |
| 1275 | type, ITERATOR_BY_NAME); |
| 1276 | if (!iter) { |
| 1277 | BT_LOGW("Cannot create enumeration field type mapping iterator: " |
| 1278 | "ft-addr=%p, mapping-name=\"%s\"", type, name); |
| 1279 | goto error; |
| 1280 | } |
| 1281 | |
| 1282 | iter->u.name_quark = g_quark_try_string(name); |
| 1283 | if (!iter->u.name_quark) { |
| 1284 | /* |
| 1285 | * No results are possible, set the iterator's position at the |
| 1286 | * end. |
| 1287 | */ |
| 1288 | iter->index = iter->enumeration_type->entries->len; |
| 1289 | } |
| 1290 | return iter; |
| 1291 | error: |
| 1292 | bt_put(iter); |
| 1293 | return NULL; |
| 1294 | } |
| 1295 | |
| 1296 | int bt_field_type_enumeration_mapping_iterator_next( |
| 1297 | struct bt_field_type_enumeration_mapping_iterator *iter) |
| 1298 | { |
| 1299 | struct bt_field_type_enumeration *enumeration; |
| 1300 | struct bt_field_type *type; |
| 1301 | int i, ret = 0, len; |
| 1302 | |
| 1303 | if (!iter) { |
| 1304 | BT_LOGW_STR("Invalid parameter: enumeration field type mapping iterator is NULL."); |
| 1305 | ret = -1; |
| 1306 | goto end; |
| 1307 | } |
| 1308 | |
| 1309 | enumeration = iter->enumeration_type; |
| 1310 | type = &enumeration->parent; |
| 1311 | len = enumeration->entries->len; |
| 1312 | for (i = iter->index + 1; i < len; i++) { |
| 1313 | struct enumeration_mapping *mapping = |
| 1314 | get_enumeration_mapping(type, i); |
| 1315 | |
| 1316 | switch (iter->type) { |
| 1317 | case ITERATOR_BY_NAME: |
| 1318 | if (mapping->string == iter->u.name_quark) { |
| 1319 | iter->index = i; |
| 1320 | goto end; |
| 1321 | } |
| 1322 | break; |
| 1323 | case ITERATOR_BY_SIGNED_VALUE: |
| 1324 | { |
| 1325 | int64_t value = iter->u.signed_value; |
| 1326 | |
| 1327 | if (value >= mapping->range_start._signed && |
| 1328 | value <= mapping->range_end._signed) { |
| 1329 | iter->index = i; |
| 1330 | goto end; |
| 1331 | } |
| 1332 | break; |
| 1333 | } |
| 1334 | case ITERATOR_BY_UNSIGNED_VALUE: |
| 1335 | { |
| 1336 | uint64_t value = iter->u.unsigned_value; |
| 1337 | |
| 1338 | if (value >= mapping->range_start._unsigned && |
| 1339 | value <= mapping->range_end._unsigned) { |
| 1340 | iter->index = i; |
| 1341 | goto end; |
| 1342 | } |
| 1343 | break; |
| 1344 | } |
| 1345 | default: |
| 1346 | BT_LOGF("Invalid enumeration field type mapping iterator type: " |
| 1347 | "type=%d", iter->type); |
| 1348 | abort(); |
| 1349 | } |
| 1350 | } |
| 1351 | |
| 1352 | ret = -1; |
| 1353 | end: |
| 1354 | return ret; |
| 1355 | } |
| 1356 | |
| 1357 | struct bt_field_type_enumeration_mapping_iterator * |
| 1358 | bt_field_type_enumeration_find_mappings_by_signed_value( |
| 1359 | struct bt_field_type *type, int64_t value) |
| 1360 | { |
| 1361 | struct bt_field_type_enumeration_mapping_iterator *iter; |
| 1362 | |
| 1363 | iter = bt_field_type_enumeration_find_mappings_type( |
| 1364 | type, ITERATOR_BY_SIGNED_VALUE); |
| 1365 | if (!iter) { |
| 1366 | BT_LOGW("Cannot create enumeration field type mapping iterator: " |
| 1367 | "ft-addr=%p, value=%" PRId64, type, value); |
| 1368 | goto error; |
| 1369 | } |
| 1370 | |
| 1371 | if (bt_ctf_field_type_integer_get_signed( |
| 1372 | iter->enumeration_type->container) != 1) { |
| 1373 | BT_LOGW("Invalid parameter: enumeration field type is unsigned: " |
| 1374 | "enum-ft-addr=%p, int-ft-addr=%p", |
| 1375 | type, iter->enumeration_type->container); |
| 1376 | goto error; |
| 1377 | } |
| 1378 | |
| 1379 | iter->u.signed_value = value; |
| 1380 | return iter; |
| 1381 | error: |
| 1382 | bt_put(iter); |
| 1383 | return NULL; |
| 1384 | } |
| 1385 | |
| 1386 | struct bt_field_type_enumeration_mapping_iterator * |
| 1387 | bt_field_type_enumeration_find_mappings_by_unsigned_value( |
| 1388 | struct bt_field_type *type, uint64_t value) |
| 1389 | { |
| 1390 | struct bt_field_type_enumeration_mapping_iterator *iter; |
| 1391 | |
| 1392 | iter = bt_field_type_enumeration_find_mappings_type( |
| 1393 | type, ITERATOR_BY_UNSIGNED_VALUE); |
| 1394 | if (!iter) { |
| 1395 | BT_LOGW("Cannot create enumeration field type mapping iterator: " |
| 1396 | "ft-addr=%p, value=%" PRIu64, type, value); |
| 1397 | goto error; |
| 1398 | } |
| 1399 | |
| 1400 | if (bt_ctf_field_type_integer_get_signed( |
| 1401 | iter->enumeration_type->container) != 0) { |
| 1402 | BT_LOGW("Invalid parameter: enumeration field type is signed: " |
| 1403 | "enum-ft-addr=%p, int-ft-addr=%p", |
| 1404 | type, iter->enumeration_type->container); |
| 1405 | goto error; |
| 1406 | } |
| 1407 | iter->u.unsigned_value = value; |
| 1408 | return iter; |
| 1409 | error: |
| 1410 | bt_put(iter); |
| 1411 | return NULL; |
| 1412 | } |
| 1413 | |
| 1414 | int bt_field_type_enumeration_mapping_iterator_get_signed( |
| 1415 | struct bt_field_type_enumeration_mapping_iterator *iter, |
| 1416 | const char **mapping_name, int64_t *range_begin, |
| 1417 | int64_t *range_end) |
| 1418 | { |
| 1419 | int ret = 0; |
| 1420 | |
| 1421 | if (!iter) { |
| 1422 | BT_LOGW_STR("Invalid parameter: enumeration field type mapping iterator is NULL."); |
| 1423 | ret = -1; |
| 1424 | goto end; |
| 1425 | } |
| 1426 | |
| 1427 | if (iter->index == -1) { |
| 1428 | BT_LOGW_STR("Invalid enumeration field type mapping iterator access: position=-1"); |
| 1429 | ret = -1; |
| 1430 | goto end; |
| 1431 | } |
| 1432 | |
| 1433 | ret = bt_field_type_enumeration_get_mapping_signed( |
| 1434 | &iter->enumeration_type->parent, iter->index, |
| 1435 | mapping_name, range_begin, range_end); |
| 1436 | end: |
| 1437 | return ret; |
| 1438 | } |
| 1439 | |
| 1440 | int bt_field_type_enumeration_mapping_iterator_get_unsigned( |
| 1441 | struct bt_field_type_enumeration_mapping_iterator *iter, |
| 1442 | const char **mapping_name, uint64_t *range_begin, |
| 1443 | uint64_t *range_end) |
| 1444 | { |
| 1445 | int ret = 0; |
| 1446 | |
| 1447 | if (!iter) { |
| 1448 | BT_LOGW_STR("Invalid parameter: enumeration field type mapping iterator is NULL."); |
| 1449 | ret = -1; |
| 1450 | goto end; |
| 1451 | } |
| 1452 | |
| 1453 | if (iter->index == -1) { |
| 1454 | BT_LOGW_STR("Invalid enumeration field type mapping iterator access: position=-1"); |
| 1455 | ret = -1; |
| 1456 | goto end; |
| 1457 | } |
| 1458 | |
| 1459 | ret = bt_field_type_enumeration_get_mapping_unsigned( |
| 1460 | &iter->enumeration_type->parent, iter->index, |
| 1461 | mapping_name, range_begin, range_end); |
| 1462 | end: |
| 1463 | return ret; |
| 1464 | } |
| 1465 | |
| 1466 | int bt_field_type_enumeration_get_mapping_signed( |
| 1467 | struct bt_field_type *enum_field_type, |
| 1468 | uint64_t index, const char **mapping_name, int64_t *range_begin, |
| 1469 | int64_t *range_end) |
| 1470 | { |
| 1471 | int ret = 0; |
| 1472 | struct enumeration_mapping *mapping; |
| 1473 | |
| 1474 | if (!enum_field_type) { |
| 1475 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1476 | ret = -1; |
| 1477 | goto end; |
| 1478 | } |
| 1479 | |
| 1480 | mapping = get_enumeration_mapping(enum_field_type, index); |
| 1481 | if (!mapping) { |
| 1482 | /* get_enumeration_mapping() reports any error */ |
| 1483 | ret = -1; |
| 1484 | goto end; |
| 1485 | } |
| 1486 | |
| 1487 | if (mapping_name) { |
| 1488 | *mapping_name = g_quark_to_string(mapping->string); |
| 1489 | BT_ASSERT(*mapping_name); |
| 1490 | } |
| 1491 | |
| 1492 | if (range_begin) { |
| 1493 | *range_begin = mapping->range_start._signed; |
| 1494 | } |
| 1495 | |
| 1496 | if (range_end) { |
| 1497 | *range_end = mapping->range_end._signed; |
| 1498 | } |
| 1499 | end: |
| 1500 | return ret; |
| 1501 | } |
| 1502 | |
| 1503 | int bt_field_type_enumeration_get_mapping_unsigned( |
| 1504 | struct bt_field_type *enum_field_type, |
| 1505 | uint64_t index, |
| 1506 | const char **mapping_name, uint64_t *range_begin, |
| 1507 | uint64_t *range_end) |
| 1508 | { |
| 1509 | int ret = 0; |
| 1510 | struct enumeration_mapping *mapping; |
| 1511 | |
| 1512 | if (!enum_field_type) { |
| 1513 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1514 | ret = -1; |
| 1515 | goto end; |
| 1516 | } |
| 1517 | |
| 1518 | mapping = get_enumeration_mapping(enum_field_type, index); |
| 1519 | if (!mapping) { |
| 1520 | /* get_enumeration_mapping() reports any error */ |
| 1521 | ret = -1; |
| 1522 | goto end; |
| 1523 | } |
| 1524 | |
| 1525 | if (mapping_name) { |
| 1526 | *mapping_name = g_quark_to_string(mapping->string); |
| 1527 | BT_ASSERT(*mapping_name); |
| 1528 | } |
| 1529 | |
| 1530 | if (range_begin) { |
| 1531 | *range_begin = mapping->range_start._unsigned; |
| 1532 | } |
| 1533 | |
| 1534 | if (range_end) { |
| 1535 | *range_end = mapping->range_end._unsigned; |
| 1536 | } |
| 1537 | end: |
| 1538 | return ret; |
| 1539 | } |
| 1540 | |
| 1541 | struct bt_field_type *bt_field_type_enumeration_create( |
| 1542 | struct bt_field_type *integer_container_type) |
| 1543 | { |
| 1544 | struct bt_field_type_enumeration *enumeration = NULL; |
| 1545 | |
| 1546 | BT_LOGD("Creating enumeration field type object: int-ft-addr=%p", |
| 1547 | integer_container_type); |
| 1548 | |
| 1549 | if (!integer_container_type) { |
| 1550 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1551 | goto error; |
| 1552 | } |
| 1553 | |
| 1554 | if (integer_container_type->id != BT_FIELD_TYPE_ID_INTEGER) { |
| 1555 | BT_LOGW("Invalid parameter: container field type is not an integer field type: " |
| 1556 | "container-ft-addr=%p, container-ft-id=%s", |
| 1557 | integer_container_type, |
| 1558 | bt_field_type_id_string(integer_container_type->id)); |
| 1559 | goto error; |
| 1560 | } |
| 1561 | |
| 1562 | enumeration = g_new0(struct bt_field_type_enumeration, 1); |
| 1563 | if (!enumeration) { |
| 1564 | BT_LOGE_STR("Failed to allocate one enumeration field type."); |
| 1565 | goto error; |
| 1566 | } |
| 1567 | |
| 1568 | enumeration->parent.id = BT_FIELD_TYPE_ID_ENUM; |
| 1569 | bt_get(integer_container_type); |
| 1570 | enumeration->container = integer_container_type; |
| 1571 | enumeration->entries = g_ptr_array_new_with_free_func( |
| 1572 | (GDestroyNotify)destroy_enumeration_mapping); |
| 1573 | bt_field_type_init(&enumeration->parent, FALSE); |
| 1574 | BT_LOGD("Created enumeration field type object: addr=%p, " |
| 1575 | "int-ft-addr=%p, int-ft-size=%u", |
| 1576 | &enumeration->parent, integer_container_type, |
| 1577 | bt_field_type_integer_get_size(integer_container_type)); |
| 1578 | return &enumeration->parent; |
| 1579 | error: |
| 1580 | g_free(enumeration); |
| 1581 | return NULL; |
| 1582 | } |
| 1583 | |
| 1584 | struct bt_field_type *bt_field_type_enumeration_get_container_type( |
| 1585 | struct bt_field_type *type) |
| 1586 | { |
| 1587 | struct bt_field_type *container_type = NULL; |
| 1588 | struct bt_field_type_enumeration *enumeration_type; |
| 1589 | |
| 1590 | if (!type) { |
| 1591 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1592 | goto end; |
| 1593 | } |
| 1594 | |
| 1595 | if (type->id != BT_FIELD_TYPE_ID_ENUM) { |
| 1596 | BT_LOGW("Invalid parameter: field type is not an enumeration field type: " |
| 1597 | "addr=%p, ft-id=%s", type, |
| 1598 | bt_field_type_id_string(type->id)); |
| 1599 | goto end; |
| 1600 | } |
| 1601 | |
| 1602 | enumeration_type = container_of(type, |
| 1603 | struct bt_field_type_enumeration, parent); |
| 1604 | container_type = enumeration_type->container; |
| 1605 | bt_get(container_type); |
| 1606 | end: |
| 1607 | return container_type; |
| 1608 | } |
| 1609 | |
| 1610 | int bt_field_type_enumeration_add_mapping_signed( |
| 1611 | struct bt_field_type *type, const char *string, |
| 1612 | int64_t range_start, int64_t range_end) |
| 1613 | { |
| 1614 | int ret = 0; |
| 1615 | GQuark mapping_name; |
| 1616 | struct enumeration_mapping *mapping; |
| 1617 | struct bt_field_type_enumeration *enumeration; |
| 1618 | char *escaped_string; |
| 1619 | |
| 1620 | if (!type) { |
| 1621 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1622 | ret = -1; |
| 1623 | goto end; |
| 1624 | } |
| 1625 | |
| 1626 | if (!string) { |
| 1627 | BT_LOGW_STR("Invalid parameter: string is NULL."); |
| 1628 | ret = -1; |
| 1629 | goto end; |
| 1630 | } |
| 1631 | |
| 1632 | if (type->frozen) { |
| 1633 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 1634 | type); |
| 1635 | ret = -1; |
| 1636 | goto end; |
| 1637 | } |
| 1638 | |
| 1639 | if (type->id != BT_FIELD_TYPE_ID_ENUM) { |
| 1640 | BT_LOGW("Invalid parameter: field type is not an enumeration field type: " |
| 1641 | "addr=%p, ft-id=%s", type, |
| 1642 | bt_field_type_id_string(type->id)); |
| 1643 | ret = -1; |
| 1644 | goto end; |
| 1645 | } |
| 1646 | |
| 1647 | if (range_end < range_start) { |
| 1648 | BT_LOGW("Invalid parameter: range's end is lesser than range's start: " |
| 1649 | "addr=%p, range-start=%" PRId64 ", range-end=%" PRId64, |
| 1650 | type, range_start, range_end); |
| 1651 | ret = -1; |
| 1652 | goto end; |
| 1653 | } |
| 1654 | |
| 1655 | if (strlen(string) == 0) { |
| 1656 | BT_LOGW("Invalid parameter: mapping name is an empty string: " |
| 1657 | "enum-ft-addr=%p, mapping-name-addr=%p", type, |
| 1658 | string); |
| 1659 | ret = -1; |
| 1660 | goto end; |
| 1661 | } |
| 1662 | |
| 1663 | escaped_string = g_strescape(string, NULL); |
| 1664 | if (!escaped_string) { |
| 1665 | BT_LOGE("Cannot escape mapping name: enum-ft-addr=%p, " |
| 1666 | "mapping-name-addr=%p, mapping-name=\"%s\"", |
| 1667 | type, string, string); |
| 1668 | ret = -1; |
| 1669 | goto end; |
| 1670 | } |
| 1671 | |
| 1672 | mapping = g_new(struct enumeration_mapping, 1); |
| 1673 | if (!mapping) { |
| 1674 | BT_LOGE_STR("Failed to allocate one enumeration mapping."); |
| 1675 | ret = -1; |
| 1676 | goto error_free; |
| 1677 | } |
| 1678 | mapping_name = g_quark_from_string(escaped_string); |
| 1679 | *mapping = (struct enumeration_mapping) { |
| 1680 | .range_start._signed = range_start, |
| 1681 | .range_end._signed = range_end, |
| 1682 | .string = mapping_name, |
| 1683 | }; |
| 1684 | enumeration = container_of(type, struct bt_field_type_enumeration, |
| 1685 | parent); |
| 1686 | g_ptr_array_add(enumeration->entries, mapping); |
| 1687 | g_ptr_array_sort(enumeration->entries, |
| 1688 | (GCompareFunc)compare_enumeration_mappings_signed); |
| 1689 | BT_LOGV("Added mapping to signed enumeration field type: addr=%p, " |
| 1690 | "name=\"%s\", range-start=%" PRId64 ", " |
| 1691 | "range-end=%" PRId64, |
| 1692 | type, string, range_start, range_end); |
| 1693 | error_free: |
| 1694 | free(escaped_string); |
| 1695 | end: |
| 1696 | return ret; |
| 1697 | } |
| 1698 | |
| 1699 | int bt_field_type_enumeration_add_mapping_unsigned( |
| 1700 | struct bt_field_type *type, const char *string, |
| 1701 | uint64_t range_start, uint64_t range_end) |
| 1702 | { |
| 1703 | int ret = 0; |
| 1704 | GQuark mapping_name; |
| 1705 | struct enumeration_mapping *mapping; |
| 1706 | struct bt_field_type_enumeration *enumeration; |
| 1707 | char *escaped_string; |
| 1708 | |
| 1709 | if (!type) { |
| 1710 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1711 | ret = -1; |
| 1712 | goto end; |
| 1713 | } |
| 1714 | |
| 1715 | if (!string) { |
| 1716 | BT_LOGW_STR("Invalid parameter: string is NULL."); |
| 1717 | ret = -1; |
| 1718 | goto end; |
| 1719 | } |
| 1720 | |
| 1721 | if (type->frozen) { |
| 1722 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 1723 | type); |
| 1724 | ret = -1; |
| 1725 | goto end; |
| 1726 | } |
| 1727 | |
| 1728 | if (type->id != BT_FIELD_TYPE_ID_ENUM) { |
| 1729 | BT_LOGW("Invalid parameter: field type is not an enumeration field type: " |
| 1730 | "addr=%p, ft-id=%s", type, |
| 1731 | bt_field_type_id_string(type->id)); |
| 1732 | ret = -1; |
| 1733 | goto end; |
| 1734 | } |
| 1735 | |
| 1736 | if (range_end < range_start) { |
| 1737 | BT_LOGW("Invalid parameter: range's end is lesser than range's start: " |
| 1738 | "addr=%p, range-start=%" PRIu64 ", range-end=%" PRIu64, |
| 1739 | type, range_start, range_end); |
| 1740 | ret = -1; |
| 1741 | goto end; |
| 1742 | } |
| 1743 | |
| 1744 | if (strlen(string) == 0) { |
| 1745 | BT_LOGW("Invalid parameter: mapping name is an empty string: " |
| 1746 | "enum-ft-addr=%p, mapping-name-addr=%p", type, |
| 1747 | string); |
| 1748 | ret = -1; |
| 1749 | goto end; |
| 1750 | } |
| 1751 | |
| 1752 | escaped_string = g_strescape(string, NULL); |
| 1753 | if (!escaped_string) { |
| 1754 | BT_LOGE("Cannot escape mapping name: enum-ft-addr=%p, " |
| 1755 | "mapping-name-addr=%p, mapping-name=\"%s\"", |
| 1756 | type, string, string); |
| 1757 | ret = -1; |
| 1758 | goto end; |
| 1759 | } |
| 1760 | |
| 1761 | mapping = g_new(struct enumeration_mapping, 1); |
| 1762 | if (!mapping) { |
| 1763 | BT_LOGE_STR("Failed to allocate one enumeration mapping."); |
| 1764 | ret = -1; |
| 1765 | goto error_free; |
| 1766 | } |
| 1767 | mapping_name = g_quark_from_string(escaped_string); |
| 1768 | *mapping = (struct enumeration_mapping) { |
| 1769 | .range_start._unsigned = range_start, |
| 1770 | .range_end._unsigned = range_end, |
| 1771 | .string = mapping_name, |
| 1772 | }; |
| 1773 | enumeration = container_of(type, struct bt_field_type_enumeration, |
| 1774 | parent); |
| 1775 | g_ptr_array_add(enumeration->entries, mapping); |
| 1776 | g_ptr_array_sort(enumeration->entries, |
| 1777 | (GCompareFunc)compare_enumeration_mappings_unsigned); |
| 1778 | BT_LOGV("Added mapping to unsigned enumeration field type: addr=%p, " |
| 1779 | "name=\"%s\", range-start=%" PRIu64 ", " |
| 1780 | "range-end=%" PRIu64, |
| 1781 | type, string, range_start, range_end); |
| 1782 | error_free: |
| 1783 | free(escaped_string); |
| 1784 | end: |
| 1785 | return ret; |
| 1786 | } |
| 1787 | |
| 1788 | int64_t bt_field_type_enumeration_get_mapping_count( |
| 1789 | struct bt_field_type *type) |
| 1790 | { |
| 1791 | int64_t ret = 0; |
| 1792 | struct bt_field_type_enumeration *enumeration; |
| 1793 | |
| 1794 | if (!type) { |
