Commit | Line | Data |
---|---|---|
ca9f27f3 FD |
1 | /* |
2 | * Babeltrace - Trace IR data object copy | |
3 | * | |
4 | * Copyright (c) 2015-2019 EfficiOS Inc. and Linux Foundation | |
5 | * Copyright (c) 2019 Francis Deslauriers <francis.deslauriers@efficios.com> | |
6 | * | |
7 | * Permission is hereby granted, free of charge, to any person obtaining a copy | |
8 | * of this software and associated documentation files (the "Software"), to deal | |
9 | * in the Software without restriction, including without limitation the rights | |
10 | * to use, copy, modify, merge, publish, distribute, sublicense, and/or sell | |
11 | * copies of the Software, and to permit persons to whom the Software is | |
12 | * furnished to do so, subject to the following conditions: | |
13 | * | |
14 | * The above copyright notice and this permission notice shall be included in | |
15 | * all copies or substantial portions of the Software. | |
16 | * | |
17 | * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR | |
18 | * IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, | |
19 | * FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE | |
20 | * AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER | |
21 | * LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, | |
22 | * OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE | |
23 | * SOFTWARE. | |
24 | */ | |
25 | ||
350ad6c1 | 26 | #define BT_LOG_TAG "PLUGIN/FLT.LTTNG-UTILS.DEBUG-INFO/TRACE-IR-DATA-COPY" |
ca9f27f3 FD |
27 | #include "logging.h" |
28 | ||
29 | #include <inttypes.h> | |
30 | #include <stdint.h> | |
31 | ||
578e048b | 32 | #include "common/assert.h" |
ca9f27f3 FD |
33 | |
34 | #include "trace-ir-data-copy.h" | |
35 | ||
36 | BT_HIDDEN | |
37 | void copy_trace_content(const bt_trace *in_trace, bt_trace *out_trace) | |
38 | { | |
39 | bt_trace_status status; | |
40 | const char *trace_name; | |
41 | ||
42 | BT_LOGD("Copying content of trace: in-t-addr=%p, out-t-addr=%p", | |
43 | in_trace, out_trace); | |
44 | ||
45 | trace_name = bt_trace_get_name(in_trace); | |
46 | /* Copy the trace name. */ | |
47 | if (trace_name) { | |
48 | status = bt_trace_set_name(out_trace, trace_name); | |
49 | if (status != BT_TRACE_STATUS_OK) { | |
50 | BT_LOGE("Cannot set trace's name: trace-addr=%p, name=\"%s\"", | |
51 | out_trace, trace_name); | |
52 | goto end; | |
53 | } | |
54 | } | |
55 | ||
56 | BT_LOGD("Copied content of trace: in-t-addr=%p, out-t-addr=%p", | |
57 | in_trace, out_trace); | |
58 | end: | |
59 | return; | |
60 | } | |
61 | ||
62 | BT_HIDDEN | |
63 | void copy_stream_content(const bt_stream *in_stream, bt_stream *out_stream) | |
64 | { | |
ca9f27f3 FD |
65 | const char *stream_name; |
66 | bt_stream_status status; | |
67 | ||
68 | BT_LOGD("Copying content of stream: in-s-addr=%p, out-s-addr=%p", | |
69 | in_stream, out_stream); | |
70 | ||
ca9f27f3 FD |
71 | stream_name = bt_stream_get_name(in_stream); |
72 | if (stream_name) { | |
73 | status = bt_stream_set_name(out_stream, stream_name); | |
74 | if (status != BT_STREAM_STATUS_OK) { | |
75 | BT_LOGE("Cannot set stream's name: stream-addr=%p, " | |
76 | "name=%s", out_stream, stream_name); | |
77 | goto end; | |
78 | } | |
79 | } | |
80 | ||
81 | BT_LOGD("Copied content of stream: in-s-addr=%p, out-s-addr=%p", | |
82 | in_stream, out_stream); | |
83 | end: | |
84 | return; | |
85 | } | |
86 | ||
87 | BT_HIDDEN | |
88 | void copy_packet_content(const bt_packet *in_packet, bt_packet *out_packet) | |
89 | { | |
90 | const bt_field *in_context_field; | |
91 | bt_field *out_context_field; | |
92 | ||
93 | BT_LOGD("Copying content of packet: in-p-addr=%p, out-p-addr=%p", | |
94 | in_packet, out_packet); | |
