goto error;
}
- real_params = bt_value_map_extend(
+ ret = bt_value_map_extend(&real_params,
bt_value_borrow_from_private(default_params), params);
- if (!real_params) {
+ if (ret) {
BT_LOGE("Cannot extend default parameters map value: "
"muxer-comp-addr=%p, def-params-addr=%p, "
"params-addr=%p", muxer_comp, default_params,
goto error;
}
- ret = bt_value_bool_get(assume_absolute_clock_classes, &bool_val);
- BT_ASSERT(ret == 0);
+ bool_val = bt_value_bool_get(assume_absolute_clock_classes);
muxer_comp->assume_absolute_clock_classes = (bool) bool_val;
BT_LOGD("Configured muxer component: muxer-comp-addr=%p, "
"assume-absolute-clock-classes=%d",