6 <minyard@acm.org>
7
8 The Intelligent Platform Management Interface, or IPMI, is a
9 standard for controlling intelligent devices that monitor a system.
10 It provides for dynamic discovery of sensors in the system and the
11 ability to monitor the sensors and be informed when the sensor's
12 values change or go outside certain boundaries. It also has a
13 standardized database for field-replaceable units (FRUs) and a watchdog
14 timer.
15
16 To use this, you need an interface to an IPMI controller in your
17 system (called a Baseboard Management Controller, or BMC) and
18 management software that can use the IPMI system.
19
20 This document describes how to use the IPMI driver for Linux. If you
21 are not familiar with IPMI itself, see the web site at
22 http://www.intel.com/design/servers/ipmi/index.htm. IPMI is a big
23 subject and I can't cover it all here!
24
25 Configuration
26 -------------
27
28 The Linux IPMI driver is modular, which means you have to pick several
29 things to have it work right depending on your hardware. Most of
30 these are available in the 'Character Devices' menu then the IPMI
31 menu.
32
33 No matter what, you must pick 'IPMI top-level message handler' to use
34 IPMI. What you do beyond that depends on your needs and hardware.
35
36 The message handler does not provide any user-level interfaces.
37 Kernel code (like the watchdog) can still use it. If you need access
38 from userland, you need to select 'Device interface for IPMI' if you
39 want access through a device driver.
40
41 The driver interface depends on your hardware. If your system
42 properly provides the SMBIOS info for IPMI, the driver will detect it
43 and just work. If you have a board with a standard interface (These
44 will generally be either "KCS", "SMIC", or "BT", consult your hardware
45 manual), choose the 'IPMI SI handler' option. A driver also exists
46 for direct I2C access to the IPMI management controller. Some boards
47 support this, but it is unknown if it will work on every board. For
48 this, choose 'IPMI SMBus handler', but be ready to try to do some
49 figuring to see if it will work on your system if the SMBIOS/APCI
50 information is wrong or not present. It is fairly safe to have both
51 these enabled and let the drivers auto-detect what is present.
52
53 You should generally enable ACPI on your system, as systems with IPMI
54 can have ACPI tables describing them.
55
56 If you have a standard interface and the board manufacturer has done
57 their job correctly, the IPMI controller should be automatically
58 detected (via ACPI or SMBIOS tables) and should just work. Sadly,
59 many boards do not have this information. The driver attempts
60 standard defaults, but they may not work. If you fall into this
61 situation, you need to read the section below named 'The SI Driver' or
62 "The SMBus Driver" on how to hand-configure your system.
63
64 IPMI defines a standard watchdog timer. You can enable this with the
65 'IPMI Watchdog Timer' config option. If you compile the driver into
66 the kernel, then via a kernel command-line option you can have the
67 watchdog timer start as soon as it initializes. It also have a lot
68 of other options, see the 'Watchdog' section below for more details.
69 Note that you can also have the watchdog continue to run if it is
70 closed (by default it is disabled on close). Go into the 'Watchdog
71 Cards' menu, enable 'Watchdog Timer Support', and enable the option
72 'Disable watchdog shutdown on close'.
73
74 IPMI systems can often be powered off using IPMI commands. Select
75 'IPMI Poweroff' to do this. The driver will auto-detect if the system
76 can be powered off by IPMI. It is safe to enable this even if your
77 system doesn't support this option. This works on ATCA systems, the
78 Radisys CPI1 card, and any IPMI system that supports standard chassis
79 management commands.
80
81 If you want the driver to put an event into the event log on a panic,
82 enable the 'Generate a panic event to all BMCs on a panic' option. If
83 you want the whole panic string put into the event log using OEM
84 events, enable the 'Generate OEM events containing the panic string'
85 option.
86
87 Basic Design
88 ------------
89
90 The Linux IPMI driver is designed to be very modular and flexible, you
91 only need to take the pieces you need and you can use it in many
92 different ways. Because of that, it's broken into many chunks of
93 code. These chunks (by module name) are:
94
95 ipmi_msghandler - This is the central piece of software for the IPMI
96 system. It handles all messages, message timing, and responses. The
97 IPMI users tie into this, and the IPMI physical interfaces (called
98 System Management Interfaces, or SMIs) also tie in here. This
99 provides the kernelland interface for IPMI, but does not provide an
100 interface for use by application processes.
