lib: allow a single mapped clock class within a stream class
[babeltrace.git] / lib / ctf-ir / trace.c
1 /*
2 * trace.c
3 *
4 * Babeltrace CTF IR - Trace
5 *
6 * Copyright 2014 Jérémie Galarneau <jeremie.galarneau@efficios.com>
7 *
8 * Author: Jérémie Galarneau <jeremie.galarneau@efficios.com>
9 *
10 * Permission is hereby granted, free of charge, to any person obtaining a copy
11 * of this software and associated documentation files (the "Software"), to deal
12 * in the Software without restriction, including without limitation the rights
13 * to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
14 * copies of the Software, and to permit persons to whom the Software is
15 * furnished to do so, subject to the following conditions:
16 *
17 * The above copyright notice and this permission notice shall be included in
18 * all copies or substantial portions of the Software.
19 *
20 * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
21 * IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
22 * FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
23 * AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
24 * LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
25 * OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
26 * SOFTWARE.
27 */
28
29 #define BT_LOG_TAG "TRACE"
30 #include <babeltrace/lib-logging-internal.h>
31
32 #include <babeltrace/ctf-ir/trace-internal.h>
33 #include <babeltrace/ctf-ir/clock-class-internal.h>
34 #include <babeltrace/ctf-ir/stream-internal.h>
35 #include <babeltrace/ctf-ir/stream-class-internal.h>
36 #include <babeltrace/ctf-ir/event-internal.h>
37 #include <babeltrace/ctf-ir/event-class.h>
38 #include <babeltrace/ctf-ir/event-class-internal.h>
39 #include <babeltrace/ctf-writer/functor-internal.h>
40 #include <babeltrace/ctf-writer/clock-internal.h>
41 #include <babeltrace/ctf-ir/field-types-internal.h>
42 #include <babeltrace/ctf-ir/attributes-internal.h>
43 #include <babeltrace/ctf-ir/validation-internal.h>
44 #include <babeltrace/ctf-ir/visitor-internal.h>
45 #include <babeltrace/ctf-ir/utils.h>
46 #include <babeltrace/ctf-ir/utils-internal.h>
47 #include <babeltrace/compiler-internal.h>
48 #include <babeltrace/values.h>
49 #include <babeltrace/values-internal.h>
50 #include <babeltrace/ref.h>
51 #include <babeltrace/types.h>
52 #include <babeltrace/endian-internal.h>
53 #include <inttypes.h>
54 #include <stdint.h>
55 #include <string.h>
56 #include <stdlib.h>
57
58 #define DEFAULT_IDENTIFIER_SIZE 128
59 #define DEFAULT_METADATA_STRING_SIZE 4096
60
61 struct listener_wrapper {
62 bt_listener_cb listener;
63 void *data;
64 };
65
66 struct bt_trace_is_static_listener_elem {
67 bt_trace_is_static_listener func;
68 bt_trace_listener_removed removed;
69 void *data;
70 };
71
72 static
73 void bt_trace_destroy(struct bt_object *obj);
74 static
75 void bt_trace_freeze(struct bt_trace *trace);
76
77 static
78 const unsigned int field_type_aliases_alignments[] = {
79 [FIELD_TYPE_ALIAS_UINT5_T] = 1,
80 [FIELD_TYPE_ALIAS_UINT8_T ... FIELD_TYPE_ALIAS_UINT16_T] = 8,
81 [FIELD_TYPE_ALIAS_UINT27_T] = 1,
82 [FIELD_TYPE_ALIAS_UINT32_T ... FIELD_TYPE_ALIAS_UINT64_T] = 8,
83 };
84
85 static
86 const unsigned int field_type_aliases_sizes[] = {
87 [FIELD_TYPE_ALIAS_UINT5_T] = 5,
88 [FIELD_TYPE_ALIAS_UINT8_T] = 8,
89 [FIELD_TYPE_ALIAS_UINT16_T] = 16,
90 [FIELD_TYPE_ALIAS_UINT27_T] = 27,
91 [FIELD_TYPE_ALIAS_UINT32_T] = 32,
92 [FIELD_TYPE_ALIAS_UINT64_T] = 64,
93 };
94
95 struct bt_trace *bt_trace_create(void)
96 {
97 struct bt_trace *trace = NULL;
98
99 trace = g_new0(struct bt_trace, 1);
100 if (!trace) {
101 BT_LOGE_STR("Failed to allocate one trace.");
102 goto error;
103 }
104
105 BT_LOGD_STR("Creating trace object.");
106 trace->native_byte_order = BT_BYTE_ORDER_UNSPECIFIED;
107 bt_object_init(trace, bt_trace_destroy);
108 trace->clocks = g_ptr_array_new_with_free_func(
109 (GDestroyNotify) bt_put);
110 if (!trace->clocks) {
111 BT_LOGE_STR("Failed to allocate one GPtrArray.");
112 goto error;
113 }
114
115 trace->streams = g_ptr_array_new_with_free_func(
116 (GDestroyNotify) bt_object_release);
117 if (!trace->streams) {
118 BT_LOGE_STR("Failed to allocate one GPtrArray.");
119 goto error;
120 }
121
122 trace->stream_classes = g_ptr_array_new_with_free_func(
123 (GDestroyNotify) bt_object_release);
124 if (!trace->stream_classes) {
125 BT_LOGE_STR("Failed to allocate one GPtrArray.");
126 goto error;
127 }
128
129 /* Create the environment array object */
130 trace->environment = bt_attributes_create();
131 if (!trace->environment) {
132 BT_LOGE_STR("Cannot create empty attributes object.");
133 goto error;
134 }
135
136 trace->listeners = g_ptr_array_new_with_free_func(
137 (GDestroyNotify) g_free);
138 if (!trace->listeners) {
139 BT_LOGE_STR("Failed to allocate one GPtrArray.");
140 goto error;
141 }
142
143 trace->is_static_listeners = g_array_new(FALSE, TRUE,
144 sizeof(struct bt_trace_is_static_listener_elem));
145 if (!trace->is_static_listeners) {
146 BT_LOGE_STR("Failed to allocate one GArray.");
147 goto error;
148 }
149
150 BT_LOGD("Created trace object: addr=%p", trace);
151 return trace;
152
153 error:
154 BT_PUT(trace);
155 return trace;
156 }
157
158 const char *bt_trace_get_name(struct bt_trace *trace)
159 {
160 const char *name = NULL;
161
162 if (!trace) {
163 BT_LOGW_STR("Invalid parameter: trace is NULL.");
164 goto end;
165 }
166
167 if (!trace->name) {
168 goto end;
169 }
170
171 name = trace->name->str;
172 end:
173 return name;
174 }
175
176 int bt_trace_set_name(struct bt_trace *trace, const char *name)
177 {
178 int ret = 0;
179
180 if (!trace) {
181 BT_LOGW_STR("Invalid parameter: trace is NULL.");
182 ret = -1;
183 goto end;
184 }
185
186 if (!name) {
187 BT_LOGW_STR("Invalid parameter: name is NULL.");
188 ret = -1;
189 goto end;
190 }
191
192 if (trace->frozen) {
193 BT_LOGW("Invalid parameter: trace is frozen: "
194 "addr=%p, name=\"%s\"",
195 trace, bt_trace_get_name(trace));
196 ret = -1;
197 goto end;
198 }
199
200 trace->name = trace->name ? g_string_assign(trace->name, name) :
201 g_string_new(name);
202 if (!trace->name) {
203 BT_LOGE_STR("Failed to allocate one GString.");
204 ret = -1;
205 goto end;
206 }
207
208 BT_LOGV("Set trace's name: addr=%p, name=\"%s\"", trace, name);
209
210 end:
211 return ret;
212 }
213
214 const unsigned char *bt_trace_get_uuid(struct bt_trace *trace)
215 {
216 return trace && trace->uuid_set ? trace->uuid : NULL;
217 }
218
219 int bt_trace_set_uuid(struct bt_trace *trace, const unsigned char *uuid)
220 {
221 int ret = 0;
222
223 if (!trace) {
224 BT_LOGW_STR("Invalid parameter: trace is NULL.");
225 ret = -1;
226 goto end;
227 }
228
229 if (!uuid) {
230 BT_LOGW_STR("Invalid parameter: UUID is NULL.");
231 ret = -1;
232 goto end;
233 }
234
235 if (trace->frozen) {
236 BT_LOGW("Invalid parameter: trace is frozen: "
237 "addr=%p, name=\"%s\"",
238 trace, bt_trace_get_name(trace));
239 ret = -1;
240 goto end;
241 }
242
243 memcpy(trace->uuid, uuid, BABELTRACE_UUID_LEN);
244 trace->uuid_set = BT_TRUE;
245 BT_LOGV("Set trace's UUID: addr=%p, name=\"%s\", "
246 "uuid=\"%02x%02x%02x%02x-%02x%02x-%02x%02x-%02x%02x-%02x%02x%02x%02x%02x%02x\"",
247 trace, bt_trace_get_name(trace),
248 (unsigned int) uuid[0],
249 (unsigned int) uuid[1],
250 (unsigned int) uuid[2],
251 (unsigned int) uuid[3],
252 (unsigned int) uuid[4],
253 (unsigned int) uuid[5],
254 (unsigned int) uuid[6],
255 (unsigned int) uuid[7],
256 (unsigned int) uuid[8],
257 (unsigned int) uuid[9],
258 (unsigned int) uuid[10],
259 (unsigned int) uuid[11],
260 (unsigned int) uuid[12],
261 (unsigned int) uuid[13],
262 (unsigned int) uuid[14],
263 (unsigned int) uuid[15]);
264
265 end:
266 return ret;
267 }
268
269 void bt_trace_destroy(struct bt_object *obj)
270 {
271 struct bt_trace *trace;
272
273 trace = container_of(obj, struct bt_trace, base);
274
275 BT_LOGD("Destroying trace object: addr=%p, name=\"%s\"",
276 trace, bt_trace_get_name(trace));
277
278 /*
279 * Call remove listeners first so that everything else still
280 * exists in the trace.