| 1795 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1796 | ret = (int64_t) -1; |
| 1797 | goto end; |
| 1798 | } |
| 1799 | |
| 1800 | if (type->id != BT_FIELD_TYPE_ID_ENUM) { |
| 1801 | BT_LOGW("Invalid parameter: field type is not an enumeration field type: " |
| 1802 | "addr=%p, ft-id=%s", type, |
| 1803 | bt_field_type_id_string(type->id)); |
| 1804 | ret = (int64_t) -1; |
| 1805 | goto end; |
| 1806 | } |
| 1807 | |
| 1808 | enumeration = container_of(type, struct bt_field_type_enumeration, |
| 1809 | parent); |
| 1810 | ret = (int64_t) enumeration->entries->len; |
| 1811 | end: |
| 1812 | return ret; |
| 1813 | } |
| 1814 | |
| 1815 | struct bt_field_type *bt_field_type_floating_point_create(void) |
| 1816 | { |
| 1817 | struct bt_field_type_floating_point *floating_point = |
| 1818 | g_new0(struct bt_field_type_floating_point, 1); |
| 1819 | |
| 1820 | BT_LOGD_STR("Creating floating point number field type object."); |
| 1821 | |
| 1822 | if (!floating_point) { |
| 1823 | BT_LOGE_STR("Failed to allocate one floating point number field type."); |
| 1824 | goto end; |
| 1825 | } |
| 1826 | |
| 1827 | floating_point->parent.id = BT_FIELD_TYPE_ID_FLOAT; |
| 1828 | floating_point->exp_dig = sizeof(float) * CHAR_BIT - FLT_MANT_DIG; |
| 1829 | floating_point->mant_dig = FLT_MANT_DIG; |
| 1830 | bt_field_type_init(&floating_point->parent, TRUE); |
| 1831 | BT_LOGD("Created floating point number field type object: addr=%p, " |
| 1832 | "exp-size=%u, mant-size=%u", &floating_point->parent, |
| 1833 | floating_point->exp_dig, floating_point->mant_dig); |
| 1834 | end: |
| 1835 | return floating_point ? &floating_point->parent : NULL; |
| 1836 | } |
| 1837 | |
| 1838 | int bt_field_type_floating_point_get_exponent_digits( |
| 1839 | struct bt_field_type *type) |
| 1840 | { |
| 1841 | int ret = 0; |
| 1842 | struct bt_field_type_floating_point *floating_point; |
| 1843 | |
| 1844 | if (!type) { |
| 1845 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1846 | ret = -1; |
| 1847 | goto end; |
| 1848 | } |
| 1849 | |
| 1850 | if (type->id != BT_FIELD_TYPE_ID_FLOAT) { |
| 1851 | BT_LOGW("Invalid parameter: field type is not a floating point number field type: " |
| 1852 | "addr=%p, ft-id=%s", type, |
| 1853 | bt_field_type_id_string(type->id)); |
| 1854 | ret = -1; |
| 1855 | goto end; |
| 1856 | } |
| 1857 | |
| 1858 | floating_point = container_of(type, |
| 1859 | struct bt_field_type_floating_point, parent); |
| 1860 | ret = (int) floating_point->exp_dig; |
| 1861 | end: |
| 1862 | return ret; |
| 1863 | } |
| 1864 | |
| 1865 | int bt_field_type_floating_point_set_exponent_digits( |
| 1866 | struct bt_field_type *type, |
| 1867 | unsigned int exponent_digits) |
| 1868 | { |
| 1869 | int ret = 0; |
| 1870 | struct bt_field_type_floating_point *floating_point; |
| 1871 | |
| 1872 | if (!type) { |
| 1873 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1874 | ret = -1; |
| 1875 | goto end; |
| 1876 | } |
| 1877 | |
| 1878 | if (type->frozen) { |
| 1879 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 1880 | type); |
| 1881 | ret = -1; |
| 1882 | goto end; |
| 1883 | } |
| 1884 | |
| 1885 | if (type->id != BT_FIELD_TYPE_ID_FLOAT) { |
| 1886 | BT_LOGW("Invalid parameter: field type is not a floating point number field type: " |
| 1887 | "addr=%p, ft-id=%s", type, |
| 1888 | bt_field_type_id_string(type->id)); |
| 1889 | ret = -1; |
| 1890 | goto end; |
| 1891 | } |
| 1892 | |
| 1893 | floating_point = container_of(type, |
| 1894 | struct bt_field_type_floating_point, parent); |
| 1895 | if ((exponent_digits != sizeof(float) * CHAR_BIT - FLT_MANT_DIG) && |
| 1896 | (exponent_digits != sizeof(double) * CHAR_BIT - DBL_MANT_DIG) && |
| 1897 | (exponent_digits != |
| 1898 | sizeof(long double) * CHAR_BIT - LDBL_MANT_DIG)) { |
| 1899 | BT_LOGW("Invalid parameter: invalid exponent size: " |
| 1900 | "addr=%p, exp-size=%u", type, exponent_digits); |
| 1901 | ret = -1; |
| 1902 | goto end; |
| 1903 | } |
| 1904 | |
| 1905 | floating_point->exp_dig = exponent_digits; |
| 1906 | BT_LOGV("Set floating point number field type's exponent size: addr=%p, " |
| 1907 | "exp-size=%u", type, exponent_digits); |
| 1908 | end: |
| 1909 | return ret; |
| 1910 | } |
| 1911 | |
| 1912 | int bt_field_type_floating_point_get_mantissa_digits( |
| 1913 | struct bt_field_type *type) |
| 1914 | { |
| 1915 | int ret = 0; |
| 1916 | struct bt_field_type_floating_point *floating_point; |
| 1917 | |
| 1918 | if (!type) { |
| 1919 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1920 | ret = -1; |
| 1921 | goto end; |
| 1922 | } |
| 1923 | |
| 1924 | if (type->id != BT_FIELD_TYPE_ID_FLOAT) { |
| 1925 | BT_LOGW("Invalid parameter: field type is not a floating point number field type: " |
| 1926 | "addr=%p, ft-id=%s", type, |
| 1927 | bt_field_type_id_string(type->id)); |
| 1928 | ret = -1; |
| 1929 | goto end; |
| 1930 | } |
| 1931 | |
| 1932 | floating_point = container_of(type, |
| 1933 | struct bt_field_type_floating_point, parent); |
| 1934 | ret = (int) floating_point->mant_dig; |
| 1935 | end: |
| 1936 | return ret; |
| 1937 | } |
| 1938 | |
| 1939 | int bt_field_type_floating_point_set_mantissa_digits( |
| 1940 | struct bt_field_type *type, |
| 1941 | unsigned int mantissa_digits) |
| 1942 | { |
| 1943 | int ret = 0; |
| 1944 | struct bt_field_type_floating_point *floating_point; |
| 1945 | |
| 1946 | if (!type) { |
| 1947 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 1948 | ret = -1; |
| 1949 | goto end; |
| 1950 | } |
| 1951 | |
| 1952 | if (type->frozen) { |
| 1953 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 1954 | type); |
| 1955 | ret = -1; |
| 1956 | goto end; |
| 1957 | } |
| 1958 | |
| 1959 | if (type->id != BT_FIELD_TYPE_ID_FLOAT) { |
| 1960 | BT_LOGW("Invalid parameter: field type is not a floating point number field type: " |
| 1961 | "addr=%p, ft-id=%s", type, |
| 1962 | bt_field_type_id_string(type->id)); |
| 1963 | ret = -1; |
| 1964 | goto end; |
| 1965 | } |
| 1966 | |
| 1967 | floating_point = container_of(type, |
| 1968 | struct bt_field_type_floating_point, parent); |
| 1969 | |
| 1970 | if ((mantissa_digits != FLT_MANT_DIG) && |
| 1971 | (mantissa_digits != DBL_MANT_DIG) && |
| 1972 | (mantissa_digits != LDBL_MANT_DIG)) { |
| 1973 | BT_LOGW("Invalid parameter: invalid mantissa size: " |
| 1974 | "addr=%p, mant-size=%u", type, mantissa_digits); |
| 1975 | ret = -1; |
| 1976 | goto end; |
| 1977 | } |
| 1978 | |
| 1979 | floating_point->mant_dig = mantissa_digits; |
| 1980 | BT_LOGV("Set floating point number field type's mantissa size: addr=%p, " |
| 1981 | "mant-size=%u", type, mantissa_digits); |
| 1982 | end: |
| 1983 | return ret; |
| 1984 | } |
| 1985 | |
| 1986 | struct bt_field_type *bt_field_type_structure_create(void) |
| 1987 | { |
| 1988 | struct bt_field_type_structure *structure = |
| 1989 | g_new0(struct bt_field_type_structure, 1); |
| 1990 | |
| 1991 | BT_LOGD_STR("Creating structure field type object."); |
| 1992 | |
| 1993 | if (!structure) { |
| 1994 | BT_LOGE_STR("Failed to allocate one structure field type."); |
| 1995 | goto error; |
| 1996 | } |
| 1997 | |
| 1998 | structure->parent.id = BT_FIELD_TYPE_ID_STRUCT; |
| 1999 | structure->fields = g_ptr_array_new_with_free_func( |
| 2000 | (GDestroyNotify)destroy_structure_field); |
| 2001 | structure->field_name_to_index = g_hash_table_new(NULL, NULL); |
| 2002 | bt_field_type_init(&structure->parent, TRUE); |
| 2003 | BT_LOGD("Created structure field type object: addr=%p", |
| 2004 | &structure->parent); |
| 2005 | return &structure->parent; |
| 2006 | error: |
| 2007 | return NULL; |
| 2008 | } |
| 2009 | |
| 2010 | BT_HIDDEN |
| 2011 | int bt_field_type_structure_replace_field(struct bt_field_type *type, |
| 2012 | const char *field_name, struct bt_field_type *field_type) |
| 2013 | { |
| 2014 | int ret = 0; |
| 2015 | struct bt_field_type_structure *structure; |
| 2016 | GQuark name_quark; |
| 2017 | uint64_t i; |
| 2018 | |
| 2019 | BT_ASSERT(type); |
| 2020 | BT_ASSERT(field_name); |
| 2021 | BT_ASSERT(field_type); |
| 2022 | BT_ASSERT(type->id == BT_FIELD_TYPE_ID_STRUCT); |
| 2023 | structure = container_of(type, struct bt_field_type_structure, parent); |
| 2024 | name_quark = g_quark_from_string(field_name); |
| 2025 | |
| 2026 | for (i = 0; i < structure->fields->len; i++) { |
| 2027 | struct structure_field *field = g_ptr_array_index( |
| 2028 | structure->fields, i); |
| 2029 | |
| 2030 | if (field->name == name_quark) { |
| 2031 | bt_put(field->type); |
| 2032 | field->type = bt_get(field_type); |
| 2033 | } |
| 2034 | } |
| 2035 | |
| 2036 | return ret; |
| 2037 | } |
| 2038 | |
| 2039 | int bt_field_type_structure_add_field(struct bt_field_type *type, |
| 2040 | struct bt_field_type *field_type, |
| 2041 | const char *field_name) |
| 2042 | { |
| 2043 | int ret = 0; |
| 2044 | struct bt_field_type_structure *structure; |
| 2045 | |
| 2046 | /* |
| 2047 | * TODO: check that `field_type` does not contain `type`, |
| 2048 | * recursively. |
| 2049 | */ |
| 2050 | if (!type) { |
| 2051 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2052 | ret = -1; |
| 2053 | goto end; |
| 2054 | } |
| 2055 | |
| 2056 | if (!field_name) { |
| 2057 | BT_LOGW_STR("Invalid parameter: field name is NULL."); |
| 2058 | ret = -1; |
| 2059 | goto end; |
| 2060 | } |
| 2061 | |
| 2062 | if (type->frozen) { |
| 2063 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 2064 | type); |
| 2065 | ret = -1; |
| 2066 | goto end; |
| 2067 | } |
| 2068 | |
| 2069 | if (type->id != BT_FIELD_TYPE_ID_STRUCT) { |
| 2070 | BT_LOGW("Invalid parameter: field type is not a structure field type: " |
| 2071 | "addr=%p, ft-id=%s", type, |
| 2072 | bt_field_type_id_string(type->id)); |
| 2073 | ret = -1; |
| 2074 | goto end; |
| 2075 | } |
| 2076 | |
| 2077 | if (type == field_type) { |
| 2078 | BT_LOGW("Invalid parameter: structure field type and field type to add are the same: " |
| 2079 | "addr=%p", type); |
| 2080 | ret = -1; |
| 2081 | goto end; |
| 2082 | } |
| 2083 | |
| 2084 | structure = container_of(type, |
| 2085 | struct bt_field_type_structure, parent); |
| 2086 | if (add_structure_field(structure->fields, |
| 2087 | structure->field_name_to_index, field_type, field_name)) { |
| 2088 | BT_LOGW("Cannot add field to structure field type: " |
| 2089 | "struct-ft-addr=%p, field-ft-addr=%p, field-name=\"%s\"", |
| 2090 | type, field_type, field_name); |
| 2091 | ret = -1; |
| 2092 | goto end; |
| 2093 | } |
| 2094 | |
| 2095 | BT_LOGV("Added structure field type field: struct-ft-addr=%p, " |
| 2096 | "field-ft-addr=%p, field-name=\"%s\"", type, |
| 2097 | field_type, field_name); |
| 2098 | end: |
| 2099 | return ret; |
| 2100 | } |
| 2101 | |
| 2102 | int64_t bt_field_type_structure_get_field_count( |
| 2103 | struct bt_field_type *type) |
| 2104 | { |
| 2105 | int64_t ret = 0; |
| 2106 | struct bt_field_type_structure *structure; |
| 2107 | |
| 2108 | if (!type) { |
| 2109 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2110 | ret = (int64_t) -1; |
| 2111 | goto end; |
| 2112 | } |
| 2113 | |
| 2114 | if (type->id != BT_FIELD_TYPE_ID_STRUCT) { |
| 2115 | BT_LOGW("Invalid parameter: field type is not a structure field type: " |
| 2116 | "addr=%p, ft-id=%s", type, |
| 2117 | bt_field_type_id_string(type->id)); |
| 2118 | ret = (int64_t) -1; |
| 2119 | goto end; |
| 2120 | } |
| 2121 | |
| 2122 | structure = container_of(type, struct bt_field_type_structure, |
| 2123 | parent); |
| 2124 | ret = (int64_t) structure->fields->len; |
| 2125 | end: |
| 2126 | return ret; |
| 2127 | } |
| 2128 | |
| 2129 | int bt_field_type_structure_get_field_by_index( |
| 2130 | struct bt_field_type *type, |
| 2131 | const char **field_name, struct bt_field_type **field_type, |
| 2132 | uint64_t index) |
| 2133 | { |
| 2134 | struct bt_field_type_structure *structure; |
| 2135 | struct structure_field *field; |
| 2136 | int ret = 0; |
| 2137 | |
| 2138 | if (!type) { |
| 2139 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2140 | ret = -1; |
| 2141 | goto end; |
| 2142 | } |
| 2143 | |
| 2144 | if (type->id != BT_FIELD_TYPE_ID_STRUCT) { |
| 2145 | BT_LOGW("Invalid parameter: field type is not a structure field type: " |
| 2146 | "addr=%p, ft-id=%s", type, |
| 2147 | bt_field_type_id_string(type->id)); |
| 2148 | ret = -1; |
| 2149 | goto end; |
| 2150 | } |
| 2151 | |
| 2152 | structure = container_of(type, struct bt_field_type_structure, |
| 2153 | parent); |
| 2154 | if (index >= structure->fields->len) { |
| 2155 | BT_LOGW("Invalid parameter: index is out of bounds: " |
| 2156 | "addr=%p, index=%" PRIu64 ", count=%u", |
| 2157 | type, index, structure->fields->len); |
| 2158 | ret = -1; |
| 2159 | goto end; |
| 2160 | } |
| 2161 | |
| 2162 | field = g_ptr_array_index(structure->fields, index); |
| 2163 | if (field_type) { |
| 2164 | *field_type = field->type; |
| 2165 | bt_get(field->type); |
| 2166 | } |
| 2167 | if (field_name) { |
| 2168 | *field_name = g_quark_to_string(field->name); |
| 2169 | BT_ASSERT(*field_name); |
| 2170 | } |
| 2171 | end: |
| 2172 | return ret; |
| 2173 | } |
| 2174 | |
| 2175 | struct bt_field_type *bt_field_type_structure_get_field_type_by_name( |
| 2176 | struct bt_field_type *type, |
| 2177 | const char *name) |
| 2178 | { |
| 2179 | size_t index; |
| 2180 | GQuark name_quark; |
| 2181 | struct structure_field *field; |
| 2182 | struct bt_field_type_structure *structure; |
| 2183 | struct bt_field_type *field_type = NULL; |
| 2184 | |
| 2185 | if (!type) { |
| 2186 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2187 | goto end; |
| 2188 | } |
| 2189 | |
| 2190 | if (!name) { |
| 2191 | BT_LOGW_STR("Invalid parameter: name is NULL."); |
| 2192 | goto end; |
| 2193 | } |
| 2194 | |
| 2195 | name_quark = g_quark_try_string(name); |
| 2196 | if (!name_quark) { |
| 2197 | BT_LOGV("No such structure field type field name: " |
| 2198 | "ft-addr=%p, field-name=\"%s\"", |
| 2199 | type, name); |
| 2200 | goto end; |
| 2201 | } |
| 2202 | |
| 2203 | structure = container_of(type, struct bt_field_type_structure, |
| 2204 | parent); |
| 2205 | if (!g_hash_table_lookup_extended(structure->field_name_to_index, |
| 2206 | GUINT_TO_POINTER(name_quark), NULL, (gpointer *)&index)) { |
| 2207 | BT_LOGV("No such structure field type field name: " |
| 2208 | "ft-addr=%p, field-name=\"%s\"", |
| 2209 | type, name); |
| 2210 | goto end; |
| 2211 | } |
| 2212 | |
| 2213 | field = structure->fields->pdata[index]; |
| 2214 | field_type = field->type; |
| 2215 | bt_get(field_type); |
| 2216 | end: |
| 2217 | return field_type; |
| 2218 | } |
| 2219 | |
| 2220 | struct bt_field_type *bt_field_type_variant_create( |
| 2221 | struct bt_field_type *enum_tag, const char *tag_name) |
| 2222 | { |
| 2223 | struct bt_field_type_variant *variant = NULL; |
| 2224 | |
| 2225 | BT_LOGD("Creating variant field type object: " |
| 2226 | "tag-ft-addr=%p, tag-field-name=\"%s\"", |
| 2227 | enum_tag, tag_name); |
| 2228 | |
| 2229 | if (tag_name && !bt_identifier_is_valid(tag_name)) { |
| 2230 | BT_LOGW("Invalid parameter: tag field name is not a valid CTF identifier: " |
| 2231 | "tag-ft-addr=%p, tag-field-name=\"%s\"", |
| 2232 | enum_tag, tag_name); |
| 2233 | goto error; |
| 2234 | } |
| 2235 | |
| 2236 | variant = g_new0(struct bt_field_type_variant, 1); |
| 2237 | if (!variant) { |
| 2238 | BT_LOGE_STR("Failed to allocate one variant field type."); |
| 2239 | goto error; |
| 2240 | } |
| 2241 | |
| 2242 | variant->parent.id = BT_FIELD_TYPE_ID_VARIANT; |
| 2243 | variant->tag_name = g_string_new(tag_name); |
| 2244 | variant->field_name_to_index = g_hash_table_new(NULL, NULL); |
| 2245 | variant->fields = g_ptr_array_new_with_free_func( |
| 2246 | (GDestroyNotify) destroy_structure_field); |
| 2247 | if (enum_tag) { |
| 2248 | bt_get(enum_tag); |
| 2249 | variant->tag = container_of(enum_tag, |
| 2250 | struct bt_field_type_enumeration, parent); |
| 2251 | } |
| 2252 | |
| 2253 | bt_field_type_init(&variant->parent, TRUE); |
| 2254 | /* A variant's alignment is undefined */ |
| 2255 | variant->parent.alignment = 0; |
| 2256 | BT_LOGD("Created variant field type object: addr=%p, " |
| 2257 | "tag-ft-addr=%p, tag-field-name=\"%s\"", |
| 2258 | &variant->parent, enum_tag, tag_name); |
| 2259 | return &variant->parent; |
| 2260 | error: |
| 2261 | return NULL; |
| 2262 | } |
| 2263 | |
| 2264 | struct bt_field_type *bt_field_type_variant_get_tag_type( |
| 2265 | struct bt_field_type *type) |
| 2266 | { |
| 2267 | struct bt_field_type_variant *variant; |
| 2268 | struct bt_field_type *tag_type = NULL; |
| 2269 | |
| 2270 | if (!type) { |
| 2271 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2272 | goto end; |
| 2273 | } |
| 2274 | |
| 2275 | if (type->id != BT_FIELD_TYPE_ID_VARIANT) { |
| 2276 | BT_LOGW("Invalid parameter: field type is not a variant field type: " |
| 2277 | "addr=%p, ft-id=%s", type, |
| 2278 | bt_field_type_id_string(type->id)); |
| 2279 | goto end; |
| 2280 | } |
| 2281 | |
| 2282 | variant = container_of(type, struct bt_field_type_variant, parent); |
| 2283 | if (!variant->tag) { |
| 2284 | BT_LOGV("Variant field type has no tag field type: " |
| 2285 | "addr=%p", type); |
| 2286 | goto end; |
| 2287 | } |
| 2288 | |
| 2289 | tag_type = &variant->tag->parent; |
| 2290 | bt_get(tag_type); |
| 2291 | end: |
| 2292 | return tag_type; |
| 2293 | } |
| 2294 | |
| 2295 | const char *bt_field_type_variant_get_tag_name( |
| 2296 | struct bt_field_type *type) |
| 2297 | { |
| 2298 | struct bt_field_type_variant *variant; |
| 2299 | const char *tag_name = NULL; |
| 2300 | |
| 2301 | if (!type) { |
| 2302 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2303 | goto end; |
| 2304 | } |
| 2305 | |
| 2306 | if (type->id != BT_FIELD_TYPE_ID_VARIANT) { |
| 2307 | BT_LOGW("Invalid parameter: field type is not a variant field type: " |
| 2308 | "addr=%p, ft-id=%s", type, |
| 2309 | bt_field_type_id_string(type->id)); |
| 2310 | goto end; |
| 2311 | } |