101
102 ipmi_devintf - This provides a userland IOCTL interface for the IPMI
103 driver, each open file for this device ties in to the message handler
104 as an IPMI user.
105
106 ipmi_si - A driver for various system interfaces. This supports KCS,
107 SMIC, and BT interfaces. Unless you have an SMBus interface or your
108 own custom interface, you probably need to use this.
109
110 ipmi_ssif - A driver for accessing BMCs on the SMBus. It uses the
111 I2C kernel driver's SMBus interfaces to send and receive IPMI messages
112 over the SMBus.
113
114 ipmi_watchdog - IPMI requires systems to have a very capable watchdog
115 timer. This driver implements the standard Linux watchdog timer
116 interface on top of the IPMI message handler.
117
118 ipmi_poweroff - Some systems support the ability to be turned off via
119 IPMI commands.
120
121 These are all individually selectable via configuration options.
122
123 Note that the KCS-only interface has been removed. The af_ipmi driver
124 is no longer supported and has been removed because it was impossible
125 to do 32 bit emulation on 64-bit kernels with it.
126
127 Much documentation for the interface is in the include files. The
128 IPMI include files are:
129
130 net/af_ipmi.h - Contains the socket interface.
131
132 linux/ipmi.h - Contains the user interface and IOCTL interface for IPMI.
133
134 linux/ipmi_smi.h - Contains the interface for system management interfaces
135 (things that interface to IPMI controllers) to use.
136
137 linux/ipmi_msgdefs.h - General definitions for base IPMI messaging.
138
139
140 Addressing
141 ----------
142
143 The IPMI addressing works much like IP addresses, you have an overlay
144 to handle the different address types. The overlay is:
145
146 struct ipmi_addr
147 {
148 int addr_type;
149 short channel;
150 char data[IPMI_MAX_ADDR_SIZE];
151 };
152
153 The addr_type determines what the address really is. The driver
154 currently understands two different types of addresses.
155
156 "System Interface" addresses are defined as:
157
158 struct ipmi_system_interface_addr
159 {
160 int addr_type;
161 short channel;
162 };
163
164 and the type is IPMI_SYSTEM_INTERFACE_ADDR_TYPE. This is used for talking
165 straight to the BMC on the current card. The channel must be
166 IPMI_BMC_CHANNEL.
167
168 Messages that are destined to go out on the IPMB bus use the
169 IPMI_IPMB_ADDR_TYPE address type. The format is
170
171 struct ipmi_ipmb_addr
172 {
173 int addr_type;
174 short channel;
175 unsigned char slave_addr;
176 unsigned char lun;
177 };
178
179 The "channel" here is generally zero, but some devices support more
180 than one channel, it corresponds to the channel as defined in the IPMI
181 spec.
182
183
184 Messages
185 --------
186
187 Messages are defined as:
188
189 struct ipmi_msg
190 {
191 unsigned char netfn;
192 unsigned char lun;
193 unsigned char cmd;
194 unsigned char *data;
195 int data_len;
196 };
197
198 The driver takes care of adding/stripping the header information. The
199 data portion is just the data to be send (do NOT put addressing info
200 here) or the response. Note that the completion code of a response is
201 the first item in "data", it is not stripped out because that is how
202 all the messages are defined in the spec (and thus makes counting the
203 offsets a little easier :-).
204
205 When using the IOCTL interface from userland, you must provide a block
206 of data for "data", fill it, and set data_len to the length of the
207 block of data, even when receiving messages. Otherwise the driver
208 will have no place to put the message.
209
210 Messages coming up from the message handler in kernelland will come in
211 as:
212
213 struct ipmi_recv_msg
214 {
215 struct list_head link;
216
217 /* The type of message as defined in the "Receive Types"
218 defines above. */
219 int recv_type;
220
221 ipmi_user_t *user;
222 struct ipmi_addr addr;
223 long msgid;
224 struct ipmi_msg msg;
225
226 /* Call this when done with the message. It will presumably free
227 the message and do any other necessary cleanup. */
228 void (*done)(struct ipmi_recv_msg *msg);
229
230 /* Place-holder for the data, don't make any assumptions about
231 the size or existence of this, since it may change. */
232 unsigned char msg_data[IPMI_MAX_MSG_LENGTH];
233 };
234
235 You should look at the receive type and handle the message
236 appropriately.