281 */
282 if (trace->is_static_listeners) {
283 size_t i;
284
285 for (i = 0; i < trace->is_static_listeners->len; i++) {
286 struct bt_trace_is_static_listener_elem elem =
287 g_array_index(trace->is_static_listeners,
288 struct bt_trace_is_static_listener_elem, i);
289
290 if (elem.removed) {
291 elem.removed(trace, elem.data);
292 }
293 }
294
295 g_array_free(trace->is_static_listeners, TRUE);
296 }
297
298 if (trace->listeners) {
299 g_ptr_array_free(trace->listeners, TRUE);
300 }
301
302 if (trace->environment) {
303 BT_LOGD_STR("Destroying environment attributes.");
304 bt_attributes_destroy(trace->environment);
305 }
306
307 if (trace->name) {
308 g_string_free(trace->name, TRUE);
309 }
310
311 if (trace->clocks) {
312 BT_LOGD_STR("Putting clock classes.");
313 g_ptr_array_free(trace->clocks, TRUE);
314 }
315
316 if (trace->streams) {
317 BT_LOGD_STR("Destroying streams.");
318 g_ptr_array_free(trace->streams, TRUE);
319 }
320
321 if (trace->stream_classes) {
322 BT_LOGD_STR("Destroying stream classes.");
323 g_ptr_array_free(trace->stream_classes, TRUE);
324 }
325
326 BT_LOGD_STR("Putting packet header field type.");
327 bt_put(trace->packet_header_type);
328 g_free(trace);
329 }
330
331 int bt_trace_set_environment_field(struct bt_trace *trace,
332 const char *name, struct bt_value *value)
333 {
334 int ret = 0;
335
336 if (!trace) {
337 BT_LOGW_STR("Invalid parameter: trace is NULL.");
338 ret = -1;
339 goto end;
340 }
341
342 if (!name) {
343 BT_LOGW_STR("Invalid parameter: name is NULL.");
344 ret = -1;
345 goto end;
346 }
347
348 if (!value) {
349 BT_LOGW_STR("Invalid parameter: value is NULL.");
350 ret = -1;
351 goto end;
352 }
353
354 if (!bt_identifier_is_valid(name)) {
355 BT_LOGW("Invalid parameter: environment field's name is not a valid CTF identifier: "
356 "trace-addr=%p, trace-name=\"%s\", "
357 "env-name=\"%s\"",
358 trace, bt_trace_get_name(trace), name);
359 ret = -1;
360 goto end;
361 }
362
363 if (!bt_value_is_integer(value) && !bt_value_is_string(value)) {
364 BT_LOGW("Invalid parameter: environment field's value is not an integer or string value: "
365 "trace-addr=%p, trace-name=\"%s\", "
366 "env-name=\"%s\", env-value-type=%s",
367 trace, bt_trace_get_name(trace), name,
368 bt_value_type_string(bt_value_get_type(value)));
369 ret = -1;
370 goto end;
371 }
372
373 if (trace->is_static) {
374 BT_LOGW("Invalid parameter: trace is static: "
375 "addr=%p, name=\"%s\"",
376 trace, bt_trace_get_name(trace));
377 ret = -1;
378 goto end;
379 }
380
381 if (trace->frozen) {
382 /*
383 * New environment fields may be added to a frozen trace,
384 * but existing fields may not be changed.
385 *
386 * The object passed is frozen like all other attributes.
387 */
388 struct bt_value *attribute =
389 bt_attributes_get_field_value_by_name(
390 trace->environment, name);
391
392 if (attribute) {
393 BT_LOGW("Invalid parameter: trace is frozen and environment field already exists with this name: "
394 "trace-addr=%p, trace-name=\"%s\", "
395 "env-name=\"%s\"",
396 trace, bt_trace_get_name(trace), name);
397 BT_PUT(attribute);
398 ret = -1;
399 goto end;
400 }
401
402 bt_value_freeze(value);
403 }
404
405 ret = bt_attributes_set_field_value(trace->environment, name,
406 value);
407 if (ret) {
408 BT_LOGE("Cannot set environment field's value: "
409 "trace-addr=%p, trace-name=\"%s\", "
410 "env-name=\"%s\"",
411 trace, bt_trace_get_name(trace), name);
412 } else {
413 BT_LOGV("Set environment field's value: "
414 "trace-addr=%p, trace-name=\"%s\", "
415 "env-name=\"%s\", value-addr=%p",
416 trace, bt_trace_get_name(trace), name, value);
417 }
418
419 end:
420 return ret;
421 }
422
423 int bt_trace_set_environment_field_string(struct bt_trace *trace,
424 const char *name, const char *value)
425 {
426 int ret = 0;
427 struct bt_value *env_value_string_obj = NULL;
428
429 if (!value) {
430 BT_LOGW_STR("Invalid parameter: value is NULL.");
431 ret = -1;
432 goto end;
433 }
434
435 env_value_string_obj = bt_value_string_create_init(value);
436 if (!env_value_string_obj) {
437 BT_LOGE_STR("Cannot create string value object.");
438 ret = -1;
439 goto end;
440 }
441
442 /* bt_trace_set_environment_field() logs errors */
443 ret = bt_trace_set_environment_field(trace, name,
444 env_value_string_obj);
445
446 end:
447 bt_put(env_value_string_obj);
448 return ret;
449 }
450
451 int bt_trace_set_environment_field_integer(struct bt_trace *trace,
452 const char *name, int64_t value)
453 {
454 int ret = 0;
455 struct bt_value *env_value_integer_obj = NULL;
456
457 env_value_integer_obj = bt_value_integer_create_init(value);
458 if (!env_value_integer_obj) {
459 BT_LOGE_STR("Cannot create integer value object.");
460 ret = -1;
461 goto end;
462 }
463
464 /* bt_trace_set_environment_field() logs errors */
465 ret = bt_trace_set_environment_field(trace, name,
466 env_value_integer_obj);
467
468 end:
469 bt_put(env_value_integer_obj);
470 return ret;
471 }
472
473 int64_t bt_trace_get_environment_field_count(struct bt_trace *trace)
474 {
475 int64_t ret = 0;
476
477 if (!trace) {
478 BT_LOGW_STR("Invalid parameter: trace is NULL.");
479 ret = (int64_t) -1;
480 goto end;
481 }
482
483 ret = bt_attributes_get_count(trace->environment);
484 assert(ret >= 0);
485
486 end:
487 return ret;
488 }
489
490 const char *
491 bt_trace_get_environment_field_name_by_index(struct bt_trace *trace,
492 uint64_t index)
493 {
494 const char *ret = NULL;
495
496 if (!trace) {
497 BT_LOGW_STR("Invalid parameter: trace is NULL.");
498 goto end;
499 }
500
501 ret = bt_attributes_get_field_name(trace->environment, index);
502
503 end:
504 return ret;
505 }
506
507 struct bt_value *bt_trace_get_environment_field_value_by_index(
508 struct bt_trace *trace, uint64_t index)
509 {
510 struct bt_value *ret = NULL;
511
512 if (!trace) {
513 BT_LOGW_STR("Invalid parameter: trace is NULL.");
514 goto end;
515 }
516
517 ret = bt_attributes_get_field_value(trace->environment, index);
518
519 end:
520 return ret;
521 }
522
523 struct bt_value *bt_trace_get_environment_field_value_by_name(
524 struct bt_trace *trace, const char *name)
525 {
526 struct bt_value *ret = NULL;
527
528 if (!trace) {
529 BT_LOGW_STR("Invalid parameter: trace is NULL.");
530 goto end;
531 }
532
533 if (!name) {
534 BT_LOGW_STR("Invalid parameter: name is NULL.");
535 goto end;
536 }
537
538 ret = bt_attributes_get_field_value_by_name(trace->environment,
539 name);
540
541 end:
542 return ret;
543 }
544
545 int bt_trace_add_clock_class(struct bt_trace *trace,
546 struct bt_clock_class *clock_class)
547 {
548 int ret = 0;
549
550 if (!trace) {
551 BT_LOGW_STR("Invalid parameter: trace is NULL.");
552 ret = -1;
553 goto end;
554 }
555
556 if (trace->is_static) {
557 BT_LOGW("Invalid parameter: trace is static: "
558 "addr=%p, name=\"%s\"",
559 trace, bt_trace_get_name(trace));
560 ret = -1;
561 goto end;
562 }
563
564 if (!bt_clock_class_is_valid(clock_class)) {
565 BT_LOGW("Invalid parameter: clock class is invalid: "
566 "trace-addr=%p, trace-name=\"%s\", "
567 "clock-class-addr=%p, clock-class-name=\"%s\"",