| 2312 | |
| 2313 | variant = container_of(type, struct bt_field_type_variant, parent); |
| 2314 | if (variant->tag_name->len == 0) { |
| 2315 | BT_LOGV("Variant field type has no tag field name: " |
| 2316 | "addr=%p", type); |
| 2317 | goto end; |
| 2318 | } |
| 2319 | |
| 2320 | tag_name = variant->tag_name->str; |
| 2321 | end: |
| 2322 | return tag_name; |
| 2323 | } |
| 2324 | |
| 2325 | int bt_field_type_variant_set_tag_name( |
| 2326 | struct bt_field_type *type, const char *name) |
| 2327 | { |
| 2328 | int ret = 0; |
| 2329 | struct bt_field_type_variant *variant; |
| 2330 | |
| 2331 | if (!type) { |
| 2332 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2333 | ret = -1; |
| 2334 | goto end; |
| 2335 | } |
| 2336 | |
| 2337 | if (type->frozen) { |
| 2338 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 2339 | type); |
| 2340 | ret = -1; |
| 2341 | goto end; |
| 2342 | } |
| 2343 | |
| 2344 | if (type->id != BT_FIELD_TYPE_ID_VARIANT) { |
| 2345 | BT_LOGW("Invalid parameter: field type is not a variant field type: " |
| 2346 | "addr=%p, ft-id=%s", type, |
| 2347 | bt_field_type_id_string(type->id)); |
| 2348 | ret = -1; |
| 2349 | goto end; |
| 2350 | } |
| 2351 | |
| 2352 | if (!bt_identifier_is_valid(name)) { |
| 2353 | BT_LOGW("Invalid parameter: tag field name is not a valid CTF identifier: " |
| 2354 | "variant-ft-addr=%p, tag-field-name=\"%s\"", |
| 2355 | type, name); |
| 2356 | ret = -1; |
| 2357 | goto end; |
| 2358 | } |
| 2359 | |
| 2360 | variant = container_of(type, struct bt_field_type_variant, parent); |
| 2361 | g_string_assign(variant->tag_name, name); |
| 2362 | BT_LOGV("Set variant field type's tag field name: addr=%p, " |
| 2363 | "tag-field-name=\"%s\"", type, name); |
| 2364 | end: |
| 2365 | return ret; |
| 2366 | } |
| 2367 | |
| 2368 | int bt_field_type_variant_add_field(struct bt_field_type *type, |
| 2369 | struct bt_field_type *field_type, |
| 2370 | const char *field_name) |
| 2371 | { |
| 2372 | size_t i; |
| 2373 | int ret = 0; |
| 2374 | struct bt_field_type_variant *variant; |
| 2375 | GQuark field_name_quark = g_quark_from_string(field_name); |
| 2376 | |
| 2377 | /* |
| 2378 | * TODO: check that `field_type` does not contain `type`, |
| 2379 | * recursively. |
| 2380 | */ |
| 2381 | if (!type) { |
| 2382 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2383 | ret = -1; |
| 2384 | goto end; |
| 2385 | } |
| 2386 | |
| 2387 | if (type->frozen) { |
| 2388 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 2389 | type); |
| 2390 | ret = -1; |
| 2391 | goto end; |
| 2392 | } |
| 2393 | |
| 2394 | if (type->id != BT_FIELD_TYPE_ID_VARIANT) { |
| 2395 | BT_LOGW("Invalid parameter: field type is not a variant field type: " |
| 2396 | "addr=%p, ft-id=%s", type, |
| 2397 | bt_field_type_id_string(type->id)); |
| 2398 | ret = -1; |
| 2399 | goto end; |
| 2400 | } |
| 2401 | |
| 2402 | if (type == field_type) { |
| 2403 | BT_LOGW("Invalid parameter: variant field type and field type to add are the same: " |
| 2404 | "addr=%p", type); |
| 2405 | ret = -1; |
| 2406 | goto end; |
| 2407 | } |
| 2408 | |
| 2409 | variant = container_of(type, struct bt_field_type_variant, parent); |
| 2410 | |
| 2411 | /* The user has explicitly provided a tag; validate against it. */ |
| 2412 | if (variant->tag) { |
| 2413 | int name_found = 0; |
| 2414 | |
| 2415 | /* Make sure this name is present in the enum tag */ |
| 2416 | for (i = 0; i < variant->tag->entries->len; i++) { |
| 2417 | struct enumeration_mapping *mapping = |
| 2418 | g_ptr_array_index(variant->tag->entries, i); |
| 2419 | |
| 2420 | if (mapping->string == field_name_quark) { |
| 2421 | name_found = 1; |
| 2422 | break; |
| 2423 | } |
| 2424 | } |
| 2425 | |
| 2426 | if (!name_found) { |
| 2427 | /* Validation failed */ |
| 2428 | BT_LOGW("Invalid parameter: field name does not name a tag field type's mapping: " |
| 2429 | "variant-ft-addr=%p, tag-ft-addr=%p, " |
| 2430 | "tag-field-name=\"%s\"" |
| 2431 | "field-ft-addr=%p, field-name=\"%s\"", |
| 2432 | type, variant->tag, variant->tag_name->str, |
| 2433 | field_type, field_name); |
| 2434 | ret = -1; |
| 2435 | goto end; |
| 2436 | } |
| 2437 | } |
| 2438 | |
| 2439 | if (add_structure_field(variant->fields, variant->field_name_to_index, |
| 2440 | field_type, field_name)) { |
| 2441 | BT_LOGW("Cannot add field to variant field type: " |
| 2442 | "variant-ft-addr=%p, field-ft-addr=%p, field-name=\"%s\"", |
| 2443 | type, field_type, field_name); |
| 2444 | ret = -1; |
| 2445 | goto end; |
| 2446 | } |
| 2447 | |
| 2448 | BT_LOGV("Added variant field type field: variant-ft-addr=%p, " |
| 2449 | "field-ft-addr=%p, field-name=\"%s\"", type, |
| 2450 | field_type, field_name); |
| 2451 | |
| 2452 | end: |
| 2453 | return ret; |
| 2454 | } |
| 2455 | |
| 2456 | struct bt_field_type *bt_field_type_variant_get_field_type_by_name( |
| 2457 | struct bt_field_type *type, |
| 2458 | const char *field_name) |
| 2459 | { |
| 2460 | size_t index; |
| 2461 | GQuark name_quark; |
| 2462 | struct structure_field *field; |
| 2463 | struct bt_field_type_variant *variant; |
| 2464 | struct bt_field_type *field_type = NULL; |
| 2465 | |
| 2466 | if (!type) { |
| 2467 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2468 | goto end; |
| 2469 | } |
| 2470 | |
| 2471 | if (!field_name) { |
| 2472 | BT_LOGW_STR("Invalid parameter: field name is NULL."); |
| 2473 | goto end; |
| 2474 | } |
| 2475 | |
| 2476 | name_quark = g_quark_try_string(field_name); |
| 2477 | if (!name_quark) { |
| 2478 | BT_LOGV("No such variant field type field name: " |
| 2479 | "ft-addr=%p, field-name=\"%s\"", |
| 2480 | type, field_name); |
| 2481 | goto end; |
| 2482 | } |
| 2483 | |
| 2484 | variant = container_of(type, struct bt_field_type_variant, parent); |
| 2485 | if (!g_hash_table_lookup_extended(variant->field_name_to_index, |
| 2486 | GUINT_TO_POINTER(name_quark), NULL, (gpointer *)&index)) { |
| 2487 | BT_LOGV("No such variant field type field name: " |
| 2488 | "ft-addr=%p, field-name=\"%s\"", |
| 2489 | type, field_name); |
| 2490 | goto end; |
| 2491 | } |
| 2492 | |
| 2493 | field = g_ptr_array_index(variant->fields, index); |
| 2494 | field_type = field->type; |
| 2495 | bt_get(field_type); |
| 2496 | end: |
| 2497 | return field_type; |
| 2498 | } |
| 2499 | |
| 2500 | struct bt_field_type *bt_field_type_variant_get_field_type_from_tag( |
| 2501 | struct bt_field_type *type, |
| 2502 | struct bt_field *tag) |
| 2503 | { |
| 2504 | int ret; |
| 2505 | const char *enum_value; |
| 2506 | struct bt_field_type *field_type = NULL; |
| 2507 | struct bt_field_type_enumeration_mapping_iterator *iter = NULL; |
| 2508 | |
| 2509 | if (!type) { |
| 2510 | BT_LOGW_STR("Invalid parameter: variant field type is NULL."); |
| 2511 | goto end; |
| 2512 | } |
| 2513 | |
| 2514 | if (!tag) { |
| 2515 | BT_LOGW_STR("Invalid parameter: tag field is NULL."); |
| 2516 | goto end; |
| 2517 | } |
| 2518 | |
| 2519 | if (type->id != BT_FIELD_TYPE_ID_VARIANT) { |
| 2520 | BT_LOGW("Invalid parameter: field type is not a variant field type: " |
| 2521 | "addr=%p, ft-id=%s", type, |
| 2522 | bt_field_type_id_string(type->id)); |
| 2523 | goto end; |
| 2524 | } |
| 2525 | |
| 2526 | iter = bt_field_enumeration_get_mappings(tag); |
| 2527 | ret = bt_field_type_enumeration_mapping_iterator_next(iter); |
| 2528 | if (!iter || ret) { |
| 2529 | BT_LOGW("Cannot get enumeration field type mapping iterator from enumeration field: " |
| 2530 | "enum-field-addr=%p", tag); |
| 2531 | goto end; |
| 2532 | } |
| 2533 | |
| 2534 | ret = bt_field_type_enumeration_mapping_iterator_get_signed(iter, |
| 2535 | &enum_value, NULL, NULL); |
| 2536 | if (ret) { |
| 2537 | BT_LOGW("Cannot get enumeration field type mapping iterator's current mapping: " |
| 2538 | "iter-addr=%p", iter); |
| 2539 | goto end; |
| 2540 | } |
| 2541 | |
| 2542 | field_type = bt_field_type_variant_get_field_type_by_name( |
| 2543 | type, enum_value); |
| 2544 | end: |
| 2545 | bt_put(iter); |
| 2546 | return field_type; |
| 2547 | } |
| 2548 | |
| 2549 | int64_t bt_field_type_variant_get_field_count(struct bt_field_type *type) |
| 2550 | { |
| 2551 | int64_t ret = 0; |
| 2552 | struct bt_field_type_variant *variant; |
| 2553 | |
| 2554 | if (!type) { |
| 2555 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2556 | ret = (int64_t) -1; |
| 2557 | goto end; |
| 2558 | } |
| 2559 | |
| 2560 | if (type->id != BT_FIELD_TYPE_ID_VARIANT) { |
| 2561 | BT_LOGW("Invalid parameter: field type is not a variant field type: " |
| 2562 | "addr=%p, ft-id=%s", type, |
| 2563 | bt_field_type_id_string(type->id)); |
| 2564 | ret = (int64_t) -1; |
| 2565 | goto end; |
| 2566 | } |
| 2567 | |
| 2568 | variant = container_of(type, struct bt_field_type_variant, |
| 2569 | parent); |
| 2570 | ret = (int64_t) variant->fields->len; |
| 2571 | end: |
| 2572 | return ret; |
| 2573 | |
| 2574 | } |
| 2575 | |
| 2576 | int bt_field_type_variant_get_field_by_index(struct bt_field_type *type, |
| 2577 | const char **field_name, struct bt_field_type **field_type, |
| 2578 | uint64_t index) |
| 2579 | { |
| 2580 | struct bt_field_type_variant *variant; |
| 2581 | struct structure_field *field; |
| 2582 | int ret = 0; |
| 2583 | |
| 2584 | if (!type) { |
| 2585 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2586 | ret = -1; |
| 2587 | goto end; |
| 2588 | } |
| 2589 | |
| 2590 | if (type->id != BT_FIELD_TYPE_ID_VARIANT) { |
| 2591 | BT_LOGW("Invalid parameter: field type is not a variant field type: " |
| 2592 | "addr=%p, ft-id=%s", type, |
| 2593 | bt_field_type_id_string(type->id)); |
| 2594 | ret = -1; |
| 2595 | goto end; |
| 2596 | } |
| 2597 | |
| 2598 | variant = container_of(type, struct bt_field_type_variant, |
| 2599 | parent); |
| 2600 | if (index >= variant->fields->len) { |
| 2601 | BT_LOGW("Invalid parameter: index is out of bounds: " |
| 2602 | "addr=%p, index=%" PRIu64 ", count=%u", |
| 2603 | type, index, variant->fields->len); |
| 2604 | ret = -1; |
| 2605 | goto end; |
| 2606 | } |
| 2607 | |
| 2608 | field = g_ptr_array_index(variant->fields, index); |
| 2609 | if (field_type) { |
| 2610 | *field_type = field->type; |
| 2611 | bt_get(field->type); |
| 2612 | } |
| 2613 | if (field_name) { |
| 2614 | *field_name = g_quark_to_string(field->name); |
| 2615 | BT_ASSERT(*field_name); |
| 2616 | } |
| 2617 | end: |
| 2618 | return ret; |
| 2619 | } |
| 2620 | |
| 2621 | struct bt_field_type *bt_field_type_array_create( |
| 2622 | struct bt_field_type *element_type, |
| 2623 | unsigned int length) |
| 2624 | { |
| 2625 | struct bt_field_type_array *array = NULL; |
| 2626 | |
| 2627 | BT_LOGD("Creating array field type object: element-ft-addr=%p, " |
| 2628 | "length=%u", element_type, length); |
| 2629 | |
| 2630 | if (!element_type) { |
| 2631 | BT_LOGW_STR("Invalid parameter: element field type is NULL."); |
| 2632 | goto error; |
| 2633 | } |
| 2634 | |
| 2635 | if (length == 0) { |
| 2636 | BT_LOGW_STR("Invalid parameter: length is zero."); |
| 2637 | goto error; |
| 2638 | } |
| 2639 | |
| 2640 | array = g_new0(struct bt_field_type_array, 1); |
| 2641 | if (!array) { |
| 2642 | BT_LOGE_STR("Failed to allocate one array field type."); |
| 2643 | goto error; |
| 2644 | } |
| 2645 | |
| 2646 | array->parent.id = BT_FIELD_TYPE_ID_ARRAY; |
| 2647 | bt_get(element_type); |
| 2648 | array->element_type = element_type; |
| 2649 | array->length = length; |
| 2650 | bt_field_type_init(&array->parent, FALSE); |
| 2651 | BT_LOGD("Created array field type object: addr=%p, " |
| 2652 | "element-ft-addr=%p, length=%u", |
| 2653 | &array->parent, element_type, length); |
| 2654 | return &array->parent; |
| 2655 | error: |
| 2656 | return NULL; |
| 2657 | } |
| 2658 | |
| 2659 | struct bt_field_type *bt_field_type_array_get_element_type( |
| 2660 | struct bt_field_type *type) |
| 2661 | { |
| 2662 | struct bt_field_type *ret = NULL; |
| 2663 | struct bt_field_type_array *array; |
| 2664 | |
| 2665 | if (!type) { |
| 2666 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2667 | goto end; |
| 2668 | } |
| 2669 | |
| 2670 | if (type->id != BT_FIELD_TYPE_ID_ARRAY) { |
| 2671 | BT_LOGW("Invalid parameter: field type is not an array field type: " |
| 2672 | "addr=%p, ft-id=%s", type, |
| 2673 | bt_field_type_id_string(type->id)); |
| 2674 | goto end; |
| 2675 | } |
| 2676 | |
| 2677 | array = container_of(type, struct bt_field_type_array, parent); |
| 2678 | ret = array->element_type; |
| 2679 | bt_get(ret); |
| 2680 | end: |
| 2681 | return ret; |
| 2682 | } |
| 2683 | |
| 2684 | BT_HIDDEN |
| 2685 | int bt_field_type_array_set_element_type(struct bt_field_type *type, |
| 2686 | struct bt_field_type *element_type) |
| 2687 | { |
| 2688 | int ret = 0; |
| 2689 | struct bt_field_type_array *array; |
| 2690 | |
| 2691 | if (!type) { |
| 2692 | BT_LOGW_STR("Invalid parameter: array field type is NULL."); |
| 2693 | ret = -1; |
| 2694 | goto end; |
| 2695 | } |
| 2696 | |
| 2697 | if (!element_type) { |
| 2698 | BT_LOGW_STR("Invalid parameter: element field type is NULL."); |
| 2699 | ret = -1; |
| 2700 | goto end; |
| 2701 | } |
| 2702 | |
| 2703 | if (type->id != BT_FIELD_TYPE_ID_ARRAY) { |
| 2704 | BT_LOGW("Invalid parameter: field type is not an array field type: " |
| 2705 | "addr=%p, ft-id=%s", type, |
| 2706 | bt_field_type_id_string(type->id)); |
| 2707 | ret = -1; |
| 2708 | goto end; |
| 2709 | } |
| 2710 | |
| 2711 | array = container_of(type, struct bt_field_type_array, parent); |
| 2712 | |
| 2713 | if (array->element_type) { |
| 2714 | BT_PUT(array->element_type); |
| 2715 | } |
| 2716 | |
| 2717 | array->element_type = element_type; |
| 2718 | bt_get(array->element_type); |
| 2719 | BT_LOGV("Set array field type's element field type: array-ft-addr=%p, " |
| 2720 | "element-ft-addr=%p", type, element_type); |
| 2721 | |
| 2722 | end: |
| 2723 | return ret; |
| 2724 | } |
| 2725 | |
| 2726 | int64_t bt_field_type_array_get_length(struct bt_field_type *type) |
| 2727 | { |
| 2728 | int64_t ret; |
| 2729 | struct bt_field_type_array *array; |
| 2730 | |
| 2731 | if (!type) { |
| 2732 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2733 | ret = (int64_t) -1; |
| 2734 | goto end; |
| 2735 | } |
| 2736 | |
| 2737 | if (type->id != BT_FIELD_TYPE_ID_ARRAY) { |
| 2738 | BT_LOGW("Invalid parameter: field type is not an array field type: " |
| 2739 | "addr=%p, ft-id=%s", type, |
| 2740 | bt_field_type_id_string(type->id)); |
| 2741 | ret = (int64_t) -1; |
| 2742 | goto end; |
| 2743 | } |
| 2744 | |
| 2745 | array = container_of(type, struct bt_field_type_array, parent); |
| 2746 | ret = (int64_t) array->length; |
| 2747 | end: |
| 2748 | return ret; |
| 2749 | } |
| 2750 | |
| 2751 | struct bt_field_type *bt_field_type_sequence_create( |
| 2752 | struct bt_field_type *element_type, |
| 2753 | const char *length_field_name) |
| 2754 | { |
| 2755 | struct bt_field_type_sequence *sequence = NULL; |
| 2756 | |
| 2757 | BT_LOGD("Creating sequence field type object: element-ft-addr=%p, " |
| 2758 | "length-field-name=\"%s\"", element_type, length_field_name); |
| 2759 | |
| 2760 | if (!element_type) { |
| 2761 | BT_LOGW_STR("Invalid parameter: element field type is NULL."); |
| 2762 | goto error; |
| 2763 | } |
| 2764 | |
| 2765 | if (!bt_identifier_is_valid(length_field_name)) { |
| 2766 | BT_LOGW("Invalid parameter: length field name is not a valid CTF identifier: " |
| 2767 | "length-field-name=\"%s\"", length_field_name); |
| 2768 | goto error; |
| 2769 | } |
| 2770 | |
| 2771 | sequence = g_new0(struct bt_field_type_sequence, 1); |
| 2772 | if (!sequence) { |
| 2773 | BT_LOGE_STR("Failed to allocate one sequence field type."); |
| 2774 | goto error; |
| 2775 | } |
| 2776 | |
| 2777 | sequence->parent.id = BT_FIELD_TYPE_ID_SEQUENCE; |
| 2778 | bt_get(element_type); |
| 2779 | sequence->element_type = element_type; |
| 2780 | sequence->length_field_name = g_string_new(length_field_name); |
| 2781 | bt_field_type_init(&sequence->parent, FALSE); |
| 2782 | BT_LOGD("Created sequence field type object: addr=%p, " |
| 2783 | "element-ft-addr=%p, length-field-name=\"%s\"", |
| 2784 | &sequence->parent, element_type, length_field_name); |
| 2785 | return &sequence->parent; |
| 2786 | error: |
| 2787 | return NULL; |
| 2788 | } |
| 2789 | |
| 2790 | struct bt_field_type *bt_field_type_sequence_get_element_type( |
| 2791 | struct bt_field_type *type) |
| 2792 | { |
| 2793 | struct bt_field_type *ret = NULL; |
| 2794 | struct bt_field_type_sequence *sequence; |
| 2795 | |
| 2796 | if (!type) { |
| 2797 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2798 | goto end; |
| 2799 | } |
| 2800 | |
| 2801 | if (type->id != BT_FIELD_TYPE_ID_SEQUENCE) { |
| 2802 | BT_LOGW("Invalid parameter: field type is not a sequence field type: " |
| 2803 | "addr=%p, ft-id=%s", type, |
| 2804 | bt_field_type_id_string(type->id)); |
| 2805 | goto end; |
| 2806 | } |
| 2807 | |
| 2808 | sequence = container_of(type, struct bt_field_type_sequence, |
| 2809 | parent); |
| 2810 | ret = sequence->element_type; |
| 2811 | bt_get(ret); |
| 2812 | end: |
| 2813 | return ret; |
| 2814 | } |
| 2815 | |
| 2816 | BT_HIDDEN |
| 2817 | int bt_field_type_sequence_set_element_type(struct bt_field_type *type, |
| 2818 | struct bt_field_type *element_type) |
| 2819 | { |
| 2820 | int ret = 0; |
| 2821 | struct bt_field_type_sequence *sequence; |
| 2822 | |
| 2823 | if (!type) { |
| 2824 | BT_LOGW_STR("Invalid parameter: sequence field type is NULL."); |
| 2825 | ret = -1; |
| 2826 | goto end; |
| 2827 | } |
| 2828 | |
| 2829 | if (!element_type) { |
| 2830 | BT_LOGW_STR("Invalid parameter: element field type is NULL."); |
| 2831 | ret = -1; |
| 2832 | goto end; |
| 2833 | } |
| 2834 | |
| 2835 | if (type->id != BT_FIELD_TYPE_ID_SEQUENCE) { |
| 2836 | BT_LOGW("Invalid parameter: field type is not a sequence field type: " |
| 2837 | "addr=%p, ft-id=%s", type, |
| 2838 | bt_field_type_id_string(type->id)); |