237
238
239 The Upper Layer Interface (Message Handler)
240 -------------------------------------------
241
242 The upper layer of the interface provides the users with a consistent
243 view of the IPMI interfaces. It allows multiple SMI interfaces to be
244 addressed (because some boards actually have multiple BMCs on them)
245 and the user should not have to care what type of SMI is below them.
246
247
248 Creating the User
249
250 To user the message handler, you must first create a user using
251 ipmi_create_user. The interface number specifies which SMI you want
252 to connect to, and you must supply callback functions to be called
253 when data comes in. The callback function can run at interrupt level,
254 so be careful using the callbacks. This also allows to you pass in a
255 piece of data, the handler_data, that will be passed back to you on
256 all calls.
257
258 Once you are done, call ipmi_destroy_user() to get rid of the user.
259
260 From userland, opening the device automatically creates a user, and
261 closing the device automatically destroys the user.
262
263
264 Messaging
265
266 To send a message from kernel-land, the ipmi_request() call does
267 pretty much all message handling. Most of the parameter are
268 self-explanatory. However, it takes a "msgid" parameter. This is NOT
269 the sequence number of messages. It is simply a long value that is
270 passed back when the response for the message is returned. You may
271 use it for anything you like.
272
273 Responses come back in the function pointed to by the ipmi_recv_hndl
274 field of the "handler" that you passed in to ipmi_create_user().
275 Remember again, these may be running at interrupt level. Remember to
276 look at the receive type, too.
277
278 From userland, you fill out an ipmi_req_t structure and use the
279 IPMICTL_SEND_COMMAND ioctl. For incoming stuff, you can use select()
280 or poll() to wait for messages to come in. However, you cannot use
281 read() to get them, you must call the IPMICTL_RECEIVE_MSG with the
282 ipmi_recv_t structure to actually get the message. Remember that you
283 must supply a pointer to a block of data in the msg.data field, and
284 you must fill in the msg.data_len field with the size of the data.
285 This gives the receiver a place to actually put the message.
286
287 If the message cannot fit into the data you provide, you will get an
288 EMSGSIZE error and the driver will leave the data in the receive
289 queue. If you want to get it and have it truncate the message, us
290 the IPMICTL_RECEIVE_MSG_TRUNC ioctl.
291
292 When you send a command (which is defined by the lowest-order bit of
293 the netfn per the IPMI spec) on the IPMB bus, the driver will
294 automatically assign the sequence number to the command and save the
295 command. If the response is not receive in the IPMI-specified 5
296 seconds, it will generate a response automatically saying the command
297 timed out. If an unsolicited response comes in (if it was after 5
298 seconds, for instance), that response will be ignored.
299
300 In kernelland, after you receive a message and are done with it, you
301 MUST call ipmi_free_recv_msg() on it, or you will leak messages. Note
302 that you should NEVER mess with the "done" field of a message, that is
303 required to properly clean up the message.
304
305 Note that when sending, there is an ipmi_request_supply_msgs() call
306 that lets you supply the smi and receive message. This is useful for
307 pieces of code that need to work even if the system is out of buffers
308 (the watchdog timer uses this, for instance). You supply your own
309 buffer and own free routines. This is not recommended for normal use,
310 though, since it is tricky to manage your own buffers.
311
312
313 Events and Incoming Commands
314
315 The driver takes care of polling for IPMI events and receiving
316 commands (commands are messages that are not responses, they are
317 commands that other things on the IPMB bus have sent you). To receive
318 these, you must register for them, they will not automatically be sent
319 to you.
320
321 To receive events, you must call ipmi_set_gets_events() and set the
322 "val" to non-zero. Any events that have been received by the driver
323 since startup will immediately be delivered to the first user that
324 registers for events. After that, if multiple users are registered
325 for events, they will all receive all events that come in.
326
327 For receiving commands, you have to individually register commands you
328 want to receive. Call ipmi_register_for_cmd() and supply the netfn
329 and command name for each command you want to receive. You also
330 specify a bitmask of the channels you want to receive the command from
331 (or use IPMI_CHAN_ALL for all channels if you don't care). Only one
332 user may be registered for each netfn/cmd/channel, but different users
333 may register for different commands, or the same command if the
334 channel bitmasks do not overlap.