95 | ||
96 | /* Copy context field. */ | |
97 | in_context_field = bt_packet_borrow_context_field_const(in_packet); | |
98 | if (in_context_field) { | |
99 | out_context_field = bt_packet_borrow_context_field(out_packet); | |
100 | BT_ASSERT(out_context_field); | |
101 | copy_field_content(in_context_field, out_context_field); | |
102 | } | |
103 | ||
104 | BT_LOGD("Copied content of packet: in-p-addr=%p, out-p-addr=%p", | |
105 | in_packet, out_packet); | |
106 | return; | |
107 | } | |
108 | ||
109 | BT_HIDDEN | |
110 | void copy_event_content(const bt_event *in_event, bt_event *out_event) | |
111 | { | |
112 | const bt_field *in_common_ctx_field, *in_specific_ctx_field, | |
113 | *in_payload_field; | |
114 | bt_field *out_common_ctx_field, *out_specific_ctx_field, | |
115 | *out_payload_field; | |
116 | ||
117 | BT_LOGD("Copying content of event: in-e-addr=%p, out-e-addr=%p", | |
118 | in_event, out_event); | |
119 | in_common_ctx_field = | |
120 | bt_event_borrow_common_context_field_const(in_event); | |
121 | if (in_common_ctx_field) { | |
122 | out_common_ctx_field = | |
123 | bt_event_borrow_common_context_field(out_event); | |
124 | BT_ASSERT(out_common_ctx_field); | |
125 | copy_field_content(in_common_ctx_field, | |
126 | out_common_ctx_field); | |
127 | } | |
128 | ||
129 | in_specific_ctx_field = | |
130 | bt_event_borrow_specific_context_field_const(in_event); | |
131 | if (in_specific_ctx_field) { | |
132 | out_specific_ctx_field = | |
133 | bt_event_borrow_specific_context_field(out_event); | |
134 | BT_ASSERT(out_specific_ctx_field); | |
135 | copy_field_content(in_specific_ctx_field, | |
136 | out_specific_ctx_field); | |
137 | } | |
138 | ||
139 | in_payload_field = bt_event_borrow_payload_field_const(in_event); | |
140 | if (in_payload_field) { | |
141 | out_payload_field = bt_event_borrow_payload_field(out_event); | |
142 | BT_ASSERT(out_payload_field); | |
143 | copy_field_content(in_payload_field, | |
144 | out_payload_field); | |
145 | } | |
146 | ||
147 | BT_LOGD("Copied content of event: in-e-addr=%p, out-e-addr=%p", | |
148 | in_event, out_event); | |
149 | } | |
150 | ||
151 | BT_HIDDEN | |
152 | void copy_field_content(const bt_field *in_field, bt_field *out_field) | |
153 | { | |
154 | bt_field_class_type in_fc_type, out_fc_type; | |
155 | ||
156 | in_fc_type = bt_field_get_class_type(in_field); | |
157 | out_fc_type = bt_field_get_class_type(out_field); | |
158 | BT_ASSERT(in_fc_type == out_fc_type); | |
159 | ||
3f7d4d90 | 160 | BT_LOGV("Copying content of field: in-f-addr=%p, out-f-addr=%p", |
ca9f27f3 FD |
161 | in_field, out_field); |
162 | switch (in_fc_type) { | |
163 | case BT_FIELD_CLASS_TYPE_UNSIGNED_INTEGER: | |
164 | case BT_FIELD_CLASS_TYPE_UNSIGNED_ENUMERATION: | |
165 | bt_field_unsigned_integer_set_value(out_field, | |
166 | bt_field_unsigned_integer_get_value(in_field)); | |
167 | break; | |
168 | case BT_FIELD_CLASS_TYPE_SIGNED_INTEGER: | |
169 | case BT_FIELD_CLASS_TYPE_SIGNED_ENUMERATION: | |
170 | bt_field_signed_integer_set_value(out_field, | |
171 | bt_field_signed_integer_get_value(in_field)); | |
172 | break; | |
173 | case BT_FIELD_CLASS_TYPE_REAL: | |
174 | bt_field_real_set_value(out_field, | |
175 | bt_field_real_get_value(in_field)); | |
176 | break; | |
177 | case BT_FIELD_CLASS_TYPE_STRING: | |
178 | { | |
179 | const char *str = bt_field_string_get_value(in_field); | |
180 | bt_field_status status = bt_field_string_set_value(out_field, str); | |
181 | if (status != BT_FIELD_STATUS_OK) { | |
182 | BT_LOGE("Cannot set string field's value: " | |
183 | "str-field-addr=%p, str=%s" PRId64, | |
184 | out_field, str); | |
185 | } | |
186 | break; | |
187 | } | |