| 2839 | ret = -1; |
| 2840 | goto end; |
| 2841 | } |
| 2842 | |
| 2843 | sequence = container_of(type, struct bt_field_type_sequence, parent); |
| 2844 | if (sequence->element_type) { |
| 2845 | BT_PUT(sequence->element_type); |
| 2846 | } |
| 2847 | |
| 2848 | sequence->element_type = element_type; |
| 2849 | bt_get(sequence->element_type); |
| 2850 | BT_LOGV("Set sequence field type's element field type: sequence-ft-addr=%p, " |
| 2851 | "element-ft-addr=%p", type, element_type); |
| 2852 | |
| 2853 | end: |
| 2854 | return ret; |
| 2855 | } |
| 2856 | |
| 2857 | const char *bt_field_type_sequence_get_length_field_name( |
| 2858 | struct bt_field_type *type) |
| 2859 | { |
| 2860 | const char *ret = NULL; |
| 2861 | struct bt_field_type_sequence *sequence; |
| 2862 | |
| 2863 | if (!type) { |
| 2864 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2865 | goto end; |
| 2866 | } |
| 2867 | |
| 2868 | if (type->id != BT_FIELD_TYPE_ID_SEQUENCE) { |
| 2869 | BT_LOGW("Invalid parameter: field type is not a sequence field type: " |
| 2870 | "addr=%p, ft-id=%s", type, |
| 2871 | bt_field_type_id_string(type->id)); |
| 2872 | goto end; |
| 2873 | } |
| 2874 | |
| 2875 | sequence = container_of(type, struct bt_field_type_sequence, |
| 2876 | parent); |
| 2877 | ret = sequence->length_field_name->str; |
| 2878 | end: |
| 2879 | return ret; |
| 2880 | } |
| 2881 | |
| 2882 | struct bt_field_type *bt_field_type_string_create(void) |
| 2883 | { |
| 2884 | struct bt_field_type_string *string = |
| 2885 | g_new0(struct bt_field_type_string, 1); |
| 2886 | |
| 2887 | BT_LOGD_STR("Creating string field type object."); |
| 2888 | |
| 2889 | if (!string) { |
| 2890 | BT_LOGE_STR("Failed to allocate one string field type."); |
| 2891 | return NULL; |
| 2892 | } |
| 2893 | |
| 2894 | string->parent.id = BT_FIELD_TYPE_ID_STRING; |
| 2895 | bt_field_type_init(&string->parent, TRUE); |
| 2896 | string->encoding = BT_STRING_ENCODING_UTF8; |
| 2897 | string->parent.alignment = CHAR_BIT; |
| 2898 | BT_LOGD("Created string field type object: addr=%p", &string->parent); |
| 2899 | return &string->parent; |
| 2900 | } |
| 2901 | |
| 2902 | enum bt_string_encoding bt_field_type_string_get_encoding( |
| 2903 | struct bt_field_type *type) |
| 2904 | { |
| 2905 | struct bt_field_type_string *string; |
| 2906 | enum bt_string_encoding ret = BT_STRING_ENCODING_UNKNOWN; |
| 2907 | |
| 2908 | if (!type) { |
| 2909 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2910 | goto end; |
| 2911 | } |
| 2912 | |
| 2913 | if (type->id != BT_FIELD_TYPE_ID_STRING) { |
| 2914 | BT_LOGW("Invalid parameter: field type is not a string field type: " |
| 2915 | "addr=%p, ft-id=%s", type, |
| 2916 | bt_field_type_id_string(type->id)); |
| 2917 | goto end; |
| 2918 | } |
| 2919 | |
| 2920 | string = container_of(type, struct bt_field_type_string, |
| 2921 | parent); |
| 2922 | ret = string->encoding; |
| 2923 | end: |
| 2924 | return ret; |
| 2925 | } |
| 2926 | |
| 2927 | int bt_field_type_string_set_encoding(struct bt_field_type *type, |
| 2928 | enum bt_string_encoding encoding) |
| 2929 | { |
| 2930 | int ret = 0; |
| 2931 | struct bt_field_type_string *string; |
| 2932 | |
| 2933 | if (!type) { |
| 2934 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2935 | ret = -1; |
| 2936 | goto end; |
| 2937 | } |
| 2938 | |
| 2939 | if (type->id != BT_FIELD_TYPE_ID_STRING) { |
| 2940 | BT_LOGW("Invalid parameter: field type is not a string field type: " |
| 2941 | "addr=%p, ft-id=%s", type, |
| 2942 | bt_field_type_id_string(type->id)); |
| 2943 | ret = -1; |
| 2944 | goto end; |
| 2945 | } |
| 2946 | |
| 2947 | if (encoding != BT_STRING_ENCODING_UTF8 && |
| 2948 | encoding != BT_STRING_ENCODING_ASCII) { |
| 2949 | BT_LOGW("Invalid parameter: unknown string encoding: " |
| 2950 | "addr=%p, encoding=%d", type, encoding); |
| 2951 | ret = -1; |
| 2952 | goto end; |
| 2953 | } |
| 2954 | |
| 2955 | string = container_of(type, struct bt_field_type_string, parent); |
| 2956 | string->encoding = encoding; |
| 2957 | BT_LOGV("Set string field type's encoding: addr=%p, encoding=%s", |
| 2958 | type, bt_string_encoding_string(encoding)); |
| 2959 | end: |
| 2960 | return ret; |
| 2961 | } |
| 2962 | |
| 2963 | int bt_field_type_get_alignment(struct bt_field_type *type) |
| 2964 | { |
| 2965 | int ret; |
| 2966 | enum bt_field_type_id type_id; |
| 2967 | |
| 2968 | if (!type) { |
| 2969 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 2970 | ret = -1; |
| 2971 | goto end; |
| 2972 | } |
| 2973 | |
| 2974 | if (type->frozen) { |
| 2975 | ret = (int) type->alignment; |
| 2976 | goto end; |
| 2977 | } |
| 2978 | |
| 2979 | type_id = bt_field_type_get_type_id(type); |
| 2980 | switch (type_id) { |
| 2981 | case BT_FIELD_TYPE_ID_SEQUENCE: |
| 2982 | { |
| 2983 | struct bt_field_type *element = |
| 2984 | bt_field_type_sequence_get_element_type(type); |
| 2985 | |
| 2986 | BT_ASSERT(element); |
| 2987 | ret = bt_field_type_get_alignment(element); |
| 2988 | bt_put(element); |
| 2989 | break; |
| 2990 | } |
| 2991 | case BT_FIELD_TYPE_ID_ARRAY: |
| 2992 | { |
| 2993 | struct bt_field_type *element = |
| 2994 | bt_field_type_array_get_element_type(type); |
| 2995 | |
| 2996 | BT_ASSERT(element); |
| 2997 | ret = bt_field_type_get_alignment(element); |
| 2998 | bt_put(element); |
| 2999 | break; |
| 3000 | } |
| 3001 | case BT_FIELD_TYPE_ID_STRUCT: |
| 3002 | { |
| 3003 | int64_t i, element_count; |
| 3004 | |
| 3005 | element_count = bt_field_type_structure_get_field_count( |
| 3006 | type); |
| 3007 | BT_ASSERT(element_count >= 0); |
| 3008 | |
| 3009 | for (i = 0; i < element_count; i++) { |
| 3010 | struct bt_field_type *field = NULL; |
| 3011 | int field_alignment; |
| 3012 | |
| 3013 | ret = bt_field_type_structure_get_field_by_index( |
| 3014 | type, NULL, &field, i); |
| 3015 | BT_ASSERT(ret == 0); |
| 3016 | BT_ASSERT(field); |
| 3017 | field_alignment = bt_field_type_get_alignment( |
| 3018 | field); |
| 3019 | bt_put(field); |
| 3020 | if (field_alignment < 0) { |
| 3021 | ret = field_alignment; |
| 3022 | goto end; |
| 3023 | } |
| 3024 | |
| 3025 | type->alignment = MAX(field_alignment, type->alignment); |
| 3026 | } |
| 3027 | ret = (int) type->alignment; |
| 3028 | break; |
| 3029 | } |
| 3030 | case BT_FIELD_TYPE_ID_ENUM: |
| 3031 | { |
| 3032 | struct bt_field_type *container = |
| 3033 | bt_field_type_enumeration_get_container_type(type); |
| 3034 | |
| 3035 | ret = bt_field_type_get_alignment(container); |
| 3036 | bt_put(container); |
| 3037 | break; |
| 3038 | } |
| 3039 | case BT_FIELD_TYPE_ID_UNKNOWN: |
| 3040 | BT_LOGW("Invalid parameter: unknown field type ID: " |
| 3041 | "addr=%p, ft-id=%d", type, type_id); |
| 3042 | ret = -1; |
| 3043 | break; |
| 3044 | default: |
| 3045 | ret = (int) type->alignment; |
| 3046 | break; |
| 3047 | } |
| 3048 | end: |
| 3049 | return ret; |
| 3050 | } |
| 3051 | |
| 3052 | static inline |
| 3053 | int is_power_of_two(unsigned int value) |
| 3054 | { |
| 3055 | return ((value & (value - 1)) == 0) && value > 0; |
| 3056 | } |
| 3057 | |
| 3058 | int bt_field_type_set_alignment(struct bt_field_type *type, |
| 3059 | unsigned int alignment) |
| 3060 | { |
| 3061 | int ret = 0; |
| 3062 | enum bt_field_type_id type_id; |
| 3063 | |
| 3064 | /* Alignment must be a power of two */ |
| 3065 | if (!type) { |
| 3066 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 3067 | ret = -1; |
| 3068 | goto end; |
| 3069 | } |
| 3070 | |
| 3071 | if (type->frozen) { |
| 3072 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 3073 | type); |
| 3074 | ret = -1; |
| 3075 | goto end; |
| 3076 | } |
| 3077 | |
| 3078 | if (!is_power_of_two(alignment)) { |
| 3079 | BT_LOGW("Invalid parameter: alignment is not a power of two: " |
| 3080 | "addr=%p, align=%u", type, alignment); |
| 3081 | ret = -1; |
| 3082 | goto end; |
| 3083 | } |
| 3084 | |
| 3085 | type_id = bt_field_type_get_type_id(type); |
| 3086 | if (type_id == BT_FIELD_TYPE_ID_UNKNOWN) { |
| 3087 | BT_LOGW("Invalid parameter: unknown field type ID: " |
| 3088 | "addr=%p, ft-id=%d", type, type_id); |
| 3089 | ret = -1; |
| 3090 | goto end; |
| 3091 | } |
| 3092 | |
| 3093 | if (type->id == BT_FIELD_TYPE_ID_STRING && |
| 3094 | alignment != CHAR_BIT) { |
| 3095 | BT_LOGW("Invalid parameter: alignment must be %u for a string field type: " |
| 3096 | "addr=%p, align=%u", CHAR_BIT, type, alignment); |
| 3097 | ret = -1; |
| 3098 | goto end; |
| 3099 | } |
| 3100 | |
| 3101 | if (type_id == BT_FIELD_TYPE_ID_VARIANT || |
| 3102 | type_id == BT_FIELD_TYPE_ID_SEQUENCE || |
| 3103 | type_id == BT_FIELD_TYPE_ID_ARRAY) { |
| 3104 | /* Setting an alignment on these types makes no sense */ |
| 3105 | BT_LOGW("Invalid parameter: cannot set the alignment of this field type: " |
| 3106 | "addr=%p, ft-id=%s", type, |
| 3107 | bt_field_type_id_string(type->id)); |
| 3108 | ret = -1; |
| 3109 | goto end; |
| 3110 | } |
| 3111 | |
| 3112 | type->alignment = alignment; |
| 3113 | ret = 0; |
| 3114 | BT_LOGV("Set field type's alignment: addr=%p, align=%u", |
| 3115 | type, alignment); |
| 3116 | end: |
| 3117 | return ret; |
| 3118 | } |
| 3119 | |
| 3120 | enum bt_byte_order bt_field_type_get_byte_order( |
| 3121 | struct bt_field_type *type) |
| 3122 | { |
| 3123 | enum bt_byte_order ret = BT_BYTE_ORDER_UNKNOWN; |
| 3124 | |
| 3125 | if (!type) { |
| 3126 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 3127 | goto end; |
| 3128 | } |
| 3129 | |
| 3130 | switch (type->id) { |
| 3131 | case BT_FIELD_TYPE_ID_INTEGER: |
| 3132 | { |
| 3133 | struct bt_field_type_integer *integer = container_of( |
| 3134 | type, struct bt_field_type_integer, parent); |
| 3135 | ret = integer->user_byte_order; |
| 3136 | break; |
| 3137 | } |
| 3138 | case BT_FIELD_TYPE_ID_ENUM: |
| 3139 | { |
| 3140 | struct bt_field_type_enumeration *enum_ft = container_of( |
| 3141 | type, struct bt_field_type_enumeration, parent); |
| 3142 | ret = bt_field_type_get_byte_order(enum_ft->container); |
| 3143 | break; |
| 3144 | } |
| 3145 | case BT_FIELD_TYPE_ID_FLOAT: |
| 3146 | { |
| 3147 | struct bt_field_type_floating_point *floating_point = |
| 3148 | container_of(type, |
| 3149 | struct bt_field_type_floating_point, |
| 3150 | parent); |
| 3151 | ret = floating_point->user_byte_order; |
| 3152 | break; |
| 3153 | } |
| 3154 | default: |
| 3155 | BT_LOGW("Invalid parameter: cannot get the byte order of this field type: " |
| 3156 | "addr=%p, ft-id=%s", type, |
| 3157 | bt_field_type_id_string(type->id)); |
| 3158 | goto end; |
| 3159 | } |
| 3160 | |
| 3161 | BT_ASSERT(ret == BT_BYTE_ORDER_NATIVE || |
| 3162 | ret == BT_BYTE_ORDER_LITTLE_ENDIAN || |
| 3163 | ret == BT_BYTE_ORDER_BIG_ENDIAN || |
| 3164 | ret == BT_BYTE_ORDER_NETWORK); |
| 3165 | |
| 3166 | end: |
| 3167 | return ret; |
| 3168 | } |
| 3169 | |
| 3170 | int bt_field_type_set_byte_order(struct bt_field_type *type, |
| 3171 | enum bt_byte_order byte_order) |
| 3172 | { |
| 3173 | int ret = 0; |
| 3174 | |
| 3175 | if (!type) { |
| 3176 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 3177 | ret = -1; |
| 3178 | goto end; |
| 3179 | } |
| 3180 | |
| 3181 | if (type->frozen) { |
| 3182 | BT_LOGW("Invalid parameter: field type is frozen: addr=%p", |
| 3183 | type); |
| 3184 | ret = -1; |
| 3185 | goto end; |
| 3186 | } |
| 3187 | |
| 3188 | if (byte_order != BT_BYTE_ORDER_NATIVE && |
| 3189 | byte_order != BT_BYTE_ORDER_LITTLE_ENDIAN && |
| 3190 | byte_order != BT_BYTE_ORDER_BIG_ENDIAN && |
| 3191 | byte_order != BT_BYTE_ORDER_NETWORK) { |
| 3192 | BT_LOGW("Invalid parameter: invalid byte order: " |
| 3193 | "addr=%p, bo=%s", type, |
| 3194 | bt_byte_order_string(byte_order)); |
| 3195 | ret = -1; |
| 3196 | goto end; |
| 3197 | } |
| 3198 | |
| 3199 | if (set_byte_order_funcs[type->id]) { |
| 3200 | set_byte_order_funcs[type->id](type, byte_order); |
| 3201 | } |
| 3202 | |
| 3203 | BT_LOGV("Set field type's byte order: addr=%p, bo=%s", |
| 3204 | type, bt_byte_order_string(byte_order)); |
| 3205 | |
| 3206 | end: |
| 3207 | return ret; |
| 3208 | } |
| 3209 | |
| 3210 | enum bt_field_type_id bt_field_type_get_type_id( |
| 3211 | struct bt_field_type *type) |
| 3212 | { |
| 3213 | if (!type) { |
| 3214 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 3215 | return BT_FIELD_TYPE_ID_UNKNOWN; |
| 3216 | } |
| 3217 | |
| 3218 | return type->id; |
| 3219 | } |
| 3220 | |
| 3221 | int bt_field_type_is_integer(struct bt_field_type *type) |
| 3222 | { |
| 3223 | return bt_field_type_get_type_id(type) == BT_FIELD_TYPE_ID_INTEGER; |
| 3224 | } |
| 3225 | |
| 3226 | int bt_field_type_is_floating_point(struct bt_field_type *type) |
| 3227 | { |
| 3228 | return bt_field_type_get_type_id(type) == BT_FIELD_TYPE_ID_FLOAT; |
| 3229 | } |
| 3230 | |
| 3231 | int bt_field_type_is_enumeration(struct bt_field_type *type) |
| 3232 | { |
| 3233 | return bt_field_type_get_type_id(type) == BT_FIELD_TYPE_ID_ENUM; |
| 3234 | } |
| 3235 | |
| 3236 | int bt_field_type_is_string(struct bt_field_type *type) |
| 3237 | { |
| 3238 | return bt_field_type_get_type_id(type) == BT_FIELD_TYPE_ID_STRING; |
| 3239 | } |
| 3240 | |
| 3241 | int bt_field_type_is_structure(struct bt_field_type *type) |
| 3242 | { |
| 3243 | return bt_field_type_get_type_id(type) == BT_FIELD_TYPE_ID_STRUCT; |
| 3244 | } |
| 3245 | |
| 3246 | int bt_field_type_is_array(struct bt_field_type *type) |
| 3247 | { |
| 3248 | return bt_field_type_get_type_id(type) == BT_FIELD_TYPE_ID_ARRAY; |
| 3249 | } |
| 3250 | |
| 3251 | int bt_field_type_is_sequence(struct bt_field_type *type) |
| 3252 | { |
| 3253 | return bt_field_type_get_type_id(type) == BT_FIELD_TYPE_ID_SEQUENCE; |
| 3254 | } |
| 3255 | |
| 3256 | int bt_field_type_is_variant(struct bt_field_type *type) |
| 3257 | { |
| 3258 | return bt_field_type_get_type_id(type) == BT_FIELD_TYPE_ID_VARIANT; |
| 3259 | } |
| 3260 | |
| 3261 | /* Pre-2.0 CTF writer backward compatibility */ |
| 3262 | void bt_ctf_field_type_get(struct bt_field_type *type) |
| 3263 | { |
| 3264 | bt_get(type); |
| 3265 | } |
| 3266 | |
| 3267 | /* Pre-2.0 CTF writer backward compatibility */ |
| 3268 | void bt_ctf_field_type_put(struct bt_field_type *type) |
| 3269 | { |
| 3270 | bt_put(type); |
| 3271 | } |
| 3272 | |
| 3273 | BT_HIDDEN |
| 3274 | void _bt_field_type_freeze(struct bt_field_type *type) |
| 3275 | { |
| 3276 | if (!type || type->frozen) { |
| 3277 | return; |
| 3278 | } |
| 3279 | |
| 3280 | type->freeze(type); |
| 3281 | } |
| 3282 | |
| 3283 | BT_HIDDEN |
| 3284 | struct bt_field_type *bt_field_type_variant_get_field_type_signed( |
| 3285 | struct bt_field_type_variant *variant, |
| 3286 | int64_t tag_value) |
| 3287 | { |
| 3288 | struct bt_field_type *type = NULL; |
| 3289 | GQuark field_name_quark; |
| 3290 | gpointer index; |
| 3291 | struct structure_field *field_entry; |
| 3292 | struct range_overlap_query query = { |
| 3293 | .range_start._signed = tag_value, |
| 3294 | .range_end._signed = tag_value, |
| 3295 | .mapping_name = 0, |
| 3296 | .overlaps = 0, |
| 3297 | }; |
| 3298 | |
| 3299 | g_ptr_array_foreach(variant->tag->entries, check_ranges_overlap, |
| 3300 | &query); |
| 3301 | if (!query.overlaps) { |
| 3302 | goto end; |
| 3303 | } |
| 3304 | |
| 3305 | field_name_quark = query.mapping_name; |
| 3306 | if (!g_hash_table_lookup_extended(variant->field_name_to_index, |
| 3307 | GUINT_TO_POINTER(field_name_quark), NULL, &index)) { |
| 3308 | goto end; |
| 3309 | } |
| 3310 | |
| 3311 | field_entry = g_ptr_array_index(variant->fields, (size_t) index); |
| 3312 | type = field_entry->type; |
| 3313 | end: |
| 3314 | return type; |
| 3315 | } |
| 3316 | |
| 3317 | BT_HIDDEN |
| 3318 | struct bt_field_type *bt_field_type_variant_get_field_type_unsigned( |
| 3319 | struct bt_field_type_variant *variant, |
| 3320 | uint64_t tag_value) |
| 3321 | { |
| 3322 | struct bt_field_type *type = NULL; |
| 3323 | GQuark field_name_quark; |
| 3324 | gpointer index; |
| 3325 | struct structure_field *field_entry; |
| 3326 | struct range_overlap_query query = { |
| 3327 | .range_start._unsigned = tag_value, |
| 3328 | .range_end._unsigned = tag_value, |
| 3329 | .mapping_name = 0, |
| 3330 | .overlaps = 0, |
| 3331 | }; |
| 3332 | |
| 3333 | g_ptr_array_foreach(variant->tag->entries, |
| 3334 | check_ranges_overlap_unsigned, |
| 3335 | &query); |
| 3336 | if (!query.overlaps) { |
| 3337 | goto end; |
| 3338 | } |
| 3339 | |
| 3340 | field_name_quark = query.mapping_name; |
| 3341 | if (!g_hash_table_lookup_extended(variant->field_name_to_index, |
| 3342 | GUINT_TO_POINTER(field_name_quark), NULL, &index)) { |
| 3343 | goto end; |
| 3344 | } |
| 3345 | |
| 3346 | field_entry = g_ptr_array_index(variant->fields, (size_t)index); |
| 3347 | type = field_entry->type; |
| 3348 | end: |
| 3349 | return type; |
| 3350 | } |
| 3351 | |
| 3352 | BT_HIDDEN |
| 3353 | int bt_field_type_serialize(struct bt_field_type *type, |
| 3354 | struct metadata_context *context) |
| 3355 | { |
| 3356 | int ret; |
| 3357 | |
| 3358 | BT_ASSERT(type); |
| 3359 | BT_ASSERT(context); |
| 3360 | |
| 3361 | /* Make sure field type is valid before serializing it */ |
| 3362 | ret = bt_field_type_validate(type); |
| 3363 | if (ret) { |
| 3364 | BT_LOGW("Cannot serialize field type's metadata: field type is invalid: " |
| 3365 | "addr=%p", type); |
| 3366 | goto end; |
| 3367 | } |
| 3368 | |
| 3369 | ret = type->serialize(type, context); |
| 3370 | end: |
| 3371 | return ret; |
| 3372 | } |
| 3373 | |
| 3374 | struct bt_field_type *bt_field_type_copy(struct bt_field_type *type) |
| 3375 | { |
| 3376 | struct bt_field_type *copy = NULL; |
| 3377 | |
| 3378 | if (!type) { |
| 3379 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 3380 | goto end; |
| 3381 | } |
| 3382 | |
| 3383 | copy = type_copy_funcs[type->id](type); |
| 3384 | if (!copy) { |
| 3385 | BT_LOGE_STR("Cannot copy field type."); |
| 3386 | goto end; |
| 3387 | } |
| 3388 | |
| 3389 | copy->alignment = type->alignment; |