335
336 From userland, equivalent IOCTLs are provided to do these functions.
337
338
339 The Lower Layer (SMI) Interface
340 -------------------------------
341
342 As mentioned before, multiple SMI interfaces may be registered to the
343 message handler, each of these is assigned an interface number when
344 they register with the message handler. They are generally assigned
345 in the order they register, although if an SMI unregisters and then
346 another one registers, all bets are off.
347
348 The ipmi_smi.h defines the interface for management interfaces, see
349 that for more details.
350
351
352 The SI Driver
353 -------------
354
355 The SI driver allows up to 4 KCS or SMIC interfaces to be configured
356 in the system. By default, scan the ACPI tables for interfaces, and
357 if it doesn't find any the driver will attempt to register one KCS
358 interface at the spec-specified I/O port 0xca2 without interrupts.
359 You can change this at module load time (for a module) with:
360
361 modprobe ipmi_si.o type=<type1>,<type2>....
362 ports=<port1>,<port2>... addrs=<addr1>,<addr2>...
363 irqs=<irq1>,<irq2>...
364 regspacings=<sp1>,<sp2>,... regsizes=<size1>,<size2>,...
365 regshifts=<shift1>,<shift2>,...
366 slave_addrs=<addr1>,<addr2>,...
367 force_kipmid=<enable1>,<enable2>,...
368 kipmid_max_busy_us=<ustime1>,<ustime2>,...
369 unload_when_empty=[0|1]
370 trydefaults=[0|1] trydmi=[0|1] tryacpi=[0|1]
371 tryplatform=[0|1] trypci=[0|1]
372
373 Each of these except try... items is a list, the first item for the
374 first interface, second item for the second interface, etc.
375
376 The si_type may be either "kcs", "smic", or "bt". If you leave it blank, it
377 defaults to "kcs".
378
379 If you specify addrs as non-zero for an interface, the driver will
380 use the memory address given as the address of the device. This
381 overrides si_ports.
382
383 If you specify ports as non-zero for an interface, the driver will
384 use the I/O port given as the device address.
385
386 If you specify irqs as non-zero for an interface, the driver will
387 attempt to use the given interrupt for the device.
388
389 trydefaults sets whether the standard IPMI interface at 0xca2 and
390 any interfaces specified by ACPE are tried. By default, the driver
391 tries it, set this value to zero to turn this off.
392
393 The other try... items disable discovery by their corresponding
394 names. These are all enabled by default, set them to zero to disable
395 them. The tryplatform disables openfirmware.
396
397 The next three parameters have to do with register layout. The
398 registers used by the interfaces may not appear at successive
399 locations and they may not be in 8-bit registers. These parameters
400 allow the layout of the data in the registers to be more precisely
401 specified.
402
403 The regspacings parameter give the number of bytes between successive
404 register start addresses. For instance, if the regspacing is set to 4
405 and the start address is 0xca2, then the address for the second
406 register would be 0xca6. This defaults to 1.
407
408 The regsizes parameter gives the size of a register, in bytes. The
409 data used by IPMI is 8-bits wide, but it may be inside a larger
410 register. This parameter allows the read and write type to specified.
411 It may be 1, 2, 4, or 8. The default is 1.
412
413 Since the register size may be larger than 32 bits, the IPMI data may not
414 be in the lower 8 bits. The regshifts parameter give the amount to shift
415 the data to get to the actual IPMI data.
416
417 The slave_addrs specifies the IPMI address of the local BMC. This is
418 usually 0x20 and the driver defaults to that, but in case it's not, it
419 can be specified when the driver starts up.
420
421 The force_ipmid parameter forcefully enables (if set to 1) or disables
422 (if set to 0) the kernel IPMI daemon. Normally this is auto-detected
423 by the driver, but systems with broken interrupts might need an enable,
424 or users that don't want the daemon (don't need the performance, don't
425 want the CPU hit) can disable it.
426
427 If unload_when_empty is set to 1, the driver will be unloaded if it
428 doesn't find any interfaces or all the interfaces fail to work. The
429 default is one. Setting to 0 is useful with the hotmod, but is
430 obviously only useful for modules.
431
432 When compiled into the kernel, the parameters can be specified on the
433 kernel command line as:
434
435 ipmi_si.type=<type1>,<type2>...