568 trace, bt_trace_get_name(trace),
569 clock_class, bt_clock_class_get_name(clock_class));
570 ret = -1;
571 goto end;
572 }
573
574 /* Check for duplicate clock classes */
575 if (bt_trace_has_clock_class(trace, clock_class)) {
576 BT_LOGW("Invalid parameter: clock class already exists in trace: "
577 "trace-addr=%p, trace-name=\"%s\", "
578 "clock-class-addr=%p, clock-class-name=\"%s\"",
579 trace, bt_trace_get_name(trace),
580 clock_class, bt_clock_class_get_name(clock_class));
581 ret = -1;
582 goto end;
583 }
584
585 bt_get(clock_class);
586 g_ptr_array_add(trace->clocks, clock_class);
587
588 if (trace->frozen) {
589 BT_LOGV_STR("Freezing added clock class because trace is frozen.");
590 bt_clock_class_freeze(clock_class);
591 }
592
593 BT_LOGV("Added clock class to trace: "
594 "trace-addr=%p, trace-name=\"%s\", "
595 "clock-class-addr=%p, clock-class-name=\"%s\"",
596 trace, bt_trace_get_name(trace),
597 clock_class, bt_clock_class_get_name(clock_class));
598
599 end:
600 return ret;
601 }
602
603 int64_t bt_trace_get_clock_class_count(struct bt_trace *trace)
604 {
605 int64_t ret = (int64_t) -1;
606
607 if (!trace) {
608 BT_LOGW_STR("Invalid parameter: trace is NULL.");
609 goto end;
610 }
611
612 ret = trace->clocks->len;
613 end:
614 return ret;
615 }
616
617 struct bt_clock_class *bt_trace_get_clock_class_by_index(
618 struct bt_trace *trace, uint64_t index)
619 {
620 struct bt_clock_class *clock_class = NULL;
621
622 if (!trace) {
623 BT_LOGW_STR("Invalid parameter: trace is NULL.");
624 goto end;
625 }
626
627 if (index >= trace->clocks->len) {
628 BT_LOGW("Invalid parameter: index is out of bounds: "
629 "addr=%p, name=\"%s\", "
630 "index=%" PRIu64 ", count=%u",
631 trace, bt_trace_get_name(trace),
632 index, trace->clocks->len);
633 goto end;
634 }
635
636 clock_class = g_ptr_array_index(trace->clocks, index);
637 bt_get(clock_class);
638 end:
639 return clock_class;
640 }
641
642 static
643 bool packet_header_field_type_is_valid(struct bt_trace *trace,
644 struct bt_field_type *packet_header_type)
645 {
646 int ret;
647 bool is_valid = true;
648 struct bt_field_type *field_type = NULL;
649
650 if (!packet_header_type) {
651 /*
652 * No packet header field type: trace must have only
653 * one stream. At this point the stream class being
654 * added is not part of the trace yet, so we validate
655 * that the trace contains no stream classes yet.
656 */
657 if (trace->stream_classes->len >= 1) {
658 BT_LOGW_STR("Invalid packet header field type: "
659 "packet header field type does not exist but there's more than one stream class in the trace.");
660 goto invalid;
661 }
662
663 /* No packet header field type: valid at this point */
664 goto end;
665 }
666
667 /* Packet header field type, if it exists, must be a structure */
668 if (!bt_field_type_is_structure(packet_header_type)) {
669 BT_LOGW("Invalid packet header field type: must be a structure field type if it exists: "
670 "ft-addr=%p, ft-id=%s",
671 packet_header_type,
672 bt_field_type_id_string(packet_header_type->id));
673 goto invalid;
674 }
675
676 /*
677 * If there's a `magic` field, it must be a 32-bit unsigned
678 * integer field type. Also it must be the first field of the
679 * packet header field type.
680 */
681 field_type = bt_field_type_structure_get_field_type_by_name(
682 packet_header_type, "magic");
683 if (field_type) {
684 const char *field_name;
685
686 if (!bt_field_type_is_integer(field_type)) {
687 BT_LOGW("Invalid packet header field type: `magic` field must be an integer field type: "
688 "magic-ft-addr=%p, magic-ft-id=%s",
689 field_type,
690 bt_field_type_id_string(field_type->id));
691 goto invalid;
692 }
693
694 if (bt_field_type_integer_is_signed(field_type)) {
695 BT_LOGW("Invalid packet header field type: `magic` field must be an unsigned integer field type: "
696 "magic-ft-addr=%p", field_type);
697 goto invalid;
698 }
699
700 if (bt_field_type_integer_get_size(field_type) != 32) {
701 BT_LOGW("Invalid packet header field type: `magic` field must be a 32-bit unsigned integer field type: "
702 "magic-ft-addr=%p, magic-ft-size=%u",
703 field_type,
704 bt_field_type_integer_get_size(field_type));
705 goto invalid;
706 }
707
708 ret = bt_field_type_structure_get_field_by_index(
709 packet_header_type, &field_name, NULL, 0);
710 assert(ret == 0);
711
712 if (strcmp(field_name, "magic") != 0) {
713 BT_LOGW("Invalid packet header field type: `magic` field must be the first field: "
714 "magic-ft-addr=%p, first-field-name=\"%s\"",
715 field_type, field_name);
716 goto invalid;
717 }
718
719 BT_PUT(field_type);
720 }
721
722 /*
723 * If there's a `uuid` field, it must be an array field type of
724 * length 16 with an 8-bit unsigned integer element field type.
725 */
726 field_type = bt_field_type_structure_get_field_type_by_name(
727 packet_header_type, "uuid");
728 if (field_type) {
729 struct bt_field_type *elem_ft;
730
731 if (!bt_field_type_is_array(field_type)) {
732 BT_LOGW("Invalid packet header field type: `uuid` field must be an array field type: "
733 "uuid-ft-addr=%p, uuid-ft-id=%s",
734 field_type,
735 bt_field_type_id_string(field_type->id));
736 goto invalid;
737 }
738
739 if (bt_field_type_array_get_length(field_type) != 16) {
740 BT_LOGW("Invalid packet header field type: `uuid` array field type's length must be 16: "
741 "uuid-ft-addr=%p, uuid-ft-length=%" PRId64,
742 field_type,
743 bt_field_type_array_get_length(field_type));
744 goto invalid;
745 }
746
747 elem_ft = bt_field_type_array_get_element_type(field_type);
748 assert(elem_ft);
749
750 if (!bt_field_type_is_integer(elem_ft)) {
751 BT_LOGW("Invalid packet header field type: `uuid` field's element field type must be an integer field type: "
752 "elem-ft-addr=%p, elem-ft-id=%s",
753 elem_ft,
754 bt_field_type_id_string(elem_ft->id));
755 bt_put(elem_ft);
756 goto invalid;
757 }
758
759 if (bt_field_type_integer_is_signed(elem_ft)) {
760 BT_LOGW("Invalid packet header field type: `uuid` field's element field type must be an unsigned integer field type: "
761 "elem-ft-addr=%p", elem_ft);
762 bt_put(elem_ft);
763 goto invalid;
764 }
765
766 if (bt_field_type_integer_get_size(elem_ft) != 8) {
767 BT_LOGW("Invalid packet header field type: `uuid` field's element field type must be an 8-bit unsigned integer field type: "
768 "elem-ft-addr=%p, elem-ft-size=%u",
769 elem_ft,
770 bt_field_type_integer_get_size(elem_ft));
771 bt_put(elem_ft);
772 goto invalid;
773 }
774
775 bt_put(elem_ft);
776 BT_PUT(field_type);
777 }
778
779 /*
780 * The `stream_id` field must exist if there's more than one
781 * stream classes in the trace.
782 */
783 field_type = bt_field_type_structure_get_field_type_by_name(
784 packet_header_type, "stream_id");
785
786 if (!field_type && trace->stream_classes->len >= 1) {
787 BT_LOGW_STR("Invalid packet header field type: "
788 "`stream_id` field does not exist but there's more than one stream class in the trace.");
789 goto invalid;
790 }
791
792 /*
793 * If there's a `stream_id` field, it must be an unsigned
794 * integer field type.