| 3390 | end: |
| 3391 | return copy; |
| 3392 | } |
| 3393 | |
| 3394 | BT_HIDDEN |
| 3395 | int bt_field_type_structure_get_field_name_index( |
| 3396 | struct bt_field_type *type, const char *name) |
| 3397 | { |
| 3398 | int ret; |
| 3399 | size_t index; |
| 3400 | GQuark name_quark; |
| 3401 | struct bt_field_type_structure *structure; |
| 3402 | |
| 3403 | if (!type) { |
| 3404 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 3405 | ret = -1; |
| 3406 | goto end; |
| 3407 | } |
| 3408 | |
| 3409 | if (!name) { |
| 3410 | BT_LOGW_STR("Invalid parameter: field name is NULL."); |
| 3411 | ret = -1; |
| 3412 | goto end; |
| 3413 | } |
| 3414 | |
| 3415 | if (bt_field_type_get_type_id(type) != BT_FIELD_TYPE_ID_STRUCT) { |
| 3416 | BT_LOGW("Invalid parameter: field type is not a structure field type: " |
| 3417 | "addr=%p, ft-id=%s", type, |
| 3418 | bt_field_type_id_string(type->id)); |
| 3419 | ret = -1; |
| 3420 | goto end; |
| 3421 | } |
| 3422 | |
| 3423 | name_quark = g_quark_try_string(name); |
| 3424 | if (!name_quark) { |
| 3425 | BT_LOGV("No such structure field type field name: " |
| 3426 | "ft-addr=%p, field-name=\"%s\"", |
| 3427 | type, name); |
| 3428 | ret = -1; |
| 3429 | goto end; |
| 3430 | } |
| 3431 | |
| 3432 | structure = container_of(type, struct bt_field_type_structure, |
| 3433 | parent); |
| 3434 | if (!g_hash_table_lookup_extended(structure->field_name_to_index, |
| 3435 | GUINT_TO_POINTER(name_quark), |
| 3436 | NULL, (gpointer *)&index)) { |
| 3437 | BT_LOGV("No such structure field type field name: " |
| 3438 | "ft-addr=%p, field-name=\"%s\"", |
| 3439 | type, name); |
| 3440 | ret = -1; |
| 3441 | goto end; |
| 3442 | } |
| 3443 | ret = (int) index; |
| 3444 | end: |
| 3445 | return ret; |
| 3446 | } |
| 3447 | |
| 3448 | BT_HIDDEN |
| 3449 | int bt_field_type_variant_get_field_name_index( |
| 3450 | struct bt_field_type *type, const char *name) |
| 3451 | { |
| 3452 | int ret; |
| 3453 | size_t index; |
| 3454 | GQuark name_quark; |
| 3455 | struct bt_field_type_variant *variant; |
| 3456 | |
| 3457 | if (!type) { |
| 3458 | BT_LOGW_STR("Invalid parameter: variant field type is NULL."); |
| 3459 | ret = -1; |
| 3460 | goto end; |
| 3461 | } |
| 3462 | |
| 3463 | if (!name) { |
| 3464 | BT_LOGW_STR("Invalid parameter: field name is NULL."); |
| 3465 | ret = -1; |
| 3466 | goto end; |
| 3467 | } |
| 3468 | |
| 3469 | if (bt_field_type_get_type_id(type) != BT_FIELD_TYPE_ID_VARIANT) { |
| 3470 | BT_LOGW("Invalid parameter: field type is not a variant field type: " |
| 3471 | "addr=%p, ft-id=%s", type, |
| 3472 | bt_field_type_id_string(type->id)); |
| 3473 | ret = -1; |
| 3474 | goto end; |
| 3475 | } |
| 3476 | |
| 3477 | name_quark = g_quark_try_string(name); |
| 3478 | if (!name_quark) { |
| 3479 | BT_LOGV("No such variant field type field name: " |
| 3480 | "ft-addr=%p, field-name=\"%s\"", |
| 3481 | type, name); |
| 3482 | ret = -1; |
| 3483 | goto end; |
| 3484 | } |
| 3485 | |
| 3486 | variant = container_of(type, struct bt_field_type_variant, |
| 3487 | parent); |
| 3488 | if (!g_hash_table_lookup_extended(variant->field_name_to_index, |
| 3489 | GUINT_TO_POINTER(name_quark), |
| 3490 | NULL, (gpointer *)&index)) { |
| 3491 | BT_LOGV("No such variant field type field name: " |
| 3492 | "ft-addr=%p, field-name=\"%s\"", |
| 3493 | type, name); |
| 3494 | ret = -1; |
| 3495 | goto end; |
| 3496 | } |
| 3497 | ret = (int) index; |
| 3498 | end: |
| 3499 | return ret; |
| 3500 | } |
| 3501 | |
| 3502 | BT_HIDDEN |
| 3503 | int bt_field_type_sequence_set_length_field_path( |
| 3504 | struct bt_field_type *type, |
| 3505 | struct bt_field_path *path) |
| 3506 | { |
| 3507 | int ret = 0; |
| 3508 | struct bt_field_type_sequence *sequence; |
| 3509 | |
| 3510 | if (!type) { |
| 3511 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 3512 | ret = -1; |
| 3513 | goto end; |
| 3514 | } |
| 3515 | |
| 3516 | if (bt_field_type_get_type_id(type) != BT_FIELD_TYPE_ID_SEQUENCE) { |
| 3517 | BT_LOGW("Invalid parameter: field type is not a sequence field type: " |
| 3518 | "addr=%p, ft-id=%s", type, |
| 3519 | bt_field_type_id_string(type->id)); |
| 3520 | ret = -1; |
| 3521 | goto end; |
| 3522 | } |
| 3523 | |
| 3524 | sequence = container_of(type, struct bt_field_type_sequence, |
| 3525 | parent); |
| 3526 | bt_get(path); |
| 3527 | BT_MOVE(sequence->length_field_path, path); |
| 3528 | BT_LOGV("Set sequence field type's length field path: ft-addr=%p, " |
| 3529 | "field-path-addr=%p", type, path); |
| 3530 | end: |
| 3531 | return ret; |
| 3532 | } |
| 3533 | |
| 3534 | BT_HIDDEN |
| 3535 | int bt_field_type_variant_set_tag_field_path(struct bt_field_type *type, |
| 3536 | struct bt_field_path *path) |
| 3537 | { |
| 3538 | int ret = 0; |
| 3539 | struct bt_field_type_variant *variant; |
| 3540 | |
| 3541 | if (!type) { |
| 3542 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 3543 | ret = -1; |
| 3544 | goto end; |
| 3545 | } |
| 3546 | |
| 3547 | if (bt_field_type_get_type_id(type) != BT_FIELD_TYPE_ID_VARIANT) { |
| 3548 | BT_LOGW("Invalid parameter: field type is not a variant field type: " |
| 3549 | "addr=%p, ft-id=%s", type, |
| 3550 | bt_field_type_id_string(type->id)); |
| 3551 | ret = -1; |
| 3552 | goto end; |
| 3553 | } |
| 3554 | |
| 3555 | variant = container_of(type, struct bt_field_type_variant, |
| 3556 | parent); |
| 3557 | bt_get(path); |
| 3558 | BT_MOVE(variant->tag_field_path, path); |
| 3559 | BT_LOGV("Set variant field type's tag field path: ft-addr=%p, " |
| 3560 | "field-path-addr=%p", type, path); |
| 3561 | end: |
| 3562 | return ret; |
| 3563 | } |
| 3564 | |
| 3565 | BT_HIDDEN |
| 3566 | int bt_field_type_variant_set_tag_field_type(struct bt_field_type *type, |
| 3567 | struct bt_field_type *tag) |
| 3568 | { |
| 3569 | int ret = 0; |
| 3570 | struct bt_field_type_variant *variant; |
| 3571 | |
| 3572 | if (!type) { |
| 3573 | BT_LOGW_STR("Invalid parameter: variant field type is NULL."); |
| 3574 | ret = -1; |
| 3575 | goto end; |
| 3576 | } |
| 3577 | |
| 3578 | if (!tag) { |
| 3579 | BT_LOGW_STR("Invalid parameter: tag field type is NULL."); |
| 3580 | ret = -1; |
| 3581 | goto end; |
| 3582 | } |
| 3583 | |
| 3584 | if (bt_field_type_get_type_id(tag) != BT_FIELD_TYPE_ID_ENUM) { |
| 3585 | BT_LOGW("Invalid parameter: field type is not an enumeration field type: " |
| 3586 | "addr=%p, ft-id=%s", type, |
| 3587 | bt_field_type_id_string(type->id)); |
| 3588 | ret = -1; |
| 3589 | goto end; |
| 3590 | } |
| 3591 | |
| 3592 | variant = container_of(type, struct bt_field_type_variant, |
| 3593 | parent); |
| 3594 | bt_get(tag); |
| 3595 | if (variant->tag) { |
| 3596 | bt_put(&variant->tag->parent); |
| 3597 | } |
| 3598 | variant->tag = container_of(tag, struct bt_field_type_enumeration, |
| 3599 | parent); |
| 3600 | BT_LOGV("Set variant field type's tag field type: variant-ft-addr=%p, " |
| 3601 | "tag-ft-addr=%p", type, tag); |
| 3602 | end: |
| 3603 | return ret; |
| 3604 | } |
| 3605 | |
| 3606 | static |
| 3607 | void bt_field_type_integer_destroy(struct bt_field_type *type) |
| 3608 | { |
| 3609 | struct bt_field_type_integer *integer = |
| 3610 | (struct bt_field_type_integer *) type; |
| 3611 | |
| 3612 | if (!type) { |
| 3613 | return; |
| 3614 | } |
| 3615 | |
| 3616 | BT_LOGD("Destroying integer field type object: addr=%p", type); |
| 3617 | BT_LOGD_STR("Putting mapped clock class."); |
| 3618 | bt_put(integer->mapped_clock); |
| 3619 | g_free(integer); |
| 3620 | } |
| 3621 | |
| 3622 | static |
| 3623 | void bt_field_type_enumeration_destroy(struct bt_field_type *type) |
| 3624 | { |
| 3625 | struct bt_field_type_enumeration *enumeration = |
| 3626 | (struct bt_field_type_enumeration *) type; |
| 3627 | |
| 3628 | if (!type) { |
| 3629 | return; |
| 3630 | } |
| 3631 | |
| 3632 | BT_LOGD("Destroying enumeration field type object: addr=%p", type); |
| 3633 | g_ptr_array_free(enumeration->entries, TRUE); |
| 3634 | BT_LOGD_STR("Putting container field type."); |
| 3635 | bt_put(enumeration->container); |
| 3636 | g_free(enumeration); |
| 3637 | } |
| 3638 | |
| 3639 | static |
| 3640 | void bt_field_type_floating_point_destroy(struct bt_field_type *type) |
| 3641 | { |
| 3642 | struct bt_field_type_floating_point *floating_point = |
| 3643 | (struct bt_field_type_floating_point *) type; |
| 3644 | |
| 3645 | if (!type) { |
| 3646 | return; |
| 3647 | } |
| 3648 | |
| 3649 | BT_LOGD("Destroying floating point number field type object: addr=%p", type); |
| 3650 | g_free(floating_point); |
| 3651 | } |
| 3652 | |
| 3653 | static |
| 3654 | void bt_field_type_structure_destroy(struct bt_field_type *type) |
| 3655 | { |
| 3656 | struct bt_field_type_structure *structure = |
| 3657 | (struct bt_field_type_structure *) type; |
| 3658 | |
| 3659 | if (!type) { |
| 3660 | return; |
| 3661 | } |
| 3662 | |
| 3663 | BT_LOGD("Destroying structure field type object: addr=%p", type); |
| 3664 | g_ptr_array_free(structure->fields, TRUE); |
| 3665 | g_hash_table_destroy(structure->field_name_to_index); |
| 3666 | g_free(structure); |
| 3667 | } |
| 3668 | |
| 3669 | static |
| 3670 | void bt_field_type_variant_destroy(struct bt_field_type *type) |
| 3671 | { |
| 3672 | struct bt_field_type_variant *variant = |
| 3673 | (struct bt_field_type_variant *) type; |
| 3674 | |
| 3675 | if (!type) { |
| 3676 | return; |
| 3677 | } |
| 3678 | |
| 3679 | BT_LOGD("Destroying variant field type object: addr=%p", type); |
| 3680 | g_ptr_array_free(variant->fields, TRUE); |
| 3681 | g_hash_table_destroy(variant->field_name_to_index); |
| 3682 | g_string_free(variant->tag_name, TRUE); |
| 3683 | BT_LOGD_STR("Putting tag field type."); |
| 3684 | bt_put(&variant->tag->parent); |
| 3685 | BT_PUT(variant->tag_field_path); |
| 3686 | g_free(variant); |
| 3687 | } |
| 3688 | |
| 3689 | static |
| 3690 | void bt_field_type_array_destroy(struct bt_field_type *type) |
| 3691 | { |
| 3692 | struct bt_field_type_array *array = |
| 3693 | (struct bt_field_type_array *) type; |
| 3694 | |
| 3695 | if (!type) { |
| 3696 | return; |
| 3697 | } |
| 3698 | |
| 3699 | BT_LOGD("Destroying array field type object: addr=%p", type); |
| 3700 | BT_LOGD_STR("Putting element field type."); |
| 3701 | bt_put(array->element_type); |
| 3702 | g_free(array); |
| 3703 | } |
| 3704 | |
| 3705 | static |
| 3706 | void bt_field_type_sequence_destroy(struct bt_field_type *type) |
| 3707 | { |
| 3708 | struct bt_field_type_sequence *sequence = |
| 3709 | (struct bt_field_type_sequence *) type; |
| 3710 | |
| 3711 | if (!type) { |
| 3712 | return; |
| 3713 | } |
| 3714 | |
| 3715 | BT_LOGD("Destroying sequence field type object: addr=%p", type); |
| 3716 | BT_LOGD_STR("Putting element field type."); |
| 3717 | bt_put(sequence->element_type); |
| 3718 | g_string_free(sequence->length_field_name, TRUE); |
| 3719 | BT_LOGD_STR("Putting length field path."); |
| 3720 | BT_PUT(sequence->length_field_path); |
| 3721 | g_free(sequence); |
| 3722 | } |
| 3723 | |
| 3724 | static |
| 3725 | void bt_field_type_string_destroy(struct bt_field_type *type) |
| 3726 | { |
| 3727 | struct bt_field_type_string *string = |
| 3728 | (struct bt_field_type_string *) type; |
| 3729 | |
| 3730 | if (!type) { |
| 3731 | return; |
| 3732 | } |
| 3733 | |
| 3734 | BT_LOGD("Destroying string field type object: addr=%p", type); |
| 3735 | g_free(string); |
| 3736 | } |
| 3737 | |
| 3738 | static |
| 3739 | void generic_field_type_freeze(struct bt_field_type *type) |
| 3740 | { |
| 3741 | type->frozen = 1; |
| 3742 | } |
| 3743 | |
| 3744 | static |
| 3745 | void bt_field_type_integer_freeze(struct bt_field_type *type) |
| 3746 | { |
| 3747 | struct bt_field_type_integer *integer_type = container_of( |
| 3748 | type, struct bt_field_type_integer, parent); |
| 3749 | |
| 3750 | BT_LOGD("Freezing integer field type object: addr=%p", type); |
| 3751 | |
| 3752 | if (integer_type->mapped_clock) { |
| 3753 | BT_LOGD_STR("Freezing integer field type's mapped clock class."); |
| 3754 | bt_clock_class_freeze(integer_type->mapped_clock); |
| 3755 | } |
| 3756 | |
| 3757 | generic_field_type_freeze(type); |
| 3758 | } |
| 3759 | |
| 3760 | static |
| 3761 | void bt_field_type_enumeration_freeze(struct bt_field_type *type) |
| 3762 | { |
| 3763 | struct bt_field_type_enumeration *enumeration_type = container_of( |
| 3764 | type, struct bt_field_type_enumeration, parent); |
| 3765 | |
| 3766 | BT_LOGD("Freezing enumeration field type object: addr=%p", type); |
| 3767 | type->alignment = bt_field_type_get_alignment(type); |
| 3768 | set_enumeration_range_overlap(type); |
| 3769 | generic_field_type_freeze(type); |
| 3770 | BT_LOGD("Freezing enumeration field type object's container field type: int-ft-addr=%p", |
| 3771 | enumeration_type->container); |
| 3772 | bt_field_type_freeze(enumeration_type->container); |
| 3773 | } |
| 3774 | |
| 3775 | static |
| 3776 | void freeze_structure_field(struct structure_field *field) |
| 3777 | { |
| 3778 | BT_LOGD("Freezing structure/variant field type field: field-addr=%p, " |
| 3779 | "field-ft-addr=%p, field-name=\"%s\"", field, |
| 3780 | field->type, g_quark_to_string(field->name)); |
| 3781 | bt_field_type_freeze(field->type); |
| 3782 | } |
| 3783 | |
| 3784 | static |
| 3785 | void bt_field_type_structure_freeze(struct bt_field_type *type) |
| 3786 | { |
| 3787 | struct bt_field_type_structure *structure_type = container_of( |
| 3788 | type, struct bt_field_type_structure, parent); |
| 3789 | |
| 3790 | /* Cache the alignment */ |
| 3791 | BT_LOGD("Freezing structure field type object: addr=%p", type); |
| 3792 | type->alignment = bt_field_type_get_alignment(type); |
| 3793 | generic_field_type_freeze(type); |
| 3794 | g_ptr_array_foreach(structure_type->fields, |
| 3795 | (GFunc) freeze_structure_field, NULL); |
| 3796 | } |
| 3797 | |
| 3798 | static |
| 3799 | void bt_field_type_variant_freeze(struct bt_field_type *type) |
| 3800 | { |
| 3801 | struct bt_field_type_variant *variant_type = container_of( |
| 3802 | type, struct bt_field_type_variant, parent); |
| 3803 | |
| 3804 | BT_LOGD("Freezing variant field type object: addr=%p", type); |
| 3805 | generic_field_type_freeze(type); |
| 3806 | g_ptr_array_foreach(variant_type->fields, |
| 3807 | (GFunc) freeze_structure_field, NULL); |
| 3808 | } |
| 3809 | |
| 3810 | static |
| 3811 | void bt_field_type_array_freeze(struct bt_field_type *type) |
| 3812 | { |
| 3813 | struct bt_field_type_array *array_type = container_of( |
| 3814 | type, struct bt_field_type_array, parent); |
| 3815 | |
| 3816 | /* Cache the alignment */ |
| 3817 | BT_LOGD("Freezing array field type object: addr=%p", type); |
| 3818 | type->alignment = bt_field_type_get_alignment(type); |
| 3819 | generic_field_type_freeze(type); |
| 3820 | BT_LOGD("Freezing array field type object's element field type: element-ft-addr=%p", |
| 3821 | array_type->element_type); |
| 3822 | bt_field_type_freeze(array_type->element_type); |
| 3823 | } |
| 3824 | |
| 3825 | static |
| 3826 | void bt_field_type_sequence_freeze(struct bt_field_type *type) |
| 3827 | { |
| 3828 | struct bt_field_type_sequence *sequence_type = container_of( |
| 3829 | type, struct bt_field_type_sequence, parent); |
| 3830 | |
| 3831 | /* Cache the alignment */ |
| 3832 | BT_LOGD("Freezing sequence field type object: addr=%p", type); |
| 3833 | type->alignment = bt_field_type_get_alignment(type); |
| 3834 | generic_field_type_freeze(type); |
| 3835 | BT_LOGD("Freezing sequence field type object's element field type: element-ft-addr=%p", |
| 3836 | sequence_type->element_type); |
| 3837 | bt_field_type_freeze(sequence_type->element_type); |
| 3838 | } |
| 3839 | |
| 3840 | static |
| 3841 | const char *get_encoding_string(enum bt_string_encoding encoding) |
| 3842 | { |
| 3843 | const char *encoding_string; |
| 3844 | |
| 3845 | switch (encoding) { |
| 3846 | case BT_STRING_ENCODING_NONE: |
| 3847 | encoding_string = "none"; |
| 3848 | break; |
| 3849 | case BT_STRING_ENCODING_ASCII: |
| 3850 | encoding_string = "ASCII"; |
| 3851 | break; |
| 3852 | case BT_STRING_ENCODING_UTF8: |
| 3853 | encoding_string = "UTF8"; |
| 3854 | break; |
| 3855 | default: |
| 3856 | encoding_string = "unknown"; |
| 3857 | break; |
| 3858 | } |
| 3859 | |
| 3860 | return encoding_string; |
| 3861 | } |
| 3862 | |
| 3863 | static |
| 3864 | const char *get_integer_base_string(enum bt_integer_base base) |
| 3865 | { |
| 3866 | const char *base_string; |
| 3867 | |
| 3868 | switch (base) { |
| 3869 | case BT_INTEGER_BASE_DECIMAL: |
| 3870 | case BT_INTEGER_BASE_UNSPECIFIED: |
| 3871 | base_string = "decimal"; |
| 3872 | break; |
| 3873 | case BT_INTEGER_BASE_HEXADECIMAL: |
| 3874 | base_string = "hexadecimal"; |
| 3875 | break; |
| 3876 | case BT_INTEGER_BASE_OCTAL: |
| 3877 | base_string = "octal"; |
| 3878 | break; |
| 3879 | case BT_INTEGER_BASE_BINARY: |
| 3880 | base_string = "binary"; |
| 3881 | break; |
| 3882 | default: |
| 3883 | base_string = "unknown"; |
| 3884 | break; |
| 3885 | } |
| 3886 | |
| 3887 | return base_string; |
| 3888 | } |
| 3889 | |
| 3890 | static |
| 3891 | void append_field_name(struct metadata_context *context, |
| 3892 | const char *name) |
| 3893 | { |
| 3894 | g_string_append_c(context->string, ' '); |
| 3895 | |
| 3896 | if (!bt_identifier_is_valid(name) || *name == '_') { |
| 3897 | g_string_append_c(context->string, '_'); |
| 3898 | } |
| 3899 | |
| 3900 | g_string_append(context->string, name); |
| 3901 | } |
| 3902 | |
| 3903 | static |
| 3904 | int bt_field_type_integer_serialize(struct bt_field_type *type, |
| 3905 | struct metadata_context *context) |
| 3906 | { |
| 3907 | struct bt_field_type_integer *integer = container_of(type, |
| 3908 | struct bt_field_type_integer, parent); |
| 3909 | int ret = 0; |
| 3910 | |
| 3911 | BT_LOGD("Serializing integer field type's metadata: " |
| 3912 | "ft-addr=%p, metadata-context-addr=%p", type, context); |