436 ipmi_si.ports=<port1>,<port2>... ipmi_si.addrs=<addr1>,<addr2>...
437 ipmi_si.irqs=<irq1>,<irq2>... ipmi_si.trydefaults=[0|1]
438 ipmi_si.regspacings=<sp1>,<sp2>,...
439 ipmi_si.regsizes=<size1>,<size2>,...
440 ipmi_si.regshifts=<shift1>,<shift2>,...
441 ipmi_si.slave_addrs=<addr1>,<addr2>,...
442 ipmi_si.force_kipmid=<enable1>,<enable2>,...
443 ipmi_si.kipmid_max_busy_us=<ustime1>,<ustime2>,...
444
445 It works the same as the module parameters of the same names.
446
447 By default, the driver will attempt to detect any device specified by
448 ACPI, and if none of those then a KCS device at the spec-specified
449 0xca2. If you want to turn this off, set the "trydefaults" option to
450 false.
451
452 If your IPMI interface does not support interrupts and is a KCS or
453 SMIC interface, the IPMI driver will start a kernel thread for the
454 interface to help speed things up. This is a low-priority kernel
455 thread that constantly polls the IPMI driver while an IPMI operation
456 is in progress. The force_kipmid module parameter will all the user to
457 force this thread on or off. If you force it off and don't have
458 interrupts, the driver will run VERY slowly. Don't blame me,
459 these interfaces suck.
460
461 Unfortunately, this thread can use a lot of CPU depending on the
462 interface's performance. This can waste a lot of CPU and cause
463 various issues with detecting idle CPU and using extra power. To
464 avoid this, the kipmid_max_busy_us sets the maximum amount of time, in
465 microseconds, that kipmid will spin before sleeping for a tick. This
466 value sets a balance between performance and CPU waste and needs to be
467 tuned to your needs. Maybe, someday, auto-tuning will be added, but
468 that's not a simple thing and even the auto-tuning would need to be
469 tuned to the user's desired performance.
470
471 The driver supports a hot add and remove of interfaces. This way,
472 interfaces can be added or removed after the kernel is up and running.
473 This is done using /sys/modules/ipmi_si/parameters/hotmod, which is a
474 write-only parameter. You write a string to this interface. The string
475 has the format:
476 <op1>[:op2[:op3...]]
477 The "op"s are:
478 add|remove,kcs|bt|smic,mem|i/o,<address>[,<opt1>[,<opt2>[,...]]]
479 You can specify more than one interface on the line. The "opt"s are:
480 rsp=<regspacing>
481 rsi=<regsize>
482 rsh=<regshift>
483 irq=<irq>
484 ipmb=<ipmb slave addr>
485 and these have the same meanings as discussed above. Note that you
486 can also use this on the kernel command line for a more compact format
487 for specifying an interface. Note that when removing an interface,
488 only the first three parameters (si type, address type, and address)
489 are used for the comparison. Any options are ignored for removing.
490
491 The SMBus Driver (SSIF)
492 -----------------------
493
494 The SMBus driver allows up to 4 SMBus devices to be configured in the
495 system. By default, the driver will only register with something it
496 finds in DMI or ACPI tables. You can change this
497 at module load time (for a module) with:
498
499 modprobe ipmi_ssif.o
500 addr=<i2caddr1>[,<i2caddr2>[,...]]
501 adapter=<adapter1>[,<adapter2>[...]]
502 dbg=<flags1>,<flags2>...
503 slave_addrs=<addr1>,<addr2>,...
504 [dbg_probe=1]
505
506 The addresses are normal I2C addresses. The adapter is the string
507 name of the adapter, as shown in /sys/class/i2c-adapter/i2c-<n>/name.
508 It is *NOT* i2c-<n> itself.
509
510 The debug flags are bit flags for each BMC found, they are:
511 IPMI messages: 1, driver state: 2, timing: 4, I2C probe: 8
512
513 Setting dbg_probe to 1 will enable debugging of the probing and
514 detection process for BMCs on the SMBusses.
515
516 The slave_addrs specifies the IPMI address of the local BMC. This is
517 usually 0x20 and the driver defaults to that, but in case it's not, it
518 can be specified when the driver starts up.
