ptrace_event(PTRACE_EVENT_SECCOMP, data);
/*
* The delivery of a fatal signal during event
- * notification may silently skip tracer notification.
- * Terminating the task now avoids executing a system
- * call that may not be intended.
+ * notification may silently skip tracer notification,
+ * which could leave us with a potentially unmodified
+ * syscall that the tracer would have liked to have
+ * changed. Since the process is about to die, we just
+ * force the syscall to be skipped and let the signal
+ * kill the process and correctly handle any tracer exit
+ * notifications.
*/
if (fatal_signal_pending(current))
- do_exit(SIGSYS);
+ goto skip;
/* Check if the tracer forced the syscall to be skipped. */
this_syscall = syscall_get_nr(current, task_pt_regs(current));
if (this_syscall < 0)