795 */
796 if (field_type) {
797 if (!bt_field_type_is_integer(field_type)) {
798 BT_LOGW("Invalid packet header field type: `stream_id` field must be an integer field type: "
799 "stream-id-ft-addr=%p, stream-id-ft-id=%s",
800 field_type,
801 bt_field_type_id_string(field_type->id));
802 goto invalid;
803 }
804
805 if (bt_field_type_integer_is_signed(field_type)) {
806 BT_LOGW("Invalid packet header field type: `stream_id` field must be an unsigned integer field type: "
807 "stream-id-ft-addr=%p", field_type);
808 goto invalid;
809 }
810
811 BT_PUT(field_type);
812 }
813
814 /*
815 * If there's a `packet_seq_num` field, it must be an unsigned
816 * integer field type.
817 */
818 field_type = bt_field_type_structure_get_field_type_by_name(
819 packet_header_type, "packet_seq_num");
820 if (field_type) {
821 if (!bt_field_type_is_integer(field_type)) {
822 BT_LOGW("Invalid packet header field type: `packet_seq_num` field must be an integer field type: "
823 "stream-id-ft-addr=%p, packet-seq-num-ft-id=%s",
824 field_type,
825 bt_field_type_id_string(field_type->id));
826 goto invalid;
827 }
828
829 if (bt_field_type_integer_is_signed(field_type)) {
830 BT_LOGW("Invalid packet header field type: `packet_seq_num` field must be an unsigned integer field type: "
831 "packet-seq-num-ft-addr=%p", field_type);
832 goto invalid;
833 }
834
835 BT_PUT(field_type);
836 }
837
838 goto end;
839
840 invalid:
841 is_valid = false;
842
843 end:
844 bt_put(field_type);
845 return is_valid;
846 }
847
848 static
849 bool packet_context_field_type_is_valid(struct bt_trace *trace,
850 struct bt_stream_class *stream_class,
851 struct bt_field_type *packet_context_type)
852 {
853 bool is_valid = true;
854 struct bt_field_type *field_type = NULL;
855
856 if (!packet_context_type) {
857 /* No packet context field type: valid at this point */
858 goto end;
859 }
860
861 /* Packet context field type, if it exists, must be a structure */
862 if (!bt_field_type_is_structure(packet_context_type)) {
863 BT_LOGW("Invalid packet context field type: must be a structure field type if it exists: "
864 "ft-addr=%p, ft-id=%s",
865 packet_context_type,
866 bt_field_type_id_string(packet_context_type->id));
867 goto invalid;
868 }
869
870 /*
871 * If there's a `packet_size` field, it must be an unsigned
872 * integer field type.
873 */
874 field_type = bt_field_type_structure_get_field_type_by_name(
875 packet_context_type, "packet_size");
876 if (field_type) {
877 if (!bt_field_type_is_integer(field_type)) {
878 BT_LOGW("Invalid packet context field type: `packet_size` field must be an integer field type: "
879 "packet-size-ft-addr=%p, packet-size-ft-id=%s",
880 field_type,
881 bt_field_type_id_string(field_type->id));
882 goto invalid;
883 }
884
885 if (bt_field_type_integer_is_signed(field_type)) {
886 BT_LOGW("Invalid packet context field type: `packet_size` field must be an unsigned integer field type: "
887 "packet-size-ft-addr=%p", field_type);
888 goto invalid;
889 }
890
891 BT_PUT(field_type);
892 }
893
894 /*
895 * If there's a `content_size` field, it must be an unsigned
896 * integer field type.
897 */
898 field_type = bt_field_type_structure_get_field_type_by_name(
899 packet_context_type, "content_size");
900 if (field_type) {
901 if (!bt_field_type_is_integer(field_type)) {
902 BT_LOGW("Invalid packet context field type: `content_size` field must be an integer field type: "
903 "content-size-ft-addr=%p, content-size-ft-id=%s",
904 field_type,
905 bt_field_type_id_string(field_type->id));
906 goto invalid;
907 }
908
909 if (bt_field_type_integer_is_signed(field_type)) {
910 BT_LOGW("Invalid packet context field type: `content_size` field must be an unsigned integer field type: "
911 "content-size-ft-addr=%p", field_type);
912 goto invalid;
913 }
914
915 BT_PUT(field_type);
916 }
917
918 /*
919 * If there's a `events_discarded` field, it must be an unsigned
920 * integer field type.
921 */
922 field_type = bt_field_type_structure_get_field_type_by_name(
923 packet_context_type, "events_discarded");
924 if (field_type) {
925 if (!bt_field_type_is_integer(field_type)) {
926 BT_LOGW("Invalid packet context field type: `events_discarded` field must be an integer field type: "
927 "events-discarded-ft-addr=%p, events-discarded-ft-id=%s",
928 field_type,
929 bt_field_type_id_string(field_type->id));
930 goto invalid;
931 }
932
933 if (bt_field_type_integer_is_signed(field_type)) {
934 BT_LOGW("Invalid packet context field type: `events_discarded` field must be an unsigned integer field type: "
935 "events-discarded-ft-addr=%p", field_type);
936 goto invalid;
937 }
938
939 BT_PUT(field_type);
940 }
941
942 /*
943 * If there's a `timestamp_begin` field, it must be an unsigned
944 * integer field type. Also, if the trace is not a CTF writer's
945 * trace, then we cannot automatically set the mapped clock
946 * class of this field, so it must have a mapped clock class.
947 */
948 field_type = bt_field_type_structure_get_field_type_by_name(
949 packet_context_type, "timestamp_begin");
950 if (field_type) {
951 if (!bt_field_type_is_integer(field_type)) {
952 BT_LOGW("Invalid packet context field type: `timestamp_begin` field must be an integer field type: "
953 "timestamp-begin-ft-addr=%p, timestamp-begin-ft-id=%s",
954 field_type,
955 bt_field_type_id_string(field_type->id));
956 goto invalid;
957 }
958
959 if (bt_field_type_integer_is_signed(field_type)) {
960 BT_LOGW("Invalid packet context field type: `timestamp_begin` field must be an unsigned integer field type: "
961 "timestamp-begin-ft-addr=%p", field_type);
962 goto invalid;
963 }
964
965 if (!trace->is_created_by_writer) {
966 struct bt_clock_class *clock_class =
967 bt_field_type_integer_get_mapped_clock_class(
968 field_type);
969
970 bt_put(clock_class);
971 if (!clock_class) {
972 BT_LOGW("Invalid packet context field type: `timestamp_begin` field must be mapped to a clock class: "
973 "timestamp-begin-ft-addr=%p", field_type);
974 goto invalid;
975 }
976 }
977
978 BT_PUT(field_type);
979 }
980
981 /*
982 * If there's a `timestamp_end` field, it must be an unsigned
983 * integer field type. Also, if the trace is not a CTF writer's
984 * trace, then we cannot automatically set the mapped clock
985 * class of this field, so it must have a mapped clock class.
986 */
987 field_type = bt_field_type_structure_get_field_type_by_name(
988 packet_context_type, "timestamp_end");
989 if (field_type) {
990 if (!bt_field_type_is_integer(field_type)) {
991 BT_LOGW("Invalid packet context field type: `timestamp_end` field must be an integer field type: "
992 "timestamp-end-ft-addr=%p, timestamp-end-ft-id=%s",
993 field_type,
994 bt_field_type_id_string(field_type->id));
995 goto invalid;
996 }
997
998 if (bt_field_type_integer_is_signed(field_type)) {
999 BT_LOGW("Invalid packet context field type: `timestamp_end` field must be an unsigned integer field type: "
1000 "timestamp-end-ft-addr=%p", field_type);
1001 goto invalid;
1002 }
1003
1004 if (!trace->is_created_by_writer) {
1005 struct bt_clock_class *clock_class =
1006 bt_field_type_integer_get_mapped_clock_class(
1007 field_type);
1008
1009 bt_put(clock_class);
1010 if (!clock_class) {
1011 BT_LOGW("Invalid packet context field type: `timestamp_end` field must be mapped to a clock class: "
1012 "timestamp-end-ft-addr=%p", field_type);
1013 goto invalid;
1014 }
1015 }
1016
1017 BT_PUT(field_type);
1018 }
1019
1020 goto end;
1021
1022 invalid:
1023 is_valid = false;
1024
1025 end:
1026 bt_put(field_type);
1027 return is_valid;
1028 }
1029
1030 static
1031 bool event_header_field_type_is_valid(struct bt_trace *trace,
1032 struct bt_stream_class *stream_class,
1033 struct bt_field_type *event_header_type)
1034 {
1035 bool is_valid = true;
1036 struct bt_field_type *field_type = NULL;
1037
1038 /*
1039 * We do not validate that the `timestamp` field exists here
1040 * because CTF does not require this exact name to be mapped to
1041 * a clock class.
1042 */
1043
1044 if (!event_header_type) {
1045 /*
1046 * No event header field type: stream class must have
1047 * only one event class.