519
520 Discovering the IPMI compliant BMC on the SMBus can cause devices on
521 the I2C bus to fail. The SMBus driver writes a "Get Device ID" IPMI
522 message as a block write to the I2C bus and waits for a response.
523 This action can be detrimental to some I2C devices. It is highly
524 recommended that the known I2C address be given to the SMBus driver in
525 the smb_addr parameter unless you have DMI or ACPI data to tell the
526 driver what to use.
527
528 When compiled into the kernel, the addresses can be specified on the
529 kernel command line as:
530
531 ipmb_ssif.addr=<i2caddr1>[,<i2caddr2>[...]]
532 ipmi_ssif.adapter=<adapter1>[,<adapter2>[...]]
533 ipmi_ssif.dbg=<flags1>[,<flags2>[...]]
534 ipmi_ssif.dbg_probe=1
535 ipmi_ssif.slave_addrs=<addr1>[,<addr2>[...]]
536
537 These are the same options as on the module command line.
538
539 The I2C driver does not support non-blocking access or polling, so
540 this driver cannod to IPMI panic events, extend the watchdog at panic
541 time, or other panic-related IPMI functions without special kernel
542 patches and driver modifications. You can get those at the openipmi
543 web page.
544
545 The driver supports a hot add and remove of interfaces through the I2C
546 sysfs interface.
547
548 Other Pieces
549 ------------
550
551 Get the detailed info related with the IPMI device
552 --------------------------------------------------
553
554 Some users need more detailed information about a device, like where
555 the address came from or the raw base device for the IPMI interface.
556 You can use the IPMI smi_watcher to catch the IPMI interfaces as they
557 come or go, and to grab the information, you can use the function
558 ipmi_get_smi_info(), which returns the following structure:
559
560 struct ipmi_smi_info {
561 enum ipmi_addr_src addr_src;
562 struct device *dev;
563 union {
564 struct {
565 void *acpi_handle;
566 } acpi_info;
567 } addr_info;
568 };
569
570 Currently special info for only for SI_ACPI address sources is
571 returned. Others may be added as necessary.
572
573 Note that the dev pointer is included in the above structure, and
574 assuming ipmi_smi_get_info returns success, you must call put_device
575 on the dev pointer.
576
577
578 Watchdog
579 --------
580
581 A watchdog timer is provided that implements the Linux-standard
582 watchdog timer interface. It has three module parameters that can be
583 used to control it:
584
585 modprobe ipmi_watchdog timeout=<t> pretimeout=<t> action=<action type>
586 preaction=<preaction type> preop=<preop type> start_now=x
587 nowayout=x ifnum_to_use=n
588
589 ifnum_to_use specifies which interface the watchdog timer should use.
590 The default is -1, which means to pick the first one registered.
591
592 The timeout is the number of seconds to the action, and the pretimeout
593 is the amount of seconds before the reset that the pre-timeout panic will
594 occur (if pretimeout is zero, then pretimeout will not be enabled). Note
595 that the pretimeout is the time before the final timeout. So if the
596 timeout is 50 seconds and the pretimeout is 10 seconds, then the pretimeout
597 will occur in 40 second (10 seconds before the timeout).
598
599 The action may be "reset", "power_cycle", or "power_off", and
600 specifies what to do when the timer times out, and defaults to
601 "reset".
602
603 The preaction may be "pre_smi" for an indication through the SMI
604 interface, "pre_int" for an indication through the SMI with an
605 interrupts, and "pre_nmi" for a NMI on a preaction. This is how
606 the driver is informed of the pretimeout.
607
608 The preop may be set to "preop_none" for no operation on a pretimeout,
609 "preop_panic" to set the preoperation to panic, or "preop_give_data"
610 to provide data to read from the watchdog device when the pretimeout
611 occurs. A "pre_nmi" setting CANNOT be used with "preop_give_data"
612 because you can't do data operations from an NMI.
613
614 When preop is set to "preop_give_data", one byte comes ready to read
615 on the device when the pretimeout occurs. Select and fasync work on
616 the device, as well.
617
618 If start_now is set to 1, the watchdog timer will start running as
619 soon as the driver is loaded.
620
621 If nowayout is set to 1, the watchdog timer will not stop when the
622 watchdog device is closed. The default value of nowayout is true
623 if the CONFIG_WATCHDOG_NOWAYOUT option is enabled, or false if not.
