1 MVP MP Macro Assembler Version 1.13 Mon Feb 10 20:13:33 1997
2 Copyright (c) 1993-1995 Texas Instruments Incorporated
6 1 ; Test signed and unsigned addition instruction.
7 2 ; Test boundary conditions to ensure proper handling.
8 3 ; Note that unsigned addition still uses signed immediates.
10 5 00000000 62FB000A add r10,r11,r12 ; Register form
11 6 00000004 20AC3FFF add 16383,r2,r4 ; Maximum positive short signed immediate
12 7 00000008 212C4000 add -16384,r4,r4 ; Minimum negative short signed immediate
13 8 0000000C 317B1000 add 16384,r5,r6 ; Minimum positive long signed immediate
15 9 00000014 41FB1000 add -16385,r7,r8 ; Maximum negative short signed immediate
17 10 0000001C 5ABB1000 add 2147483647,r10,r11 ; Maximum positive long signed immediate
19 11 00000024 6B3B1000 add -2147483648,r12,r13 ; Minimum positive long signed immediate
22 13 0000002C 62FB200A addu r10,r11,r12 ; Register form
23 14 00000030 20ACBFFF addu 16383,r2,r4 ; Maximum positive short signed immediate
24 15 00000034 212CC000 addu -16384,r4,r4 ; Minimum negative short signed immediate
25 16 00000038 317B3000 addu 16384,r5,r6 ; Minimum positive long signed immediate
27 17 00000040 41FB3000 addu -16385,r7,r8 ; Maximum negative short signed immediate
29 18 00000048 5ABB3000 addu 2147483647,r10,r11 ; Maximum positive long signed immediate
31 19 00000050 6B3B3000 addu -2147483648,r12,r13 ; Minimum positive long signed immediate
34 No Errors, No Warnings