1048 */
1049 if (bt_stream_class_get_event_class_count(stream_class) > 1) {
1050 BT_LOGW_STR("Invalid event header field type: "
1051 "event header field type does not exist but there's more than one event class in the stream class.");
1052 goto invalid;
1053 }
1054
1055 /* No event header field type: valid at this point */
1056 goto end;
1057 }
1058
1059 /* Event header field type, if it exists, must be a structure */
1060 if (!bt_field_type_is_structure(event_header_type)) {
1061 BT_LOGW("Invalid event header field type: must be a structure field type if it exists: "
1062 "ft-addr=%p, ft-id=%s",
1063 event_header_type,
1064 bt_field_type_id_string(event_header_type->id));
1065 goto invalid;
1066 }
1067
1068 /*
1069 * If there's an `id` field, it must be an unsigned integer
1070 * field type or an enumeration field type with an unsigned
1071 * integer container field type.
1072 */
1073 field_type = bt_field_type_structure_get_field_type_by_name(
1074 event_header_type, "id");
1075 if (field_type) {
1076 struct bt_field_type *int_ft;
1077
1078 if (bt_field_type_is_integer(field_type)) {
1079 int_ft = bt_get(field_type);
1080 } else if (bt_field_type_is_enumeration(field_type)) {
1081 int_ft = bt_field_type_enumeration_get_container_type(
1082 field_type);
1083 } else {
1084 BT_LOGW("Invalid event header field type: `id` field must be an integer or enumeration field type: "
1085 "id-ft-addr=%p, id-ft-id=%s",
1086 field_type,
1087 bt_field_type_id_string(field_type->id));
1088 goto invalid;
1089 }
1090
1091 assert(int_ft);
1092 if (bt_field_type_integer_is_signed(int_ft)) {
1093 BT_LOGW("Invalid event header field type: `id` field must be an unsigned integer or enumeration field type: "
1094 "id-ft-addr=%p", int_ft);
1095 goto invalid;
1096 }
1097
1098 bt_put(int_ft);
1099 BT_PUT(field_type);
1100 }
1101
1102 goto end;
1103
1104 invalid:
1105 is_valid = false;
1106
1107 end:
1108 bt_put(field_type);
1109 return is_valid;
1110 }
1111
1112 static
1113 int check_packet_header_type_has_no_clock_class(struct bt_trace *trace)
1114 {
1115 int ret = 0;
1116
1117 if (trace->packet_header_type) {
1118 struct bt_clock_class *clock_class = NULL;
1119
1120 ret = bt_validate_single_clock_class(trace->packet_header_type,
1121 &clock_class);
1122 bt_put(clock_class);
1123 if (ret || clock_class) {
1124 BT_LOGW("Trace's packet header field type cannot "
1125 "contain a field type which is mapped to "
1126 "a clock class: "
1127 "trace-addr=%p, trace-name=\"%s\", "
1128 "clock-class-name=\"%s\"",
1129 trace, bt_trace_get_name(trace),
1130 clock_class ?
1131 bt_clock_class_get_name(clock_class) :
1132 NULL);
1133 ret = -1;
1134 }
1135 }
1136
1137 return ret;
1138 }
1139
1140 int bt_trace_add_stream_class(struct bt_trace *trace,
1141 struct bt_stream_class *stream_class)
1142 {
1143 int ret;
1144 int64_t i;
1145 int64_t stream_id;
1146 struct bt_validation_output trace_sc_validation_output = { 0 };
1147 struct bt_validation_output *ec_validation_outputs = NULL;
1148 const enum bt_validation_flag trace_sc_validation_flags =
1149 BT_VALIDATION_FLAG_TRACE |
1150 BT_VALIDATION_FLAG_STREAM;
1151 const enum bt_validation_flag ec_validation_flags =
1152 BT_VALIDATION_FLAG_EVENT;
1153 struct bt_field_type *packet_header_type = NULL;
1154 struct bt_field_type *packet_context_type = NULL;
1155 struct bt_field_type *event_header_type = NULL;
1156 struct bt_field_type *stream_event_ctx_type = NULL;
1157 int64_t event_class_count;
1158 struct bt_trace *current_parent_trace = NULL;
1159 struct bt_clock_class *expected_clock_class = NULL;
1160
1161 if (!trace) {
1162 BT_LOGW_STR("Invalid parameter: trace is NULL.");
1163 ret = -1;
1164 goto end;
1165 }
1166
1167 if (!stream_class) {
1168 BT_LOGW_STR("Invalid parameter: stream class is NULL.");
1169 ret = -1;
1170 goto end;
1171 }
1172
1173 if (trace->is_static) {
1174 BT_LOGW_STR("Invalid parameter: trace is static.");
1175 ret = -1;
1176 goto end;
1177 }
1178
1179 BT_LOGD("Adding stream class to trace: "
1180 "trace-addr=%p, trace-name=\"%s\", "
1181 "stream-class-addr=%p, stream-class-name=\"%s\", "
1182 "stream-class-id=%" PRId64,
1183 trace, bt_trace_get_name(trace),
1184 stream_class, bt_stream_class_get_name(stream_class),
1185 bt_stream_class_get_id(stream_class));
1186
1187 current_parent_trace = bt_stream_class_get_trace(stream_class);
1188 if (current_parent_trace) {
1189 /* Stream class is already associated to a trace, abort. */
1190 BT_LOGW("Invalid parameter: stream class is already part of a trace: "
1191 "stream-class-trace-addr=%p, "
1192 "stream-class-trace-name=\"%s\"",
1193 current_parent_trace,
1194 bt_trace_get_name(current_parent_trace));
1195 ret = -1;
1196 goto end;
1197 }
1198
1199 event_class_count =
1200 bt_stream_class_get_event_class_count(stream_class);
1201 assert(event_class_count >= 0);
1202
1203 if (stream_class->clock) {
1204 struct bt_clock_class *stream_clock_class =
1205 stream_class->clock->clock_class;
1206
1207 if (trace->is_created_by_writer) {
1208 /*
1209 * Make sure this clock was also added to the
1210 * trace (potentially through its CTF writer
1211 * owner).
1212 */
1213 size_t i;
1214
1215 for (i = 0; i < trace->clocks->len; i++) {
1216 if (trace->clocks->pdata[i] ==
1217 stream_clock_class) {
1218 /* Found! */
1219 break;
1220 }
1221 }
1222
1223 if (i == trace->clocks->len) {
1224 /* Not found */
1225 BT_LOGW("Stream class's clock's class is not part of the trace: "
1226 "clock-class-addr=%p, clock-class-name=\"%s\"",
1227 stream_clock_class,
1228 bt_clock_class_get_name(stream_clock_class));
1229 ret = -1;
1230 goto end;
1231 }
1232 } else {
1233 /*
1234 * This trace was NOT created by a CTF writer,
1235 * thus do not allow the stream class to add to
1236 * have a clock at all. Those are two
1237 * independent APIs (non-writer and writer
1238 * APIs), and isolating them simplifies things.
1239 */
1240 BT_LOGW("Cannot add stream class with a clock to a trace which was not created by a CTF writer object: "
1241 "clock-class-addr=%p, clock-class-name=\"%s\"",
1242 stream_clock_class,
1243 bt_clock_class_get_name(stream_clock_class));
1244 ret = -1;
1245 goto end;
1246 }
1247
1248 if (stream_class->clock_class &&
1249 stream_class->clock_class !=
1250 stream_class->clock->clock_class) {
1251 /*
1252 * Stream class already has an expected clock
1253 * class, but it does not match its clock's
1254 * class.
1255 */
1256 BT_LOGW("Invalid parameter: stream class's clock's "
1257 "class does not match stream class's "
1258 "expected clock class: "
1259 "stream-class-addr=%p, "
1260 "stream-class-id=%" PRId64 ", "
1261 "stream-class-name=\"%s\", "
1262 "expected-clock-class-addr=%p, "
1263 "expected-clock-class-name=\"%s\"",
1264 stream_class,
1265 bt_stream_class_get_id(stream_class),
1266 bt_stream_class_get_name(stream_class),
1267 expected_clock_class,
1268 bt_clock_class_get_name(expected_clock_class));
1269 } else if (!stream_class->clock_class) {
1270 /*
1271 * Set expected clock class to stream class's
1272 * clock's class.
1273 */
1274 expected_clock_class =
1275 bt_get(stream_class->clock->clock_class);
1276 }
1277 }
1278
1279 if (!stream_class->frozen) {
1280 /*
1281 * Stream class is not frozen yet. Validate that the
1282 * stream class contains at most a single clock class
1283 * because the previous
1284 * bt_stream_class_add_event_class() calls did not make
1285 * this validation since the stream class's direct field
1286 * types (packet context, event header, event context)
1287 * could change afterwards. This stream class is about
1288 * to be frozen and those field types won't be changed
1289 * if this function succeeds.
1290 *
1291 * At this point we're also sure that the stream class's
1292 * clock, if any, has the same class as the stream
1293 * class's expected clock class, if any. This is why, if
1294 * bt_stream_class_validate_single_clock_class()
1295 * succeeds below, the call to
1296 * bt_stream_class_map_clock_class() at the end of this
1297 * function is safe because it maps to the same, single
1298 * clock class.