| 3913 | g_string_append_printf(context->string, |
| 3914 | "integer { size = %u; align = %u; signed = %s; encoding = %s; base = %s; byte_order = %s", |
| 3915 | integer->size, type->alignment, |
| 3916 | (integer->is_signed ? "true" : "false"), |
| 3917 | get_encoding_string(integer->encoding), |
| 3918 | get_integer_base_string(integer->base), |
| 3919 | get_byte_order_string(integer->user_byte_order)); |
| 3920 | if (integer->mapped_clock) { |
| 3921 | const char *clock_name = bt_clock_class_get_name( |
| 3922 | integer->mapped_clock); |
| 3923 | |
| 3924 | BT_ASSERT(clock_name); |
| 3925 | g_string_append_printf(context->string, |
| 3926 | "; map = clock.%s.value", clock_name); |
| 3927 | } |
| 3928 | |
| 3929 | g_string_append(context->string, "; }"); |
| 3930 | return ret; |
| 3931 | } |
| 3932 | |
| 3933 | static |
| 3934 | int bt_field_type_enumeration_serialize(struct bt_field_type *type, |
| 3935 | struct metadata_context *context) |
| 3936 | { |
| 3937 | size_t entry; |
| 3938 | int ret; |
| 3939 | struct bt_field_type_enumeration *enumeration = container_of(type, |
| 3940 | struct bt_field_type_enumeration, parent); |
| 3941 | struct bt_field_type *container_type; |
| 3942 | int container_signed; |
| 3943 | |
| 3944 | BT_LOGD("Serializing enumeration field type's metadata: " |
| 3945 | "ft-addr=%p, metadata-context-addr=%p", type, context); |
| 3946 | container_type = bt_field_type_enumeration_get_container_type(type); |
| 3947 | BT_ASSERT(container_type); |
| 3948 | container_signed = bt_ctf_field_type_integer_get_signed(container_type); |
| 3949 | BT_ASSERT(container_signed >= 0); |
| 3950 | g_string_append(context->string, "enum : "); |
| 3951 | BT_LOGD_STR("Serializing enumeration field type's container field type's metadata."); |
| 3952 | ret = bt_field_type_serialize(enumeration->container, context); |
| 3953 | if (ret) { |
| 3954 | BT_LOGW("Cannot serialize enumeration field type's container field type's metadata: " |
| 3955 | "container-ft-addr=%p", enumeration->container); |
| 3956 | goto end; |
| 3957 | } |
| 3958 | |
| 3959 | g_string_append(context->string, " { "); |
| 3960 | for (entry = 0; entry < enumeration->entries->len; entry++) { |
| 3961 | struct enumeration_mapping *mapping = |
| 3962 | enumeration->entries->pdata[entry]; |
| 3963 | const char *label = g_quark_to_string(mapping->string); |
| 3964 | |
| 3965 | g_string_append(context->string, "\""); |
| 3966 | |
| 3967 | if (!bt_identifier_is_valid(label) || label[0] == '_') { |
| 3968 | g_string_append(context->string, "_"); |
| 3969 | } |
| 3970 | |
| 3971 | g_string_append_printf(context->string, "%s\" = ", label); |
| 3972 | |
| 3973 | if (container_signed) { |
| 3974 | if (mapping->range_start._signed == |
| 3975 | mapping->range_end._signed) { |
| 3976 | g_string_append_printf(context->string, |
| 3977 | "%" PRId64, |
| 3978 | mapping->range_start._signed); |
| 3979 | } else { |
| 3980 | g_string_append_printf(context->string, |
| 3981 | "%" PRId64 " ... %" PRId64, |
| 3982 | mapping->range_start._signed, |
| 3983 | mapping->range_end._signed); |
| 3984 | } |
| 3985 | } else { |
| 3986 | if (mapping->range_start._unsigned == |
| 3987 | mapping->range_end._unsigned) { |
| 3988 | g_string_append_printf(context->string, |
| 3989 | "%" PRIu64, |
| 3990 | mapping->range_start._unsigned); |
| 3991 | } else { |
| 3992 | g_string_append_printf(context->string, |
| 3993 | "%" PRIu64 " ... %" PRIu64, |
| 3994 | mapping->range_start._unsigned, |
| 3995 | mapping->range_end._unsigned); |
| 3996 | } |
| 3997 | } |
| 3998 | |
| 3999 | g_string_append(context->string, |
| 4000 | ((entry != (enumeration->entries->len - 1)) ? |
| 4001 | ", " : " }")); |
| 4002 | } |
| 4003 | |
| 4004 | if (context->field_name->len) { |
| 4005 | append_field_name(context, |
| 4006 | context->field_name->str); |
| 4007 | g_string_assign(context->field_name, ""); |
| 4008 | } |
| 4009 | end: |
| 4010 | bt_put(container_type); |
| 4011 | return ret; |
| 4012 | } |
| 4013 | |
| 4014 | static |
| 4015 | int bt_field_type_floating_point_serialize(struct bt_field_type *type, |
| 4016 | struct metadata_context *context) |
| 4017 | { |
| 4018 | struct bt_field_type_floating_point *floating_point = container_of( |
| 4019 | type, struct bt_field_type_floating_point, parent); |
| 4020 | |
| 4021 | BT_LOGD("Serializing floating point number field type's metadata: " |
| 4022 | "ft-addr=%p, metadata-context-addr=%p", type, context); |
| 4023 | g_string_append_printf(context->string, |
| 4024 | "floating_point { exp_dig = %u; mant_dig = %u; byte_order = %s; align = %u; }", |
| 4025 | floating_point->exp_dig, |
| 4026 | floating_point->mant_dig, |
| 4027 | get_byte_order_string(floating_point->user_byte_order), |
| 4028 | type->alignment); |
| 4029 | return 0; |
| 4030 | } |
| 4031 | |
| 4032 | static |
| 4033 | int bt_field_type_structure_serialize(struct bt_field_type *type, |
| 4034 | struct metadata_context *context) |
| 4035 | { |
| 4036 | size_t i; |
| 4037 | unsigned int indent; |
| 4038 | int ret = 0; |
| 4039 | struct bt_field_type_structure *structure = container_of(type, |
| 4040 | struct bt_field_type_structure, parent); |
| 4041 | GString *structure_field_name = context->field_name; |
| 4042 | |
| 4043 | BT_LOGD("Serializing structure field type's metadata: " |
| 4044 | "ft-addr=%p, metadata-context-addr=%p", type, context); |
| 4045 | context->field_name = g_string_new(""); |
| 4046 | |
| 4047 | context->current_indentation_level++; |
| 4048 | g_string_append(context->string, "struct {\n"); |
| 4049 | |
| 4050 | for (i = 0; i < structure->fields->len; i++) { |
| 4051 | struct structure_field *field = structure->fields->pdata[i]; |
| 4052 | |
| 4053 | BT_LOGD("Serializing structure field type's field metadata: " |
| 4054 | "index=%zu, " |
| 4055 | "field-ft-addr=%p, field-name=\"%s\"", |
| 4056 | i, field, g_quark_to_string(field->name)); |
| 4057 | |
| 4058 | for (indent = 0; indent < context->current_indentation_level; |
| 4059 | indent++) { |
| 4060 | g_string_append_c(context->string, '\t'); |
| 4061 | } |
| 4062 | |
| 4063 | g_string_assign(context->field_name, |
| 4064 | g_quark_to_string(field->name)); |
| 4065 | ret = bt_field_type_serialize(field->type, context); |
| 4066 | if (ret) { |
| 4067 | BT_LOGW("Cannot serialize structure field type's field's metadata: " |
| 4068 | "index=%zu, " |
| 4069 | "field-ft-addr=%p, field-name=\"%s\"", |
| 4070 | i, field->type, |
| 4071 | g_quark_to_string(field->name)); |
| 4072 | goto end; |
| 4073 | } |
| 4074 | |
| 4075 | if (context->field_name->len) { |
| 4076 | append_field_name(context, |
| 4077 | context->field_name->str); |
| 4078 | } |
| 4079 | g_string_append(context->string, ";\n"); |
| 4080 | } |
| 4081 | |
| 4082 | context->current_indentation_level--; |
| 4083 | for (indent = 0; indent < context->current_indentation_level; |
| 4084 | indent++) { |
| 4085 | g_string_append_c(context->string, '\t'); |
| 4086 | } |
| 4087 | |
| 4088 | g_string_append_printf(context->string, "} align(%u)", |
| 4089 | type->alignment); |
| 4090 | end: |
| 4091 | g_string_free(context->field_name, TRUE); |
| 4092 | context->field_name = structure_field_name; |
| 4093 | return ret; |
| 4094 | } |
| 4095 | |
| 4096 | static |
| 4097 | int bt_field_type_variant_serialize(struct bt_field_type *type, |
| 4098 | struct metadata_context *context) |
| 4099 | { |
| 4100 | size_t i; |
| 4101 | unsigned int indent; |
| 4102 | int ret = 0; |
| 4103 | struct bt_field_type_variant *variant = container_of( |
| 4104 | type, struct bt_field_type_variant, parent); |
| 4105 | GString *variant_field_name = context->field_name; |
| 4106 | |
| 4107 | BT_LOGD("Serializing variant field type's metadata: " |
| 4108 | "ft-addr=%p, metadata-context-addr=%p", type, context); |
| 4109 | context->field_name = g_string_new(""); |
| 4110 | if (variant->tag_name->len > 0) { |
| 4111 | g_string_append(context->string, "variant <"); |
| 4112 | append_field_name(context, variant->tag_name->str); |
| 4113 | g_string_append(context->string, "> {\n"); |
| 4114 | } else { |
| 4115 | g_string_append(context->string, "variant {\n"); |
| 4116 | } |
| 4117 | |
| 4118 | context->current_indentation_level++; |
| 4119 | for (i = 0; i < variant->fields->len; i++) { |
| 4120 | struct structure_field *field = variant->fields->pdata[i]; |
| 4121 | |
| 4122 | BT_LOGD("Serializing variant field type's field metadata: " |
| 4123 | "index=%zu, " |
| 4124 | "field-ft-addr=%p, field-name=\"%s\"", |
| 4125 | i, field, g_quark_to_string(field->name)); |
| 4126 | |
| 4127 | g_string_assign(context->field_name, |
| 4128 | g_quark_to_string(field->name)); |
| 4129 | for (indent = 0; indent < context->current_indentation_level; |
| 4130 | indent++) { |
| 4131 | g_string_append_c(context->string, '\t'); |
| 4132 | } |
| 4133 | |
| 4134 | g_string_assign(context->field_name, |
| 4135 | g_quark_to_string(field->name)); |
| 4136 | ret = bt_field_type_serialize(field->type, context); |
| 4137 | if (ret) { |
| 4138 | BT_LOGW("Cannot serialize variant field type's field's metadata: " |
| 4139 | "index=%zu, " |
| 4140 | "field-ft-addr=%p, field-name=\"%s\"", |
| 4141 | i, field->type, |
| 4142 | g_quark_to_string(field->name)); |
| 4143 | goto end; |
| 4144 | } |
| 4145 | |
| 4146 | if (context->field_name->len) { |
| 4147 | append_field_name(context, |
| 4148 | context->field_name->str); |
| 4149 | g_string_append_c(context->string, ';'); |
| 4150 | } |
| 4151 | |
| 4152 | g_string_append_c(context->string, '\n'); |
| 4153 | } |
| 4154 | |
| 4155 | context->current_indentation_level--; |
| 4156 | for (indent = 0; indent < context->current_indentation_level; |
| 4157 | indent++) { |
| 4158 | g_string_append_c(context->string, '\t'); |
| 4159 | } |
| 4160 | |
| 4161 | g_string_append(context->string, "}"); |
| 4162 | end: |
| 4163 | g_string_free(context->field_name, TRUE); |
| 4164 | context->field_name = variant_field_name; |
| 4165 | return ret; |
| 4166 | } |
| 4167 | |
| 4168 | static |
| 4169 | int bt_field_type_array_serialize(struct bt_field_type *type, |
| 4170 | struct metadata_context *context) |
| 4171 | { |
| 4172 | int ret = 0; |
| 4173 | struct bt_field_type_array *array = container_of(type, |
| 4174 | struct bt_field_type_array, parent); |
| 4175 | |
| 4176 | BT_LOGD("Serializing array field type's metadata: " |
| 4177 | "ft-addr=%p, metadata-context-addr=%p", type, context); |
| 4178 | BT_LOGD_STR("Serializing array field type's element field type's metadata."); |
| 4179 | ret = bt_field_type_serialize(array->element_type, context); |
| 4180 | if (ret) { |
| 4181 | BT_LOGW("Cannot serialize array field type's element field type's metadata: " |
| 4182 | "element-ft-addr=%p", array->element_type); |
| 4183 | goto end; |
| 4184 | } |
| 4185 | |
| 4186 | if (context->field_name->len) { |
| 4187 | append_field_name(context, |
| 4188 | context->field_name->str); |
| 4189 | |
| 4190 | g_string_append_printf(context->string, "[%u]", array->length); |
| 4191 | g_string_assign(context->field_name, ""); |
| 4192 | } else { |
| 4193 | g_string_append_printf(context->string, "[%u]", array->length); |
| 4194 | } |
| 4195 | end: |
| 4196 | return ret; |
| 4197 | } |
| 4198 | |
| 4199 | static |
| 4200 | int bt_field_type_sequence_serialize(struct bt_field_type *type, |
| 4201 | struct metadata_context *context) |
| 4202 | { |
| 4203 | int ret = 0; |
| 4204 | struct bt_field_type_sequence *sequence = container_of( |
| 4205 | type, struct bt_field_type_sequence, parent); |
| 4206 | |
| 4207 | BT_LOGD("Serializing sequence field type's metadata: " |
| 4208 | "ft-addr=%p, metadata-context-addr=%p", type, context); |
| 4209 | BT_LOGD_STR("Serializing sequence field type's element field type's metadata."); |
| 4210 | ret = bt_field_type_serialize(sequence->element_type, context); |
| 4211 | if (ret) { |
| 4212 | BT_LOGW("Cannot serialize sequence field type's element field type's metadata: " |
| 4213 | "element-ft-addr=%p", sequence->element_type); |
| 4214 | goto end; |
| 4215 | } |
| 4216 | |
| 4217 | if (context->field_name->len) { |
| 4218 | append_field_name(context, context->field_name->str); |
| 4219 | g_string_assign(context->field_name, ""); |
| 4220 | } |
| 4221 | g_string_append(context->string, "["); |
| 4222 | append_field_name(context, sequence->length_field_name->str); |
| 4223 | g_string_append(context->string, "]"); |
| 4224 | end: |
| 4225 | return ret; |
| 4226 | } |
| 4227 | |
| 4228 | static |
| 4229 | int bt_field_type_string_serialize(struct bt_field_type *type, |
| 4230 | struct metadata_context *context) |
| 4231 | { |
| 4232 | struct bt_field_type_string *string = container_of( |
| 4233 | type, struct bt_field_type_string, parent); |
| 4234 | |
| 4235 | BT_LOGD("Serializing string field type's metadata: " |
| 4236 | "ft-addr=%p, metadata-context-addr=%p", type, context); |
| 4237 | g_string_append_printf(context->string, |
| 4238 | "string { encoding = %s; }", |
| 4239 | get_encoding_string(string->encoding)); |
| 4240 | return 0; |
| 4241 | } |
| 4242 | |
| 4243 | static |
| 4244 | void bt_field_type_integer_set_byte_order(struct bt_field_type *type, |
| 4245 | enum bt_byte_order byte_order) |
| 4246 | { |
| 4247 | struct bt_field_type_integer *integer_type = container_of(type, |
| 4248 | struct bt_field_type_integer, parent); |
| 4249 | |
| 4250 | integer_type->user_byte_order = byte_order; |
| 4251 | } |
| 4252 | |
| 4253 | static |
| 4254 | void bt_field_type_enumeration_set_byte_order( |
| 4255 | struct bt_field_type *type, enum bt_byte_order byte_order) |
| 4256 | { |
| 4257 | struct bt_field_type_enumeration *enum_type = container_of(type, |
| 4258 | struct bt_field_type_enumeration, parent); |
| 4259 | |
| 4260 | /* Safe to assume that container is an integer */ |
| 4261 | bt_field_type_integer_set_byte_order(enum_type->container, |
| 4262 | byte_order); |
| 4263 | } |
| 4264 | |
| 4265 | static |
| 4266 | void bt_field_type_floating_point_set_byte_order( |
| 4267 | struct bt_field_type *type, enum bt_byte_order byte_order) |
| 4268 | { |
| 4269 | struct bt_field_type_floating_point *floating_point_type = |
| 4270 | container_of(type, struct bt_field_type_floating_point, |
| 4271 | parent); |
| 4272 | |
| 4273 | floating_point_type->user_byte_order = byte_order; |
| 4274 | } |
| 4275 | |
| 4276 | static |
| 4277 | void bt_field_type_structure_set_byte_order(struct bt_field_type *type, |
| 4278 | enum bt_byte_order byte_order) |
| 4279 | { |
| 4280 | int i; |
| 4281 | struct bt_field_type_structure *structure_type = |
| 4282 | container_of(type, struct bt_field_type_structure, |
| 4283 | parent); |
| 4284 | |
| 4285 | for (i = 0; i < structure_type->fields->len; i++) { |
| 4286 | struct structure_field *field = g_ptr_array_index( |
| 4287 | structure_type->fields, i); |
| 4288 | struct bt_field_type *field_type = field->type; |
| 4289 | |
| 4290 | if (set_byte_order_funcs[field_type->id]) { |
| 4291 | set_byte_order_funcs[field_type->id]( |
| 4292 | field_type, byte_order); |
| 4293 | } |
| 4294 | } |
| 4295 | } |
| 4296 | |
| 4297 | static |
| 4298 | void bt_field_type_variant_set_byte_order(struct bt_field_type *type, |
| 4299 | enum bt_byte_order byte_order) |
| 4300 | { |
| 4301 | int i; |
| 4302 | struct bt_field_type_variant *variant_type = |
| 4303 | container_of(type, struct bt_field_type_variant, |
| 4304 | parent); |
| 4305 | |
| 4306 | for (i = 0; i < variant_type->fields->len; i++) { |
| 4307 | struct structure_field *field = g_ptr_array_index( |
| 4308 | variant_type->fields, i); |
| 4309 | struct bt_field_type *field_type = field->type; |
| 4310 | |
| 4311 | if (set_byte_order_funcs[field_type->id]) { |
| 4312 | set_byte_order_funcs[field_type->id]( |
| 4313 | field_type, byte_order); |
| 4314 | } |
| 4315 | } |
| 4316 | } |
| 4317 | |
| 4318 | static |
| 4319 | void bt_field_type_array_set_byte_order(struct bt_field_type *type, |
| 4320 | enum bt_byte_order byte_order) |
| 4321 | { |
| 4322 | struct bt_field_type_array *array_type = |
| 4323 | container_of(type, struct bt_field_type_array, |
| 4324 | parent); |
| 4325 | |
| 4326 | if (set_byte_order_funcs[array_type->element_type->id]) { |
| 4327 | set_byte_order_funcs[array_type->element_type->id]( |
| 4328 | array_type->element_type, byte_order); |
| 4329 | } |
| 4330 | } |
| 4331 | |
| 4332 | static |
| 4333 | void bt_field_type_sequence_set_byte_order(struct bt_field_type *type, |
| 4334 | enum bt_byte_order byte_order) |
| 4335 | { |
| 4336 | struct bt_field_type_sequence *sequence_type = |
| 4337 | container_of(type, struct bt_field_type_sequence, |
| 4338 | parent); |
| 4339 | |
| 4340 | if (set_byte_order_funcs[ |
| 4341 | sequence_type->element_type->id]) { |
| 4342 | set_byte_order_funcs[ |
| 4343 | sequence_type->element_type->id]( |
| 4344 | sequence_type->element_type, byte_order); |
| 4345 | } |
| 4346 | } |
| 4347 | |
| 4348 | static |
| 4349 | struct bt_field_type *bt_field_type_integer_copy( |
| 4350 | struct bt_field_type *type) |
| 4351 | { |
| 4352 | struct bt_field_type *copy; |
| 4353 | struct bt_field_type_integer *integer, *copy_integer; |
| 4354 | |
| 4355 | BT_LOGD("Copying integer field type's: addr=%p", type); |
| 4356 | integer = container_of(type, struct bt_field_type_integer, parent); |
| 4357 | copy = bt_field_type_integer_create(integer->size); |
| 4358 | if (!copy) { |
| 4359 | BT_LOGE_STR("Cannot create integer field type."); |
| 4360 | goto end; |
| 4361 | } |
| 4362 | |
| 4363 | copy_integer = container_of(copy, struct bt_field_type_integer, |
| 4364 | parent); |
| 4365 | copy_integer->mapped_clock = bt_get(integer->mapped_clock); |
| 4366 | copy_integer->user_byte_order = integer->user_byte_order; |
| 4367 | copy_integer->is_signed = integer->is_signed; |
| 4368 | copy_integer->size = integer->size; |
| 4369 | copy_integer->base = integer->base; |
| 4370 | copy_integer->encoding = integer->encoding; |