624
625 When compiled into the kernel, the kernel command line is available
626 for configuring the watchdog:
627
628 ipmi_watchdog.timeout=<t> ipmi_watchdog.pretimeout=<t>
629 ipmi_watchdog.action=<action type>
630 ipmi_watchdog.preaction=<preaction type>
631 ipmi_watchdog.preop=<preop type>
632 ipmi_watchdog.start_now=x
633 ipmi_watchdog.nowayout=x
634
635 The options are the same as the module parameter options.
636
637 The watchdog will panic and start a 120 second reset timeout if it
638 gets a pre-action. During a panic or a reboot, the watchdog will
639 start a 120 timer if it is running to make sure the reboot occurs.
640
641 Note that if you use the NMI preaction for the watchdog, you MUST NOT
642 use the nmi watchdog. There is no reasonable way to tell if an NMI
643 comes from the IPMI controller, so it must assume that if it gets an
644 otherwise unhandled NMI, it must be from IPMI and it will panic
645 immediately.
646
647 Once you open the watchdog timer, you must write a 'V' character to the
648 device to close it, or the timer will not stop. This is a new semantic
649 for the driver, but makes it consistent with the rest of the watchdog
650 drivers in Linux.
651
652
653 Panic Timeouts
654 --------------
655
656 The OpenIPMI driver supports the ability to put semi-custom and custom
657 events in the system event log if a panic occurs. if you enable the
658 'Generate a panic event to all BMCs on a panic' option, you will get
659 one event on a panic in a standard IPMI event format. If you enable
660 the 'Generate OEM events containing the panic string' option, you will
661 also get a bunch of OEM events holding the panic string.
662
663
664 The field settings of the events are:
665 * Generator ID: 0x21 (kernel)
666 * EvM Rev: 0x03 (this event is formatting in IPMI 1.0 format)
667 * Sensor Type: 0x20 (OS critical stop sensor)
668 * Sensor #: The first byte of the panic string (0 if no panic string)
669 * Event Dir | Event Type: 0x6f (Assertion, sensor-specific event info)
670 * Event Data 1: 0xa1 (Runtime stop in OEM bytes 2 and 3)
671 * Event data 2: second byte of panic string
672 * Event data 3: third byte of panic string
673 See the IPMI spec for the details of the event layout. This event is
674 always sent to the local management controller. It will handle routing
675 the message to the right place
676
677 Other OEM events have the following format:
678 Record ID (bytes 0-1): Set by the SEL.
679 Record type (byte 2): 0xf0 (OEM non-timestamped)
680 byte 3: The slave address of the card saving the panic
681 byte 4: A sequence number (starting at zero)
682 The rest of the bytes (11 bytes) are the panic string. If the panic string
683 is longer than 11 bytes, multiple messages will be sent with increasing
684 sequence numbers.
685
686 Because you cannot send OEM events using the standard interface, this
687 function will attempt to find an SEL and add the events there. It
688 will first query the capabilities of the local management controller.
689 If it has an SEL, then they will be stored in the SEL of the local
690 management controller. If not, and the local management controller is
691 an event generator, the event receiver from the local management
692 controller will be queried and the events sent to the SEL on that
693 device. Otherwise, the events go nowhere since there is nowhere to
694 send them.
695
696
697 Poweroff
698 --------
699
700 If the poweroff capability is selected, the IPMI driver will install
701 a shutdown function into the standard poweroff function pointer. This
702 is in the ipmi_poweroff module. When the system requests a powerdown,
703 it will send the proper IPMI commands to do this. This is supported on
704 several platforms.
705
706 There is a module parameter named "poweroff_powercycle" that may
707 either be zero (do a power down) or non-zero (do a power cycle, power
708 the system off, then power it on in a few seconds). Setting
709 ipmi_poweroff.poweroff_control=x will do the same thing on the kernel
710 command line. The parameter is also available via the proc filesystem
711 in /proc/sys/dev/ipmi/poweroff_powercycle. Note that if the system
712 does not support power cycling, it will always do the power off.
713
714 The "ifnum_to_use" parameter specifies which interface the poweroff
715 code should use. The default is -1, which means to pick the first one
716 registered.
717
718 Note that if you have ACPI enabled, the system will prefer using ACPI to
719 power off.
This page took 0.046936 seconds and 5 git commands to generate.