188 | case BT_FIELD_CLASS_TYPE_STRUCTURE: | |
189 | { | |
190 | uint64_t i, nb_member_struct; | |
191 | const bt_field *in_member_field; | |
192 | bt_field *out_member_field; | |
1e6fd1d7 | 193 | const bt_field_class *in_field_class; |
ca9f27f3 FD |
194 | const char *in_member_name; |
195 | ||
196 | in_field_class = bt_field_borrow_class_const(in_field); | |
197 | nb_member_struct = bt_field_class_structure_get_member_count( | |
198 | in_field_class); | |
199 | ||
200 | /* | |
201 | * Iterate over the fields by names in the input field to avoid | |
202 | * problem if the struct fields are not in the same order after | |
203 | * the debug-info was added. | |
204 | */ | |
205 | for (i = 0; i < nb_member_struct; i++) { | |
1e6fd1d7 PP |
206 | const bt_field_class_structure_member *member = |
207 | bt_field_class_structure_borrow_member_by_index_const( | |
208 | in_field_class, i); | |
ca9f27f3 | 209 | |
1e6fd1d7 PP |
210 | in_member_name = |
211 | bt_field_class_structure_member_get_name( | |
212 | member); | |
ca9f27f3 FD |
213 | in_member_field = |
214 | bt_field_structure_borrow_member_field_by_name_const( | |
215 | in_field, in_member_name); | |
216 | out_member_field = | |
217 | bt_field_structure_borrow_member_field_by_name( | |
218 | out_field, in_member_name); | |
219 | ||
220 | copy_field_content(in_member_field, | |
221 | out_member_field); | |
222 | } | |
223 | break; | |
224 | } | |
225 | case BT_FIELD_CLASS_TYPE_DYNAMIC_ARRAY: | |
226 | /* fall through */ | |
227 | case BT_FIELD_CLASS_TYPE_STATIC_ARRAY: | |
228 | { | |
229 | const bt_field *in_element_field; | |
230 | bt_field *out_element_field; | |
231 | uint64_t i, array_len; | |
232 | bt_field_status status; | |
233 | ||
234 | array_len = bt_field_array_get_length(in_field); | |
235 | ||
236 | if (in_fc_type == BT_FIELD_CLASS_TYPE_DYNAMIC_ARRAY) { | |
237 | status = bt_field_dynamic_array_set_length(out_field, | |
238 | array_len); | |
239 | if (status != BT_FIELD_STATUS_OK) { | |
240 | BT_LOGE("Cannot set dynamic array field's " | |
241 | "length field: field-addr=%p, " | |
242 | "length=%" PRIu64, out_field, array_len); | |
243 | } | |
244 | } | |
245 | ||
246 | for (i = 0; i < array_len; i++) { | |
247 | in_element_field = | |
248 | bt_field_array_borrow_element_field_by_index_const( | |
249 | in_field, i); | |
250 | out_element_field = | |
251 | bt_field_array_borrow_element_field_by_index( | |
252 | out_field, i); | |
253 | copy_field_content(in_element_field, out_element_field); | |
254 | } | |
255 | break; | |
256 | } | |
257 | case BT_FIELD_CLASS_TYPE_VARIANT: | |
258 | { | |
259 | bt_field_status status; | |
260 | uint64_t in_selected_option_idx; | |
261 | const bt_field *in_option_field; | |
262 | bt_field *out_option_field; | |
263 | ||
264 | in_selected_option_idx = | |
265 | bt_field_variant_get_selected_option_field_index( | |
266 | in_field); | |
267 | status = bt_field_variant_select_option_field(out_field, | |
268 | in_selected_option_idx); | |
269 | if (status != BT_FIELD_STATUS_OK) { | |
270 | BT_LOGE("Cannot select variant field's option field: " | |
271 | "var-field-addr=%p, opt-index=%" PRId64, | |
272 | out_field, in_selected_option_idx); | |
273 | } | |
274 | ||
275 | in_option_field = bt_field_variant_borrow_selected_option_field_const(in_field); | |
276 | out_option_field = bt_field_variant_borrow_selected_option_field(out_field); | |
277 | ||
278 | copy_field_content(in_option_field, out_option_field); | |
279 | ||
280 | break; | |
281 | } | |
282 | default: | |
283 | abort(); | |
284 | } | |
3f7d4d90 | 285 | BT_LOGV("Copied content of field: in-f-addr=%p, out-f-addr=%p", |
ca9f27f3 FD |
286 | in_field, out_field); |
287 | } |