| 4371 | BT_LOGD("Copied integer field type: original-ft-addr=%p, copy-ft-addr=%p", |
| 4372 | type, copy); |
| 4373 | |
| 4374 | end: |
| 4375 | return copy; |
| 4376 | } |
| 4377 | |
| 4378 | static |
| 4379 | struct bt_field_type *bt_field_type_enumeration_copy( |
| 4380 | struct bt_field_type *type) |
| 4381 | { |
| 4382 | size_t i; |
| 4383 | struct bt_field_type *copy = NULL, *copy_container; |
| 4384 | struct bt_field_type_enumeration *enumeration, *copy_enumeration; |
| 4385 | |
| 4386 | BT_LOGD("Copying enumeration field type's: addr=%p", type); |
| 4387 | enumeration = container_of(type, struct bt_field_type_enumeration, |
| 4388 | parent); |
| 4389 | |
| 4390 | /* Copy the source enumeration's container */ |
| 4391 | BT_LOGD_STR("Copying enumeration field type's container field type."); |
| 4392 | copy_container = bt_field_type_copy(enumeration->container); |
| 4393 | if (!copy_container) { |
| 4394 | BT_LOGE_STR("Cannot copy enumeration field type's container field type."); |
| 4395 | goto end; |
| 4396 | } |
| 4397 | |
| 4398 | copy = bt_field_type_enumeration_create(copy_container); |
| 4399 | if (!copy) { |
| 4400 | BT_LOGE_STR("Cannot create enumeration field type."); |
| 4401 | goto end; |
| 4402 | } |
| 4403 | copy_enumeration = container_of(copy, |
| 4404 | struct bt_field_type_enumeration, parent); |
| 4405 | |
| 4406 | /* Copy all enumaration entries */ |
| 4407 | for (i = 0; i < enumeration->entries->len; i++) { |
| 4408 | struct enumeration_mapping *mapping = g_ptr_array_index( |
| 4409 | enumeration->entries, i); |
| 4410 | struct enumeration_mapping *copy_mapping = g_new0( |
| 4411 | struct enumeration_mapping, 1); |
| 4412 | |
| 4413 | if (!copy_mapping) { |
| 4414 | BT_LOGE_STR("Failed to allocate one enumeration mapping."); |
| 4415 | goto error; |
| 4416 | } |
| 4417 | |
| 4418 | *copy_mapping = *mapping; |
| 4419 | g_ptr_array_add(copy_enumeration->entries, copy_mapping); |
| 4420 | } |
| 4421 | |
| 4422 | BT_LOGD("Copied enumeration field type: original-ft-addr=%p, copy-ft-addr=%p", |
| 4423 | type, copy); |
| 4424 | |
| 4425 | end: |
| 4426 | bt_put(copy_container); |
| 4427 | return copy; |
| 4428 | error: |
| 4429 | bt_put(copy_container); |
| 4430 | BT_PUT(copy); |
| 4431 | return copy; |
| 4432 | } |
| 4433 | |
| 4434 | static |
| 4435 | struct bt_field_type *bt_field_type_floating_point_copy( |
| 4436 | struct bt_field_type *type) |
| 4437 | { |
| 4438 | struct bt_field_type *copy; |
| 4439 | struct bt_field_type_floating_point *floating_point, *copy_float; |
| 4440 | |
| 4441 | BT_LOGD("Copying floating point number field type's: addr=%p", type); |
| 4442 | floating_point = container_of(type, |
| 4443 | struct bt_field_type_floating_point, parent); |
| 4444 | copy = bt_field_type_floating_point_create(); |
| 4445 | if (!copy) { |
| 4446 | BT_LOGE_STR("Cannot create floating point number field type."); |
| 4447 | goto end; |
| 4448 | } |
| 4449 | |
| 4450 | copy_float = container_of(copy, |
| 4451 | struct bt_field_type_floating_point, parent); |
| 4452 | copy_float->user_byte_order = floating_point->user_byte_order; |
| 4453 | copy_float->exp_dig = floating_point->exp_dig; |
| 4454 | copy_float->mant_dig = floating_point->mant_dig; |
| 4455 | BT_LOGD("Copied floating point number field type: original-ft-addr=%p, copy-ft-addr=%p", |
| 4456 | type, copy); |
| 4457 | end: |
| 4458 | return copy; |
| 4459 | } |
| 4460 | |
| 4461 | static |
| 4462 | struct bt_field_type *bt_field_type_structure_copy( |
| 4463 | struct bt_field_type *type) |
| 4464 | { |
| 4465 | int64_t i; |
| 4466 | GHashTableIter iter; |
| 4467 | gpointer key, value; |
| 4468 | struct bt_field_type *copy; |
| 4469 | struct bt_field_type_structure *structure, *copy_structure; |
| 4470 | |
| 4471 | BT_LOGD("Copying structure field type's: addr=%p", type); |
| 4472 | structure = container_of(type, struct bt_field_type_structure, |
| 4473 | parent); |
| 4474 | copy = bt_field_type_structure_create(); |
| 4475 | if (!copy) { |
| 4476 | BT_LOGE_STR("Cannot create structure field type."); |
| 4477 | goto end; |
| 4478 | } |
| 4479 | |
| 4480 | copy_structure = container_of(copy, |
| 4481 | struct bt_field_type_structure, parent); |
| 4482 | |
| 4483 | /* Copy field_name_to_index */ |
| 4484 | g_hash_table_iter_init(&iter, structure->field_name_to_index); |
| 4485 | while (g_hash_table_iter_next (&iter, &key, &value)) { |
| 4486 | g_hash_table_insert(copy_structure->field_name_to_index, |
| 4487 | key, value); |
| 4488 | } |
| 4489 | |
| 4490 | for (i = 0; i < structure->fields->len; i++) { |
| 4491 | struct structure_field *entry, *copy_entry; |
| 4492 | struct bt_field_type *copy_field; |
| 4493 | |
| 4494 | entry = g_ptr_array_index(structure->fields, i); |
| 4495 | BT_LOGD("Copying structure field type's field: " |
| 4496 | "index=%" PRId64 ", " |
| 4497 | "field-ft-addr=%p, field-name=\"%s\"", |
| 4498 | i, entry, g_quark_to_string(entry->name)); |
| 4499 | copy_entry = g_new0(struct structure_field, 1); |
| 4500 | if (!copy_entry) { |
| 4501 | BT_LOGE_STR("Failed to allocate one structure field type field."); |
| 4502 | goto error; |
| 4503 | } |
| 4504 | |
| 4505 | copy_field = bt_field_type_copy(entry->type); |
| 4506 | if (!copy_field) { |
| 4507 | BT_LOGE("Cannot copy structure field type's field: " |
| 4508 | "index=%" PRId64 ", " |
| 4509 | "field-ft-addr=%p, field-name=\"%s\"", |
| 4510 | i, entry, g_quark_to_string(entry->name)); |
| 4511 | g_free(copy_entry); |
| 4512 | goto error; |
| 4513 | } |
| 4514 | |
| 4515 | copy_entry->name = entry->name; |
| 4516 | copy_entry->type = copy_field; |
| 4517 | g_ptr_array_add(copy_structure->fields, copy_entry); |
| 4518 | } |
| 4519 | |
| 4520 | BT_LOGD("Copied structure field type: original-ft-addr=%p, copy-ft-addr=%p", |
| 4521 | type, copy); |
| 4522 | |
| 4523 | end: |
| 4524 | return copy; |
| 4525 | error: |
| 4526 | BT_PUT(copy); |
| 4527 | return copy; |
| 4528 | } |
| 4529 | |
| 4530 | static |
| 4531 | struct bt_field_type *bt_field_type_variant_copy( |
| 4532 | struct bt_field_type *type) |
| 4533 | { |
| 4534 | int64_t i; |
| 4535 | GHashTableIter iter; |
| 4536 | gpointer key, value; |
| 4537 | struct bt_field_type *copy = NULL, *copy_tag = NULL; |
| 4538 | struct bt_field_type_variant *variant, *copy_variant; |
| 4539 | |
| 4540 | BT_LOGD("Copying variant field type's: addr=%p", type); |
| 4541 | variant = container_of(type, struct bt_field_type_variant, |
| 4542 | parent); |
| 4543 | if (variant->tag) { |
| 4544 | BT_LOGD_STR("Copying variant field type's tag field type."); |
| 4545 | copy_tag = bt_field_type_copy(&variant->tag->parent); |
| 4546 | if (!copy_tag) { |
| 4547 | BT_LOGE_STR("Cannot copy variant field type's tag field type."); |
| 4548 | goto end; |
| 4549 | } |
| 4550 | } |
| 4551 | |
| 4552 | copy = bt_field_type_variant_create(copy_tag, |
| 4553 | variant->tag_name->len ? variant->tag_name->str : NULL); |
| 4554 | if (!copy) { |
| 4555 | BT_LOGE_STR("Cannot create variant field type."); |
| 4556 | goto end; |
| 4557 | } |
| 4558 | |
| 4559 | copy_variant = container_of(copy, struct bt_field_type_variant, |
| 4560 | parent); |
| 4561 | |
| 4562 | /* Copy field_name_to_index */ |
| 4563 | g_hash_table_iter_init(&iter, variant->field_name_to_index); |
| 4564 | while (g_hash_table_iter_next (&iter, &key, &value)) { |
| 4565 | g_hash_table_insert(copy_variant->field_name_to_index, |
| 4566 | key, value); |
| 4567 | } |
| 4568 | |
| 4569 | for (i = 0; i < variant->fields->len; i++) { |
| 4570 | struct structure_field *entry, *copy_entry; |
| 4571 | struct bt_field_type *copy_field; |
| 4572 | |
| 4573 | entry = g_ptr_array_index(variant->fields, i); |
| 4574 | BT_LOGD("Copying variant field type's field: " |
| 4575 | "index=%" PRId64 ", " |
| 4576 | "field-ft-addr=%p, field-name=\"%s\"", |
| 4577 | i, entry, g_quark_to_string(entry->name)); |
| 4578 | copy_entry = g_new0(struct structure_field, 1); |
| 4579 | if (!copy_entry) { |
| 4580 | BT_LOGE_STR("Failed to allocate one variant field type field."); |
| 4581 | goto error; |
| 4582 | } |
| 4583 | |
| 4584 | copy_field = bt_field_type_copy(entry->type); |
| 4585 | if (!copy_field) { |
| 4586 | BT_LOGE("Cannot copy variant field type's field: " |
| 4587 | "index=%" PRId64 ", " |
| 4588 | "field-ft-addr=%p, field-name=\"%s\"", |
| 4589 | i, entry, g_quark_to_string(entry->name)); |
| 4590 | g_free(copy_entry); |
| 4591 | goto error; |
| 4592 | } |
| 4593 | |
| 4594 | copy_entry->name = entry->name; |
| 4595 | copy_entry->type = copy_field; |
| 4596 | g_ptr_array_add(copy_variant->fields, copy_entry); |
| 4597 | } |
| 4598 | |
| 4599 | if (variant->tag_field_path) { |
| 4600 | BT_LOGD_STR("Copying variant field type's tag field path."); |
| 4601 | copy_variant->tag_field_path = bt_field_path_copy( |
| 4602 | variant->tag_field_path); |
| 4603 | if (!copy_variant->tag_field_path) { |
| 4604 | BT_LOGE_STR("Cannot copy variant field type's tag field path."); |
| 4605 | goto error; |
| 4606 | } |
| 4607 | } |
| 4608 | |
| 4609 | BT_LOGD("Copied variant field type: original-ft-addr=%p, copy-ft-addr=%p", |
| 4610 | type, copy); |
| 4611 | |
| 4612 | end: |
| 4613 | bt_put(copy_tag); |
| 4614 | return copy; |
| 4615 | error: |
| 4616 | bt_put(copy_tag); |
| 4617 | BT_PUT(copy); |
| 4618 | return copy; |
| 4619 | } |
| 4620 | |
| 4621 | static |
| 4622 | struct bt_field_type *bt_field_type_array_copy( |
| 4623 | struct bt_field_type *type) |
| 4624 | { |
| 4625 | struct bt_field_type *copy = NULL, *copy_element; |
| 4626 | struct bt_field_type_array *array; |
| 4627 | |
| 4628 | BT_LOGD("Copying array field type's: addr=%p", type); |
| 4629 | array = container_of(type, struct bt_field_type_array, |
| 4630 | parent); |
| 4631 | BT_LOGD_STR("Copying array field type's element field type."); |
| 4632 | copy_element = bt_field_type_copy(array->element_type); |
| 4633 | if (!copy_element) { |
| 4634 | BT_LOGE_STR("Cannot copy array field type's element field type."); |
| 4635 | goto end; |
| 4636 | } |
| 4637 | |
| 4638 | copy = bt_field_type_array_create(copy_element, array->length); |
| 4639 | if (!copy) { |
| 4640 | BT_LOGE_STR("Cannot create array field type."); |
| 4641 | goto end; |
| 4642 | } |
| 4643 | |
| 4644 | BT_LOGD("Copied array field type: original-ft-addr=%p, copy-ft-addr=%p", |
| 4645 | type, copy); |
| 4646 | |
| 4647 | end: |
| 4648 | bt_put(copy_element); |
| 4649 | return copy; |
| 4650 | } |
| 4651 | |
| 4652 | static |
| 4653 | struct bt_field_type *bt_field_type_sequence_copy( |
| 4654 | struct bt_field_type *type) |
| 4655 | { |
| 4656 | struct bt_field_type *copy = NULL, *copy_element; |
| 4657 | struct bt_field_type_sequence *sequence, *copy_sequence; |
| 4658 | |
| 4659 | BT_LOGD("Copying sequence field type's: addr=%p", type); |
| 4660 | sequence = container_of(type, struct bt_field_type_sequence, |
| 4661 | parent); |
| 4662 | BT_LOGD_STR("Copying sequence field type's element field type."); |
| 4663 | copy_element = bt_field_type_copy(sequence->element_type); |
| 4664 | if (!copy_element) { |
| 4665 | BT_LOGE_STR("Cannot copy sequence field type's element field type."); |
| 4666 | goto end; |
| 4667 | } |
| 4668 | |
| 4669 | copy = bt_field_type_sequence_create(copy_element, |
| 4670 | sequence->length_field_name->len ? |
| 4671 | sequence->length_field_name->str : NULL); |
| 4672 | if (!copy) { |
| 4673 | BT_LOGE_STR("Cannot create sequence field type."); |
| 4674 | goto end; |
| 4675 | } |
| 4676 | |
| 4677 | copy_sequence = container_of(copy, struct bt_field_type_sequence, |
| 4678 | parent); |
| 4679 | if (sequence->length_field_path) { |
| 4680 | BT_LOGD_STR("Copying sequence field type's length field path."); |
| 4681 | copy_sequence->length_field_path = bt_field_path_copy( |
| 4682 | sequence->length_field_path); |
| 4683 | if (!copy_sequence->length_field_path) { |
| 4684 | BT_LOGE_STR("Cannot copy sequence field type's length field path."); |
| 4685 | goto error; |
| 4686 | } |
| 4687 | } |
| 4688 | |
| 4689 | BT_LOGD("Copied sequence field type: original-ft-addr=%p, copy-ft-addr=%p", |
| 4690 | type, copy); |
| 4691 | |
| 4692 | end: |
| 4693 | bt_put(copy_element); |
| 4694 | return copy; |
| 4695 | error: |
| 4696 | BT_PUT(copy); |
| 4697 | goto end; |
| 4698 | } |
| 4699 | |
| 4700 | static |
| 4701 | struct bt_field_type *bt_field_type_string_copy( |
| 4702 | struct bt_field_type *type) |
| 4703 | { |
| 4704 | struct bt_field_type *copy; |
| 4705 | |
| 4706 | BT_LOGD("Copying string field type's: addr=%p", type); |
| 4707 | copy = bt_field_type_string_create(); |
| 4708 | if (!copy) { |
| 4709 | BT_LOGE_STR("Cannot create string field type."); |
| 4710 | goto end; |
| 4711 | } |
| 4712 | |
| 4713 | BT_LOGD("Copied string field type: original-ft-addr=%p, copy-ft-addr=%p", |
| 4714 | type, copy); |
| 4715 | end: |
| 4716 | return copy; |
| 4717 | } |
| 4718 | |
| 4719 | static |
| 4720 | int bt_field_type_integer_compare(struct bt_field_type *type_a, |
| 4721 | struct bt_field_type *type_b) |
| 4722 | { |
| 4723 | int ret = 1; |
| 4724 | struct bt_field_type_integer *int_type_a; |
| 4725 | struct bt_field_type_integer *int_type_b; |
| 4726 | |
| 4727 | int_type_a = container_of(type_a, struct bt_field_type_integer, |
| 4728 | parent); |
| 4729 | int_type_b = container_of(type_b, struct bt_field_type_integer, |
| 4730 | parent); |
| 4731 | |
| 4732 | /* Length */ |
| 4733 | if (int_type_a->size != int_type_b->size) { |
| 4734 | BT_LOGV("Integer field types differ: different sizes: " |
| 4735 | "ft-a-size=%u, ft-b-size=%u", |
| 4736 | int_type_a->size, int_type_b->size); |
| 4737 | goto end; |
| 4738 | } |
| 4739 | |
| 4740 | /* Byte order */ |
| 4741 | if (int_type_a->user_byte_order != int_type_b->user_byte_order) { |
| 4742 | BT_LOGV("Integer field types differ: different byte orders: " |
| 4743 | "ft-a-bo=%s, ft-b-bo=%s", |
| 4744 | bt_byte_order_string(int_type_a->user_byte_order), |
| 4745 | bt_byte_order_string(int_type_b->user_byte_order)); |
| 4746 | goto end; |
| 4747 | } |
| 4748 | |
| 4749 | /* Signedness */ |
| 4750 | if (int_type_a->is_signed != int_type_b->is_signed) { |
| 4751 | BT_LOGV("Integer field types differ: different signedness: " |
| 4752 | "ft-a-is-signed=%d, ft-b-is-signed=%d", |
| 4753 | int_type_a->is_signed, |
| 4754 | int_type_b->is_signed); |
| 4755 | goto end; |
| 4756 | } |
| 4757 | |
| 4758 | /* Base */ |
| 4759 | if (int_type_a->base != int_type_b->base) { |
| 4760 | BT_LOGV("Integer field types differ: different bases: " |
| 4761 | "ft-a-base=%s, ft-b-base=%s", |
| 4762 | bt_integer_base_string(int_type_a->base), |
| 4763 | bt_integer_base_string(int_type_b->base)); |
| 4764 | goto end; |
| 4765 | } |
| 4766 | |
| 4767 | /* Encoding */ |
| 4768 | if (int_type_a->encoding != int_type_b->encoding) { |
| 4769 | BT_LOGV("Integer field types differ: different encodings: " |
| 4770 | "ft-a-encoding=%s, ft-b-encoding=%s", |
| 4771 | bt_string_encoding_string(int_type_a->encoding), |
| 4772 | bt_string_encoding_string(int_type_b->encoding)); |
| 4773 | goto end; |
| 4774 | } |
| 4775 | |
| 4776 | /* Mapped clock class */ |
| 4777 | if (int_type_a->mapped_clock) { |
| 4778 | if (!int_type_b->mapped_clock) { |
| 4779 | BT_LOGV_STR("Integer field types differ: field type A " |
| 4780 | "has a mapped clock class, but field type B " |
| 4781 | "does not."); |
| 4782 | goto end; |
| 4783 | } |
| 4784 | |
| 4785 | if (bt_clock_class_compare(int_type_a->mapped_clock, |
| 4786 | int_type_b->mapped_clock) != 0) { |
| 4787 | BT_LOGV_STR("Integer field types differ: different " |
| 4788 | "mapped clock classes."); |
| 4789 | } |
| 4790 | } else { |
| 4791 | if (int_type_b->mapped_clock) { |
| 4792 | BT_LOGV_STR("Integer field types differ: field type A " |
| 4793 | "has no description, but field type B has one."); |
| 4794 | goto end; |
| 4795 | } |
| 4796 | } |
| 4797 | |
| 4798 | /* Equal */ |
| 4799 | ret = 0; |
| 4800 | |
| 4801 | end: |
| 4802 | return ret; |
| 4803 | } |
| 4804 | |
| 4805 | static |
| 4806 | int bt_field_type_floating_point_compare(struct bt_field_type *type_a, |
| 4807 | struct bt_field_type *type_b) |
| 4808 | { |
| 4809 | int ret = 1; |
| 4810 | struct bt_field_type_floating_point *float_a; |
| 4811 | struct bt_field_type_floating_point *float_b; |
| 4812 | |
| 4813 | float_a = container_of(type_a, |
| 4814 | struct bt_field_type_floating_point, parent); |
| 4815 | float_b = container_of(type_b, |
| 4816 | struct bt_field_type_floating_point, parent); |
| 4817 | |
| 4818 | /* Byte order */ |
| 4819 | if (float_a->user_byte_order != float_b->user_byte_order) { |
| 4820 | BT_LOGV("Floating point number field types differ: different byte orders: " |
| 4821 | "ft-a-bo=%s, ft-b-bo=%s", |
| 4822 | bt_byte_order_string(float_a->user_byte_order), |
| 4823 | bt_byte_order_string(float_b->user_byte_order)); |
| 4824 | goto end; |
| 4825 | } |
| 4826 | |
| 4827 | /* Exponent length */ |
| 4828 | if (float_a->exp_dig != float_b->exp_dig) { |
| 4829 | BT_LOGV("Floating point number field types differ: different exponent sizes: " |
| 4830 | "ft-a-exp-size=%u, ft-b-exp-size=%u", |
| 4831 | float_a->exp_dig, float_b->exp_dig); |
| 4832 | goto end; |
| 4833 | } |
| 4834 | |
| 4835 | /* Mantissa length */ |
| 4836 | if (float_a->mant_dig != float_b->mant_dig) { |
| 4837 | BT_LOGV("Floating point number field types differ: different mantissa sizes: " |
| 4838 | "ft-a-mant-size=%u, ft-b-mant-size=%u", |
| 4839 | float_a->mant_dig, float_b->mant_dig); |
| 4840 | goto end; |
| 4841 | } |
| 4842 | |
| 4843 | /* Equal */ |
| 4844 | ret = 0; |
| 4845 | |
| 4846 | end: |
| 4847 | return ret; |
| 4848 | } |
| 4849 | |
| 4850 | static |
| 4851 | int compare_enumeration_mappings(struct enumeration_mapping *mapping_a, |
| 4852 | struct enumeration_mapping *mapping_b) |
| 4853 | { |
| 4854 | int ret = 1; |
| 4855 | |
| 4856 | /* Label */ |
| 4857 | if (mapping_a->string != mapping_b->string) { |
| 4858 | BT_LOGV("Enumeration field type mappings differ: different names: " |