1299 */
1300 ret = bt_stream_class_validate_single_clock_class(stream_class,
1301 &expected_clock_class);
1302 if (ret) {
1303 BT_LOGW("Invalid parameter: stream class or one of its "
1304 "event classes contains a field type which is "
1305 "not recursively mapped to the expected "
1306 "clock class: "
1307 "stream-class-addr=%p, "
1308 "stream-class-id=%" PRId64 ", "
1309 "stream-class-name=\"%s\", "
1310 "expected-clock-class-addr=%p, "
1311 "expected-clock-class-name=\"%s\"",
1312 stream_class, bt_stream_class_get_id(stream_class),
1313 bt_stream_class_get_name(stream_class),
1314 expected_clock_class,
1315 expected_clock_class ?
1316 bt_clock_class_get_name(expected_clock_class) :
1317 NULL);
1318 goto end;
1319 }
1320 }
1321
1322 ret = check_packet_header_type_has_no_clock_class(trace);
1323 if (ret) {
1324 /* check_packet_header_type_has_no_clock_class() logs errors */
1325 goto end;
1326 }
1327
1328 /*
1329 * We're about to freeze both the trace and the stream class.
1330 * Also, each event class contained in this stream class are
1331 * already frozen.
1332 *
1333 * This trace, this stream class, and all its event classes
1334 * should be valid at this point.
1335 *
1336 * Validate trace and stream class first, then each event
1337 * class of this stream class can be validated individually.
1338 */
1339 packet_header_type =
1340 bt_trace_get_packet_header_type(trace);
1341 packet_context_type =
1342 bt_stream_class_get_packet_context_type(stream_class);
1343 event_header_type =
1344 bt_stream_class_get_event_header_type(stream_class);
1345 stream_event_ctx_type =
1346 bt_stream_class_get_event_context_type(stream_class);
1347
1348 BT_LOGD("Validating trace and stream class field types.");
1349 ret = bt_validate_class_types(trace->environment,
1350 packet_header_type, packet_context_type, event_header_type,
1351 stream_event_ctx_type, NULL, NULL, trace->valid,
1352 stream_class->valid, 1, &trace_sc_validation_output,
1353 trace_sc_validation_flags);
1354 BT_PUT(packet_header_type);
1355 BT_PUT(packet_context_type);
1356 BT_PUT(event_header_type);
1357 BT_PUT(stream_event_ctx_type);
1358
1359 if (ret) {
1360 /*
1361 * This means something went wrong during the validation
1362 * process, not that the objects are invalid.
1363 */
1364 BT_LOGE("Failed to validate trace and stream class field types: "
1365 "ret=%d", ret);
1366 goto end;
1367 }
1368
1369 if ((trace_sc_validation_output.valid_flags &
1370 trace_sc_validation_flags) !=
1371 trace_sc_validation_flags) {
1372 /* Invalid trace/stream class */
1373 BT_LOGW("Invalid trace or stream class field types: "
1374 "valid-flags=0x%x",
1375 trace_sc_validation_output.valid_flags);
1376 ret = -1;
1377 goto end;
1378 }
1379
1380 if (event_class_count > 0) {
1381 ec_validation_outputs = g_new0(struct bt_validation_output,
1382 event_class_count);
1383 if (!ec_validation_outputs) {
1384 BT_LOGE_STR("Failed to allocate one validation output structure.");
1385 ret = -1;
1386 goto end;
1387 }
1388 }
1389
1390 /* Validate each event class individually */
1391 for (i = 0; i < event_class_count; i++) {
1392 struct bt_event_class *event_class =
1393 bt_stream_class_get_event_class_by_index(
1394 stream_class, i);
1395 struct bt_field_type *event_context_type = NULL;
1396 struct bt_field_type *event_payload_type = NULL;
1397
1398 event_context_type =
1399 bt_event_class_get_context_type(event_class);
1400 event_payload_type =
1401 bt_event_class_get_payload_type(event_class);
1402
1403 /*
1404 * It is important to use the field types returned by
1405 * the previous trace and stream class validation here
1406 * because copies could have been made.
1407 */
1408 BT_LOGD("Validating event class's field types: "
1409 "addr=%p, name=\"%s\", id=%" PRId64,
1410 event_class, bt_event_class_get_name(event_class),
1411 bt_event_class_get_id(event_class));
1412 ret = bt_validate_class_types(trace->environment,
1413 trace_sc_validation_output.packet_header_type,
1414 trace_sc_validation_output.packet_context_type,
1415 trace_sc_validation_output.event_header_type,
1416 trace_sc_validation_output.stream_event_ctx_type,
1417 event_context_type, event_payload_type,
1418 1, 1, event_class->valid, &ec_validation_outputs[i],
1419 ec_validation_flags);
1420 BT_PUT(event_context_type);
1421 BT_PUT(event_payload_type);
1422 BT_PUT(event_class);
1423
1424 if (ret) {
1425 BT_LOGE("Failed to validate event class field types: "
1426 "ret=%d", ret);
1427 goto end;
1428 }
1429
1430 if ((ec_validation_outputs[i].valid_flags &
1431 ec_validation_flags) != ec_validation_flags) {
1432 /* Invalid event class */
1433 BT_LOGW("Invalid event class field types: "
1434 "valid-flags=0x%x",
1435 ec_validation_outputs[i].valid_flags);
1436 ret = -1;
1437 goto end;
1438 }
1439 }
1440
1441 stream_id = bt_stream_class_get_id(stream_class);
1442 if (stream_id < 0) {
1443 stream_id = trace->next_stream_id++;
1444 if (stream_id < 0) {
1445 BT_LOGE_STR("No more stream class IDs available.");
1446 ret = -1;
1447 goto end;
1448 }
1449
1450 /* Try to assign a new stream id */
1451 for (i = 0; i < trace->stream_classes->len; i++) {
1452 if (stream_id == bt_stream_class_get_id(
1453 trace->stream_classes->pdata[i])) {
1454 /* Duplicate stream id found */
1455 BT_LOGW("Duplicate stream class ID: "
1456 "id=%" PRId64, (int64_t) stream_id);
1457 ret = -1;
1458 goto end;
1459 }
1460 }
1461
1462 if (bt_stream_class_set_id_no_check(stream_class,
1463 stream_id)) {
1464 /* TODO Should retry with a different stream id */
1465 BT_LOGE("Cannot set stream class's ID: "
1466 "id=%" PRId64, (int64_t) stream_id);
1467 ret = -1;
1468 goto end;
1469 }
1470 }
1471
1472 /*
1473 * At this point all the field types in the validation output
1474 * are valid. Validate the semantics of some scopes according to
1475 * the CTF specification.
1476 */
1477 if (!packet_header_field_type_is_valid(trace,
1478 trace_sc_validation_output.packet_header_type)) {
1479 BT_LOGW_STR("Invalid trace's packet header field type.");
1480 ret = -1;
1481 goto end;
1482 }
1483
1484 if (!packet_context_field_type_is_valid(trace,
1485 stream_class,
1486 trace_sc_validation_output.packet_context_type)) {
1487 BT_LOGW_STR("Invalid stream class's packet context field type.");
1488 ret = -1;
1489 goto end;
1490 }
1491
1492 if (!event_header_field_type_is_valid(trace,
1493 stream_class,
1494 trace_sc_validation_output.event_header_type)) {
1495 BT_LOGW_STR("Invalid steam class's event header field type.");
1496 ret = -1;
1497 goto end;
1498 }
1499
1500 /*
1501 * Now is the time to automatically map specific field types of
1502 * the stream class's packet context and event header field
1503 * types to the stream class's clock's class if they are not
1504 * mapped to a clock class yet. We do it here because we know
1505 * that after this point, everything is frozen so it won't be
1506 * possible for the user to modify the stream class's clock, or
1507 * to map those field types to other clock classes.
1508 */
1509 if (trace->is_created_by_writer) {
1510 if (bt_stream_class_map_clock_class(stream_class,
1511 trace_sc_validation_output.packet_context_type,
1512 trace_sc_validation_output.event_header_type)) {
1513 BT_LOGW_STR("Cannot automatically map selected stream class's field types to stream class's clock's class.");
1514 ret = -1;
1515 goto end;
1516 }
1517 }
1518
1519
1520
1521 bt_object_set_parent(stream_class, trace);
1522 g_ptr_array_add(trace->stream_classes, stream_class);
1523
1524 /*
1525 * At this point we know that the function will be successful.
1526 * Therefore we can replace the trace and stream class field
1527 * types with what's in their validation output structure and
1528 * mark them as valid. We can also replace the field types of
1529 * all the event classes of the stream class and mark them as
1530 * valid.
1531 */
1532 bt_validation_replace_types(trace, stream_class, NULL,
1533 &trace_sc_validation_output, trace_sc_validation_flags);
1534 trace->valid = 1;
1535 stream_class->valid = 1;
1536
1537 /*
1538 * Put what was not moved in bt_validation_replace_types().
