- * Check if the global socket is available. If yes, error is returned.
+ * Check if the global socket is available, and if a daemon is answering
+ * at the other side. If yes, error is returned.
*/
static int check_existing_daemon(void)
{
int ret;
- ret = access(client_unix_sock_path, F_OK);
- if (ret == 0) {
- ret = access(apps_unix_sock_path, F_OK);
- }
-
- return ret;
+ if (access(client_unix_sock_path, F_OK) < 0 &&
+ access(apps_unix_sock_path, F_OK) < 0)
+ return 0;
+ /* Is there anybody out there ? */
+ if (lttng_session_daemon_alive())
+ return -EEXIST;
+ else
+ return 0;
}
/*
DBG("Application socket path %s", apps_unix_sock_path);
/*
- * See if daemon already exist. If any of the two socket needed by the
- * daemon are present, this test fails. However, if the daemon is killed
- * with a SIGKILL, those unix socket must be unlinked by hand.
+ * See if daemon already exist.
*/
- if ((ret = check_existing_daemon()) == 0) {
+ if ((ret = check_existing_daemon()) < 0) {
ERR("Already running daemon.\n");
/*
* We do not goto exit because we must not cleanup()