| 4859 | "mapping-a-name=\"%s\", mapping-b-name=\"%s\"", |
| 4860 | g_quark_to_string(mapping_a->string), |
| 4861 | g_quark_to_string(mapping_b->string)); |
| 4862 | goto end; |
| 4863 | } |
| 4864 | |
| 4865 | /* Range start */ |
| 4866 | if (mapping_a->range_start._unsigned != |
| 4867 | mapping_b->range_start._unsigned) { |
| 4868 | BT_LOGV("Enumeration field type mappings differ: different starts of range: " |
| 4869 | "mapping-a-range-start-unsigned=%" PRIu64 ", " |
| 4870 | "mapping-b-range-start-unsigned=%" PRIu64, |
| 4871 | mapping_a->range_start._unsigned, |
| 4872 | mapping_b->range_start._unsigned); |
| 4873 | goto end; |
| 4874 | } |
| 4875 | |
| 4876 | /* Range end */ |
| 4877 | if (mapping_a->range_end._unsigned != |
| 4878 | mapping_b->range_end._unsigned) { |
| 4879 | BT_LOGV("Enumeration field type mappings differ: different ends of range: " |
| 4880 | "mapping-a-range-end-unsigned=%" PRIu64 ", " |
| 4881 | "mapping-b-range-end-unsigned=%" PRIu64, |
| 4882 | mapping_a->range_end._unsigned, |
| 4883 | mapping_b->range_end._unsigned); |
| 4884 | goto end; |
| 4885 | } |
| 4886 | |
| 4887 | /* Equal */ |
| 4888 | ret = 0; |
| 4889 | |
| 4890 | end: |
| 4891 | return ret; |
| 4892 | } |
| 4893 | |
| 4894 | static |
| 4895 | int bt_field_type_enumeration_compare(struct bt_field_type *type_a, |
| 4896 | struct bt_field_type *type_b) |
| 4897 | { |
| 4898 | int ret = 1; |
| 4899 | int i; |
| 4900 | struct bt_field_type_enumeration *enum_a; |
| 4901 | struct bt_field_type_enumeration *enum_b; |
| 4902 | |
| 4903 | enum_a = container_of(type_a, |
| 4904 | struct bt_field_type_enumeration, parent); |
| 4905 | enum_b = container_of(type_b, |
| 4906 | struct bt_field_type_enumeration, parent); |
| 4907 | |
| 4908 | /* Container field type */ |
| 4909 | ret = bt_field_type_compare(enum_a->container, enum_b->container); |
| 4910 | if (ret) { |
| 4911 | BT_LOGV("Enumeration field types differ: different container field types: " |
| 4912 | "ft-a-container-ft-addr=%p, ft-b-container-ft-addr=%p", |
| 4913 | enum_a->container, enum_b->container); |
| 4914 | goto end; |
| 4915 | } |
| 4916 | |
| 4917 | ret = 1; |
| 4918 | |
| 4919 | /* Entries */ |
| 4920 | if (enum_a->entries->len != enum_b->entries->len) { |
| 4921 | goto end; |
| 4922 | } |
| 4923 | |
| 4924 | for (i = 0; i < enum_a->entries->len; ++i) { |
| 4925 | struct enumeration_mapping *mapping_a = |
| 4926 | g_ptr_array_index(enum_a->entries, i); |
| 4927 | struct enumeration_mapping *mapping_b = |
| 4928 | g_ptr_array_index(enum_b->entries, i); |
| 4929 | |
| 4930 | if (compare_enumeration_mappings(mapping_a, mapping_b)) { |
| 4931 | BT_LOGV("Enumeration field types differ: different mappings: " |
| 4932 | "ft-a-mapping-addr=%p, ft-b-mapping-addr=%p, " |
| 4933 | "ft-a-mapping-name=\"%s\", ft-b-mapping-name=\"%s\"", |
| 4934 | mapping_a, mapping_b, |
| 4935 | g_quark_to_string(mapping_a->string), |
| 4936 | g_quark_to_string(mapping_b->string)); |
| 4937 | goto end; |
| 4938 | } |
| 4939 | } |
| 4940 | |
| 4941 | /* Equal */ |
| 4942 | ret = 0; |
| 4943 | |
| 4944 | end: |
| 4945 | return ret; |
| 4946 | } |
| 4947 | |
| 4948 | static |
| 4949 | int bt_field_type_string_compare(struct bt_field_type *type_a, |
| 4950 | struct bt_field_type *type_b) |
| 4951 | { |
| 4952 | int ret = 1; |
| 4953 | struct bt_field_type_string *string_a; |
| 4954 | struct bt_field_type_string *string_b; |
| 4955 | |
| 4956 | string_a = container_of(type_a, |
| 4957 | struct bt_field_type_string, parent); |
| 4958 | string_b = container_of(type_b, |
| 4959 | struct bt_field_type_string, parent); |
| 4960 | |
| 4961 | /* Encoding */ |
| 4962 | if (string_a->encoding != string_b->encoding) { |
| 4963 | BT_LOGV("String field types differ: different encodings: " |
| 4964 | "ft-a-encoding=%s, ft-b-encoding=%s", |
| 4965 | bt_string_encoding_string(string_a->encoding), |
| 4966 | bt_string_encoding_string(string_b->encoding)); |
| 4967 | goto end; |
| 4968 | } |
| 4969 | |
| 4970 | /* Equal */ |
| 4971 | ret = 0; |
| 4972 | |
| 4973 | end: |
| 4974 | return ret; |
| 4975 | } |
| 4976 | |
| 4977 | static |
| 4978 | int compare_structure_fields(struct structure_field *field_a, |
| 4979 | struct structure_field *field_b) |
| 4980 | { |
| 4981 | int ret = 1; |
| 4982 | |
| 4983 | /* Label */ |
| 4984 | if (field_a->name != field_b->name) { |
| 4985 | BT_LOGV("Structure/variant field type fields differ: different names: " |
| 4986 | "field-a-name=%s, field-b-name=%s", |
| 4987 | g_quark_to_string(field_a->name), |
| 4988 | g_quark_to_string(field_b->name)); |
| 4989 | goto end; |
| 4990 | } |
| 4991 | |
| 4992 | /* Type */ |
| 4993 | ret = bt_field_type_compare(field_a->type, field_b->type); |
| 4994 | if (ret == 1) { |
| 4995 | BT_LOGV("Structure/variant field type fields differ: different field types: " |
| 4996 | "field-name=\"%s\", field-a-ft-addr=%p, field-b-ft-addr=%p", |
| 4997 | g_quark_to_string(field_a->name), |
| 4998 | field_a->type, field_b->type); |
| 4999 | } |
| 5000 | |
| 5001 | end: |
| 5002 | return ret; |
| 5003 | } |
| 5004 | |
| 5005 | static |
| 5006 | int bt_field_type_structure_compare(struct bt_field_type *type_a, |
| 5007 | struct bt_field_type *type_b) |
| 5008 | { |
| 5009 | int ret = 1; |
| 5010 | int i; |
| 5011 | struct bt_field_type_structure *struct_a; |
| 5012 | struct bt_field_type_structure *struct_b; |
| 5013 | |
| 5014 | struct_a = container_of(type_a, |
| 5015 | struct bt_field_type_structure, parent); |
| 5016 | struct_b = container_of(type_b, |
| 5017 | struct bt_field_type_structure, parent); |
| 5018 | |
| 5019 | /* Alignment */ |
| 5020 | if (bt_field_type_get_alignment(type_a) != |
| 5021 | bt_field_type_get_alignment(type_b)) { |
| 5022 | BT_LOGV("Structure field types differ: different alignments: " |
| 5023 | "ft-a-align=%u, ft-b-align=%u", |
| 5024 | bt_field_type_get_alignment(type_a), |
| 5025 | bt_field_type_get_alignment(type_b)); |
| 5026 | goto end; |
| 5027 | } |
| 5028 | |
| 5029 | /* Fields */ |
| 5030 | if (struct_a->fields->len != struct_b->fields->len) { |
| 5031 | BT_LOGV("Structure field types differ: different field counts: " |
| 5032 | "ft-a-field-count=%u, ft-b-field-count=%u", |
| 5033 | struct_a->fields->len, struct_b->fields->len); |
| 5034 | goto end; |
| 5035 | } |
| 5036 | |
| 5037 | for (i = 0; i < struct_a->fields->len; ++i) { |
| 5038 | struct structure_field *field_a = |
| 5039 | g_ptr_array_index(struct_a->fields, i); |
| 5040 | struct structure_field *field_b = |
| 5041 | g_ptr_array_index(struct_b->fields, i); |
| 5042 | |
| 5043 | ret = compare_structure_fields(field_a, field_b); |
| 5044 | if (ret) { |
| 5045 | /* compare_structure_fields() logs what differs */ |
| 5046 | BT_LOGV_STR("Structure field types differ: different fields."); |
| 5047 | goto end; |
| 5048 | } |
| 5049 | } |
| 5050 | |
| 5051 | /* Equal */ |
| 5052 | ret = 0; |
| 5053 | |
| 5054 | end: |
| 5055 | return ret; |
| 5056 | } |
| 5057 | |
| 5058 | static |
| 5059 | int bt_field_type_variant_compare(struct bt_field_type *type_a, |
| 5060 | struct bt_field_type *type_b) |
| 5061 | { |
| 5062 | int ret = 1; |
| 5063 | int i; |
| 5064 | struct bt_field_type_variant *variant_a; |
| 5065 | struct bt_field_type_variant *variant_b; |
| 5066 | |
| 5067 | variant_a = container_of(type_a, |
| 5068 | struct bt_field_type_variant, parent); |
| 5069 | variant_b = container_of(type_b, |
| 5070 | struct bt_field_type_variant, parent); |
| 5071 | |
| 5072 | /* Tag name */ |
| 5073 | if (strcmp(variant_a->tag_name->str, variant_b->tag_name->str)) { |
| 5074 | BT_LOGV("Variant field types differ: different tag field names: " |
| 5075 | "ft-a-tag-field-name=\"%s\", ft-b-tag-field-name=\"%s\"", |
| 5076 | variant_a->tag_name->str, variant_b->tag_name->str); |
| 5077 | goto end; |
| 5078 | } |
| 5079 | |
| 5080 | /* Tag type */ |
| 5081 | ret = bt_field_type_compare( |
| 5082 | (struct bt_field_type *) variant_a->tag, |
| 5083 | (struct bt_field_type *) variant_b->tag); |
| 5084 | if (ret) { |
| 5085 | BT_LOGV("Variant field types differ: different tag field types: " |
| 5086 | "ft-a-tag-ft-addr=%p, ft-b-tag-ft-addr=%p", |
| 5087 | variant_a->tag, variant_b->tag); |
| 5088 | goto end; |
| 5089 | } |
| 5090 | |
| 5091 | ret = 1; |
| 5092 | |
| 5093 | /* Fields */ |
| 5094 | if (variant_a->fields->len != variant_b->fields->len) { |
| 5095 | BT_LOGV("Structure field types differ: different field counts: " |
| 5096 | "ft-a-field-count=%u, ft-b-field-count=%u", |
| 5097 | variant_a->fields->len, variant_b->fields->len); |
| 5098 | goto end; |
| 5099 | } |
| 5100 | |
| 5101 | for (i = 0; i < variant_a->fields->len; ++i) { |
| 5102 | struct structure_field *field_a = |
| 5103 | g_ptr_array_index(variant_a->fields, i); |
| 5104 | struct structure_field *field_b = |
| 5105 | g_ptr_array_index(variant_b->fields, i); |
| 5106 | |
| 5107 | ret = compare_structure_fields(field_a, field_b); |
| 5108 | if (ret) { |
| 5109 | /* compare_structure_fields() logs what differs */ |
| 5110 | BT_LOGV_STR("Variant field types differ: different fields."); |
| 5111 | goto end; |
| 5112 | } |
| 5113 | } |
| 5114 | |
| 5115 | /* Equal */ |
| 5116 | ret = 0; |
| 5117 | |
| 5118 | end: |
| 5119 | return ret; |
| 5120 | } |
| 5121 | |
| 5122 | static |
| 5123 | int bt_field_type_array_compare(struct bt_field_type *type_a, |
| 5124 | struct bt_field_type *type_b) |
| 5125 | { |
| 5126 | int ret = 1; |
| 5127 | struct bt_field_type_array *array_a; |
| 5128 | struct bt_field_type_array *array_b; |
| 5129 | |
| 5130 | array_a = container_of(type_a, |
| 5131 | struct bt_field_type_array, parent); |
| 5132 | array_b = container_of(type_b, |
| 5133 | struct bt_field_type_array, parent); |
| 5134 | |
| 5135 | /* Length */ |
| 5136 | if (array_a->length != array_b->length) { |
| 5137 | BT_LOGV("Structure field types differ: different lengths: " |
| 5138 | "ft-a-length=%u, ft-b-length=%u", |
| 5139 | array_a->length, array_b->length); |
| 5140 | goto end; |
| 5141 | } |
| 5142 | |
| 5143 | /* Element type */ |
| 5144 | ret = bt_field_type_compare(array_a->element_type, |
| 5145 | array_b->element_type); |
| 5146 | if (ret == 1) { |
| 5147 | BT_LOGV("Array field types differ: different element field types: " |
| 5148 | "ft-a-element-ft-addr=%p, ft-b-element-ft-addr=%p", |
| 5149 | array_a->element_type, array_b->element_type); |
| 5150 | } |
| 5151 | |
| 5152 | end: |
| 5153 | return ret; |
| 5154 | } |
| 5155 | |
| 5156 | static |
| 5157 | int bt_field_type_sequence_compare(struct bt_field_type *type_a, |
| 5158 | struct bt_field_type *type_b) |
| 5159 | { |
| 5160 | int ret = -1; |
| 5161 | struct bt_field_type_sequence *sequence_a; |
| 5162 | struct bt_field_type_sequence *sequence_b; |
| 5163 | |
| 5164 | sequence_a = container_of(type_a, |
| 5165 | struct bt_field_type_sequence, parent); |
| 5166 | sequence_b = container_of(type_b, |
| 5167 | struct bt_field_type_sequence, parent); |
| 5168 | |
| 5169 | /* Length name */ |
| 5170 | if (strcmp(sequence_a->length_field_name->str, |
| 5171 | sequence_b->length_field_name->str)) { |
| 5172 | BT_LOGV("Sequence field types differ: different length field names: " |
| 5173 | "ft-a-length-field-name=\"%s\", " |
| 5174 | "ft-b-length-field-name=\"%s\"", |
| 5175 | sequence_a->length_field_name->str, |
| 5176 | sequence_b->length_field_name->str); |
| 5177 | goto end; |
| 5178 | } |
| 5179 | |
| 5180 | /* Element type */ |
| 5181 | ret = bt_field_type_compare(sequence_a->element_type, |
| 5182 | sequence_b->element_type); |
| 5183 | if (ret == 1) { |
| 5184 | BT_LOGV("Sequence field types differ: different element field types: " |
| 5185 | "ft-a-element-ft-addr=%p, ft-b-element-ft-addr=%p", |
| 5186 | sequence_a->element_type, sequence_b->element_type); |
| 5187 | } |
| 5188 | |
| 5189 | end: |
| 5190 | return ret; |
| 5191 | } |
| 5192 | |
| 5193 | int bt_field_type_compare(struct bt_field_type *type_a, |
| 5194 | struct bt_field_type *type_b) |
| 5195 | { |
| 5196 | int ret = 1; |
| 5197 | |
| 5198 | if (type_a == type_b) { |
| 5199 | /* Same reference: equal (even if both are NULL) */ |
| 5200 | ret = 0; |
| 5201 | goto end; |
| 5202 | } |
| 5203 | |
| 5204 | if (!type_a) { |
| 5205 | BT_LOGW_STR("Invalid parameter: field type A is NULL."); |
| 5206 | ret = -1; |
| 5207 | goto end; |
| 5208 | } |
| 5209 | |
| 5210 | if (!type_b) { |
| 5211 | BT_LOGW_STR("Invalid parameter: field type B is NULL."); |
| 5212 | ret = -1; |
| 5213 | goto end; |
| 5214 | } |
| 5215 | |
| 5216 | if (type_a->id != type_b->id) { |
| 5217 | /* Different type IDs */ |
| 5218 | BT_LOGV("Field types differ: different IDs: " |
| 5219 | "ft-a-addr=%p, ft-b-addr=%p, " |
| 5220 | "ft-a-id=%s, ft-b-id=%s", |
| 5221 | type_a, type_b, |
| 5222 | bt_field_type_id_string(type_a->id), |
| 5223 | bt_field_type_id_string(type_b->id)); |
| 5224 | goto end; |
| 5225 | } |
| 5226 | |
| 5227 | if (type_a->id == BT_FIELD_TYPE_ID_UNKNOWN) { |
| 5228 | /* Both have unknown type IDs */ |
| 5229 | BT_LOGW_STR("Invalid parameter: field type IDs are unknown."); |
| 5230 | goto end; |
| 5231 | } |
| 5232 | |
| 5233 | ret = type_compare_funcs[type_a->id](type_a, type_b); |
| 5234 | if (ret == 1) { |
| 5235 | BT_LOGV("Field types differ: ft-a-addr=%p, ft-b-addr=%p", |
| 5236 | type_a, type_b); |
| 5237 | } |
| 5238 | |
| 5239 | end: |
| 5240 | return ret; |
| 5241 | } |
| 5242 | |
| 5243 | BT_HIDDEN |
| 5244 | int64_t bt_field_type_get_field_count(struct bt_field_type *field_type) |
| 5245 | { |
| 5246 | int64_t field_count = -1; |
| 5247 | enum bt_field_type_id type_id = bt_field_type_get_type_id(field_type); |
| 5248 | |
| 5249 | switch (type_id) { |
| 5250 | case CTF_TYPE_STRUCT: |
| 5251 | field_count = |
| 5252 | bt_field_type_structure_get_field_count(field_type); |
| 5253 | break; |
| 5254 | case CTF_TYPE_VARIANT: |
| 5255 | field_count = |
| 5256 | bt_field_type_variant_get_field_count(field_type); |
| 5257 | break; |
| 5258 | case CTF_TYPE_ARRAY: |
| 5259 | case CTF_TYPE_SEQUENCE: |
| 5260 | /* |
| 5261 | * Array and sequence types always contain a single member |
| 5262 | * (the element type). |
| 5263 | */ |
| 5264 | field_count = 1; |
| 5265 | break; |
| 5266 | default: |
| 5267 | break; |
| 5268 | } |
| 5269 | |
| 5270 | return field_count; |
| 5271 | } |
| 5272 | |
| 5273 | BT_HIDDEN |
| 5274 | struct bt_field_type *bt_field_type_get_field_at_index( |
| 5275 | struct bt_field_type *field_type, int index) |
| 5276 | { |
| 5277 | struct bt_field_type *field = NULL; |
| 5278 | enum bt_field_type_id type_id = bt_field_type_get_type_id(field_type); |
| 5279 | |
| 5280 | switch (type_id) { |
| 5281 | case CTF_TYPE_STRUCT: |
| 5282 | { |
| 5283 | int ret = bt_field_type_structure_get_field_by_index( |
| 5284 | field_type, NULL, &field, index); |
| 5285 | if (ret) { |
| 5286 | field = NULL; |
| 5287 | goto end; |
| 5288 | } |
| 5289 | break; |
| 5290 | } |
| 5291 | case CTF_TYPE_VARIANT: |
| 5292 | { |
| 5293 | int ret = bt_field_type_variant_get_field_by_index( |
| 5294 | field_type, NULL, &field, index); |
| 5295 | if (ret) { |
| 5296 | field = NULL; |
| 5297 | goto end; |
| 5298 | } |
| 5299 | break; |
| 5300 | } |
| 5301 | case CTF_TYPE_ARRAY: |
| 5302 | field = bt_field_type_array_get_element_type(field_type); |
| 5303 | break; |
| 5304 | case CTF_TYPE_SEQUENCE: |
| 5305 | field = bt_field_type_sequence_get_element_type(field_type); |
| 5306 | break; |
| 5307 | default: |
| 5308 | break; |
| 5309 | } |
| 5310 | end: |
| 5311 | return field; |
| 5312 | } |
| 5313 | |
| 5314 | BT_HIDDEN |
| 5315 | int bt_field_type_get_field_index(struct bt_field_type *field_type, |
| 5316 | const char *name) |
| 5317 | { |
| 5318 | int field_index = -1; |
| 5319 | enum bt_field_type_id type_id = bt_field_type_get_type_id(field_type); |
| 5320 | |
| 5321 | switch (type_id) { |
| 5322 | case CTF_TYPE_STRUCT: |
| 5323 | field_index = bt_field_type_structure_get_field_name_index( |
| 5324 | field_type, name); |
| 5325 | break; |
| 5326 | case CTF_TYPE_VARIANT: |
| 5327 | field_index = bt_field_type_variant_get_field_name_index( |
| 5328 | field_type, name); |
| 5329 | break; |
| 5330 | default: |
| 5331 | break; |
| 5332 | } |
| 5333 | |
| 5334 | return field_index; |
| 5335 | } |
| 5336 | |
| 5337 | struct bt_field_path *bt_field_type_variant_get_tag_field_path( |
| 5338 | struct bt_field_type *type) |
| 5339 | { |
| 5340 | struct bt_field_path *field_path = NULL; |
| 5341 | struct bt_field_type_variant *variant; |
| 5342 | |
| 5343 | if (!type) { |
| 5344 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 5345 | goto end; |
| 5346 | } |
| 5347 | |
| 5348 | if (!bt_field_type_is_variant(type)) { |
| 5349 | BT_LOGW("Invalid parameter: field type is not a variant field type: " |
| 5350 | "addr=%p, ft-id=%s", type, |
| 5351 | bt_field_type_id_string(type->id)); |
| 5352 | goto end; |
| 5353 | } |
| 5354 | |
| 5355 | variant = container_of(type, struct bt_field_type_variant, |
| 5356 | parent); |
| 5357 | field_path = bt_get(variant->tag_field_path); |
| 5358 | end: |
| 5359 | return field_path; |
| 5360 | } |
| 5361 | |
| 5362 | struct bt_field_path *bt_field_type_sequence_get_length_field_path( |
| 5363 | struct bt_field_type *type) |
| 5364 | { |
| 5365 | struct bt_field_path *field_path = NULL; |
| 5366 | struct bt_field_type_sequence *sequence; |
| 5367 | |
| 5368 | if (!type) { |
| 5369 | BT_LOGW_STR("Invalid parameter: field type is NULL."); |
| 5370 | goto end; |
| 5371 | } |
| 5372 | |
| 5373 | if (!bt_field_type_is_sequence(type)) { |
| 5374 | BT_LOGW("Invalid parameter: field type is not a sequence field type: " |
| 5375 | "addr=%p, ft-id=%s", type, |
| 5376 | bt_field_type_id_string(type->id)); |
| 5377 | goto end; |
| 5378 | } |
| 5379 | |
| 5380 | sequence = container_of(type, struct bt_field_type_sequence, |
| 5381 | parent); |
| 5382 | field_path = bt_get(sequence->length_field_path); |
| 5383 | end: |
| 5384 | return field_path; |
| 5385 | } |