1539 */
1540 bt_validation_output_put_types(&trace_sc_validation_output);
1541
1542 for (i = 0; i < event_class_count; i++) {
1543 struct bt_event_class *event_class =
1544 bt_stream_class_get_event_class_by_index(
1545 stream_class, i);
1546
1547 bt_validation_replace_types(NULL, NULL, event_class,
1548 &ec_validation_outputs[i], ec_validation_flags);
1549 event_class->valid = 1;
1550 BT_PUT(event_class);
1551
1552 /*
1553 * Put what was not moved in
1554 * bt_validation_replace_types().
1555 */
1556 bt_validation_output_put_types(&ec_validation_outputs[i]);
1557 }
1558
1559 /*
1560 * Freeze the trace and the stream class.
1561 */
1562 bt_stream_class_freeze(stream_class);
1563 bt_trace_freeze(trace);
1564
1565 /*
1566 * It is safe to set the stream class's unique clock class
1567 * now because the stream class is frozen.
1568 */
1569 if (expected_clock_class) {
1570 BT_MOVE(stream_class->clock_class, expected_clock_class);
1571 }
1572
1573 /* Notifiy listeners of the trace's schema modification. */
1574 bt_stream_class_visit(stream_class,
1575 bt_trace_object_modification, trace);
1576 BT_LOGD("Added stream class to trace: "
1577 "trace-addr=%p, trace-name=\"%s\", "
1578 "stream-class-addr=%p, stream-class-name=\"%s\", "
1579 "stream-class-id=%" PRId64,
1580 trace, bt_trace_get_name(trace),
1581 stream_class, bt_stream_class_get_name(stream_class),
1582 bt_stream_class_get_id(stream_class));
1583
1584 end:
1585 if (ret) {
1586 bt_object_set_parent(stream_class, NULL);
1587
1588 if (ec_validation_outputs) {
1589 for (i = 0; i < event_class_count; i++) {
1590 bt_validation_output_put_types(
1591 &ec_validation_outputs[i]);
1592 }
1593 }
1594 }
1595
1596 g_free(ec_validation_outputs);
1597 bt_validation_output_put_types(&trace_sc_validation_output);
1598 bt_put(current_parent_trace);
1599 bt_put(expected_clock_class);
1600 assert(!packet_header_type);
1601 assert(!packet_context_type);
1602 assert(!event_header_type);
1603 assert(!stream_event_ctx_type);
1604 return ret;
1605 }
1606
1607 int64_t bt_trace_get_stream_count(struct bt_trace *trace)
1608 {
1609 int64_t ret;
1610
1611 if (!trace) {
1612 BT_LOGW_STR("Invalid parameter: trace is NULL.");
1613 ret = (int64_t) -1;
1614 goto end;
1615 }
1616
1617 ret = (int64_t) trace->streams->len;
1618
1619 end:
1620 return ret;
1621 }
1622
1623 struct bt_stream *bt_trace_get_stream_by_index(
1624 struct bt_trace *trace,
1625 uint64_t index)
1626 {
1627 struct bt_stream *stream = NULL;
1628
1629 if (!trace) {
1630 BT_LOGW_STR("Invalid parameter: trace is NULL.");
1631 goto end;
1632 }
1633
1634 if (index >= trace->streams->len) {
1635 BT_LOGW("Invalid parameter: index is out of bounds: "
1636 "addr=%p, name=\"%s\", "
1637 "index=%" PRIu64 ", count=%u",
1638 trace, bt_trace_get_name(trace),
1639 index, trace->streams->len);
1640 goto end;
1641 }
1642
1643 stream = bt_get(g_ptr_array_index(trace->streams, index));
1644
1645 end:
1646 return stream;
1647 }
1648
1649 int64_t bt_trace_get_stream_class_count(struct bt_trace *trace)
1650 {
1651 int64_t ret;
1652
1653 if (!trace) {
1654 BT_LOGW_STR("Invalid parameter: trace is NULL.");
1655 ret = (int64_t) -1;
1656 goto end;
1657 }
1658
1659 ret = (int64_t) trace->stream_classes->len;
1660 end:
1661 return ret;
1662 }
1663
1664 struct bt_stream_class *bt_trace_get_stream_class_by_index(
1665 struct bt_trace *trace, uint64_t index)
1666 {
1667 struct bt_stream_class *stream_class = NULL;
1668
1669 if (!trace) {
1670 BT_LOGW_STR("Invalid parameter: trace is NULL.");
1671 goto end;
1672 }
1673
1674 if (index >= trace->stream_classes->len) {
1675 BT_LOGW("Invalid parameter: index is out of bounds: "
1676 "addr=%p, name=\"%s\", "
1677 "index=%" PRIu64 ", count=%u",
1678 trace, bt_trace_get_name(trace),
1679 index, trace->stream_classes->len);
1680 goto end;
1681 }
1682
1683 stream_class = g_ptr_array_index(trace->stream_classes, index);
1684 bt_get(stream_class);
1685 end:
1686 return stream_class;
1687 }
1688
1689 struct bt_stream_class *bt_trace_get_stream_class_by_id(
1690 struct bt_trace *trace, uint64_t id_param)
1691 {
1692 int i;
1693 struct bt_stream_class *stream_class = NULL;
1694 int64_t id = (int64_t) id_param;
1695
1696 if (!trace) {
1697 BT_LOGW_STR("Invalid parameter: trace is NULL.");
1698 goto end;
1699 }
1700
1701 if (id < 0) {
1702 BT_LOGW("Invalid parameter: invalid stream class's ID: "
1703 "trace-addr=%p, trace-name=\"%s\", id=%" PRIu64,
1704 trace, bt_trace_get_name(trace), id_param);
1705 goto end;
1706 }
1707
1708 for (i = 0; i < trace->stream_classes->len; i++) {
1709 struct bt_stream_class *stream_class_candidate;
1710
1711 stream_class_candidate =
1712 g_ptr_array_index(trace->stream_classes, i);
1713
1714 if (bt_stream_class_get_id(stream_class_candidate) ==
1715 (int64_t) id) {
1716 stream_class = stream_class_candidate;
1717 bt_get(stream_class);
1718 goto end;
1719 }
1720 }
1721
1722 end:
1723 return stream_class;
1724 }
1725
1726 struct bt_clock_class *bt_trace_get_clock_class_by_name(
1727 struct bt_trace *trace, const char *name)
1728 {
1729 size_t i;
1730 struct bt_clock_class *clock_class = NULL;
1731
1732 if (!trace) {
1733 BT_LOGW_STR("Invalid parameter: trace is NULL.");
1734 goto end;
1735 }
1736
1737 if (!name) {
1738 BT_LOGW_STR("Invalid parameter: name is NULL.");
1739 goto end;
1740 }
1741
1742 for (i = 0; i < trace->clocks->len; i++) {
1743 struct bt_clock_class *cur_clk =
1744 g_ptr_array_index(trace->clocks, i);
1745 const char *cur_clk_name = bt_clock_class_get_name(cur_clk);
1746
1747 if (!cur_clk_name) {
1748 goto end;
1749 }
1750
1751 if (!strcmp(cur_clk_name, name)) {
1752 clock_class = cur_clk;
1753 bt_get(clock_class);
1754 goto end;
1755 }
1756 }
1757
1758 end:
1759 return clock_class;
1760 }
1761
1762 BT_HIDDEN
1763 bt_bool bt_trace_has_clock_class(struct bt_trace *trace,
1764 struct bt_clock_class *clock_class)
1765 {
1766 struct search_query query = { .value = clock_class, .found = 0 };
1767
1768 assert(trace);
1769 assert(clock_class);
1770
1771 g_ptr_array_foreach(trace->clocks, value_exists, &query);
1772 return query.found;
1773 }
1774
1775 BT_HIDDEN
1776 const char *get_byte_order_string(enum bt_byte_order byte_order)
1777 {
1778 const char *string;
1779
1780 switch (byte_order) {
1781 case BT_BYTE_ORDER_LITTLE_ENDIAN:
1782 string = "le";
1783 break;
1784 case BT_BYTE_ORDER_BIG_ENDIAN:
1785 string = "be";
1786 break;
1787 case BT_BYTE_ORDER_NATIVE:
1788 string = "native";
1789 break;
1790 default:
1791 abort();
1792 }
1793
1794 return string;
1795 }
1796
1797 static
1798 int append_trace_metadata(struct bt_trace *trace,
1799 struct metadata_context *context)
1800 {
1801 unsigned char *uuid = trace->uuid;
1802 int ret = 0;
1803
1804 if (trace->native_byte_order == BT_BYTE_ORDER_NATIVE ||
1805 trace->native_byte_order == BT_BYTE_ORDER_UNSPECIFIED) {
1806 BT_LOGW("Invalid parameter: trace's byte order cannot be BT_BYTE_ORDER_NATIVE or BT_BYTE_ORDER_UNSPECIFIED at this point; "
1807 "set it with bt_trace_set_native_byte_order(): "
1808 "addr=%p, name=\"%s\"",
1809 trace, bt_trace_get_name(trace));
1810 ret = -1;
1811 goto end;
1812 }
1813
1814 g_string_append(context->string, "trace {\n");
1815 g_string_append(context->string, "\tmajor = 1;\n");
1816 g_string_append(context->string, "\tminor = 8;\n");
1817 assert(trace->native_byte_order == BT_BYTE_ORDER_LITTLE_ENDIAN ||
1818 trace->native_byte_order == BT_BYTE_ORDER_BIG_ENDIAN ||
1819 trace->native_byte_order == BT_BYTE_ORDER_NETWORK);
1820
1821 if (trace->uuid_set) {
1822 g_string_append_printf(context->string,
1823 "\tuuid = \"%02x%02x%02x%02x-%02x%02x-%02x%02x-%02x%02x-%02x%02x%02x%02x%02x%02x\";\n",
1824 uuid[0], uuid[1], uuid[2], uuid[3],
1825 uuid[4], uuid[5], uuid[6], uuid[7],
1826 uuid[8], uuid[9], uuid[10], uuid[11],
1827 uuid[12], uuid[13], uuid[14], uuid[15]);
1828 }
1829
1830 g_string_append_printf(context->string, "\tbyte_order = %s;\n",
1831 get_byte_order_string(trace->native_byte_order));
1832
1833 if (trace->packet_header_type) {
1834 g_string_append(context->string, "\tpacket.header := ");
1835 context->current_indentation_level++;
1836 g_string_assign(context->field_name, "");
1837 BT_LOGD_STR("Serializing trace's packet header field type's metadata.");
1838 ret = bt_field_type_serialize(trace->packet_header_type,
1839 context);
1840 if (ret) {
1841 goto end;
1842 }
1843 context->current_indentation_level--;
1844 }
1845
1846 g_string_append(context->string, ";\n};\n\n");
1847 end:
1848 return ret;
1849 }
1850
1851 static
1852 void append_env_metadata(struct bt_trace *trace,
1853 struct metadata_context *context)
1854 {
1855 int64_t i;
1856 int64_t env_size;
1857
1858 env_size = bt_attributes_get_count(trace->environment);
1859 if (env_size <= 0) {
1860 return;
1861 }
1862
1863 g_string_append(context->string, "env {\n");
1864
1865 for (i = 0; i < env_size; i++) {
1866 struct bt_value *env_field_value_obj = NULL;
1867 const char *entry_name;
1868
1869 entry_name = bt_attributes_get_field_name(
1870 trace->environment, i);
1871 env_field_value_obj = bt_attributes_get_field_value(
1872 trace->environment, i);
1873
1874 assert(entry_name);
1875 assert(env_field_value_obj);
1876
1877 switch (bt_value_get_type(env_field_value_obj)) {
1878 case BT_VALUE_TYPE_INTEGER:
1879 {
1880 int ret;
1881 int64_t int_value;
1882
1883 ret = bt_value_integer_get(env_field_value_obj,
1884 &int_value);
1885 assert(ret == 0);
1886 g_string_append_printf(context->string,
1887 "\t%s = %" PRId64 ";\n", entry_name,
1888 int_value);
1889 break;
1890 }
1891 case BT_VALUE_TYPE_STRING:
1892 {
1893 int ret;
1894 const char *str_value;
1895 char *escaped_str = NULL;
1896
1897 ret = bt_value_string_get(env_field_value_obj,
1898 &str_value);
1899 assert(ret == 0);
1900 escaped_str = g_strescape(str_value, NULL);
1901 if (!escaped_str) {
1902 BT_LOGE("Cannot escape string: string=\"%s\"",
1903 str_value);
1904 goto loop_next;
1905 }
1906
1907 g_string_append_printf(context->string,
1908 "\t%s = \"%s\";\n", entry_name, escaped_str);
1909 free(escaped_str);
1910 break;
1911 }
1912 default:
1913 goto loop_next;
1914 }
1915
1916 loop_next:
1917 BT_PUT(env_field_value_obj);
1918 }
1919
1920 g_string_append(context->string, "};\n\n");
1921 }
1922
1923 char *bt_trace_get_metadata_string(struct bt_trace *trace)
1924 {
1925 char *metadata = NULL;
1926 struct metadata_context *context = NULL;
1927 int err = 0;
1928 size_t i;
1929
1930 if (!trace) {
1931 BT_LOGW_STR("Invalid parameter: trace is NULL.");
1932 goto end;
1933 }
1934
1935 context = g_new0(struct metadata_context, 1);
1936 if (!context) {
1937 BT_LOGE_STR("Failed to allocate one metadata context.");
1938 goto end;
1939 }
1940
1941 context->field_name = g_string_sized_new(DEFAULT_IDENTIFIER_SIZE);
1942 context->string = g_string_sized_new(DEFAULT_METADATA_STRING_SIZE);
1943 g_string_append(context->string, "/* CTF 1.8 */\n\n");
1944 if (append_trace_metadata(trace, context)) {
1945 /* append_trace_metadata() logs errors */
1946 goto error;
1947 }
1948 append_env_metadata(trace, context);
1949 g_ptr_array_foreach(trace->clocks,
1950 (GFunc)bt_clock_class_serialize, context);
1951
1952 for (i = 0; i < trace->stream_classes->len; i++) {
1953 /* bt_stream_class_serialize() logs details */
1954 err = bt_stream_class_serialize(
1955 trace->stream_classes->pdata[i], context);
1956 if (err) {
1957 /* bt_stream_class_serialize() logs errors */
1958 goto error;
1959 }
1960 }
1961
1962 metadata = context->string->str;
1963
1964 error:
1965 g_string_free(context->string, err ? TRUE : FALSE);
1966 g_string_free(context->field_name, TRUE);
1967 g_free(context);
1968
1969 end:
1970 return metadata;
1971 }
1972
1973 enum bt_byte_order bt_trace_get_native_byte_order(
1974 struct bt_trace *trace)
1975 {
1976 enum bt_byte_order ret = BT_BYTE_ORDER_UNKNOWN;
1977
1978 if (!trace) {
1979 BT_LOGW_STR("Invalid parameter: trace is NULL.");
1980 goto end;
1981 }
1982
1983 ret = trace->native_byte_order;
1984
1985 end:
1986 return ret;
1987 }
1988
1989 int bt_trace_set_native_byte_order(struct bt_trace *trace,
1990 enum bt_byte_order byte_order)
1991 {
1992 int ret = 0;
1993
1994 if (!trace) {
1995 BT_LOGW_STR("Invalid parameter: trace is NULL.");
1996 ret = -1;
1997 goto end;
1998 }
1999
2000 if (trace->frozen) {
2001 BT_LOGW("Invalid parameter: trace is frozen: "
2002 "addr=%p, name=\"%s\"",
2003 trace, bt_trace_get_name(trace));
2004 ret = -1;
2005 goto end;
2006 }
2007
2008 if (trace->is_created_by_writer &&
2009 byte_order == BT_BYTE_ORDER_UNSPECIFIED) {
2010 BT_LOGW("Invalid parameter: BT_BYTE_ORDER_UNSPECIFIED byte order is not allowed for a CTF writer trace: "
2011 "addr=%p, name=\"%s\"",
2012 trace, bt_trace_get_name(trace));
2013 ret = -1;
2014 goto end;
2015 }
2016
2017 if (byte_order != BT_BYTE_ORDER_LITTLE_ENDIAN &&
2018 byte_order != BT_BYTE_ORDER_BIG_ENDIAN &&
2019 byte_order != BT_BYTE_ORDER_NETWORK) {
2020 BT_LOGW("Invalid parameter: invalid byte order: "
2021 "addr=%p, name=\"%s\", bo=%s",
2022 trace, bt_trace_get_name(trace),
2023 bt_byte_order_string(byte_order));
2024 ret = -1;
2025 goto end;
2026 }
2027
2028 trace->native_byte_order = byte_order;
2029 BT_LOGV("Set trace's native byte order: "
2030 "addr=%p, name=\"%s\", bo=%s",
2031 trace, bt_trace_get_name(trace),
2032 bt_byte_order_string(byte_order));
2033
2034 end:
2035 return ret;
2036 }
2037
2038 struct bt_field_type *bt_trace_get_packet_header_type(
2039 struct bt_trace *trace)
2040 {
2041 struct bt_field_type *field_type = NULL;
2042
2043 if (!trace) {
2044 BT_LOGW_STR("Invalid parameter: trace is NULL.");
2045 goto end;
2046 }
2047
2048 bt_get(trace->packet_header_type);
2049 field_type = trace->packet_header_type;
2050 end:
2051 return field_type;
2052 }
2053
2054 int bt_trace_set_packet_header_type(struct bt_trace *trace,
2055 struct bt_field_type *packet_header_type)
2056 {
2057 int ret = 0;
2058
2059 if (!trace) {
2060 BT_LOGW_STR("Invalid parameter: trace is NULL.");
2061 ret = -1;
2062 goto end;
2063 }
2064
2065 if (trace->frozen) {
2066 BT_LOGW("Invalid parameter: trace is frozen: "
2067 "addr=%p, name=\"%s\"",
2068 trace, bt_trace_get_name(trace));
2069 ret = -1;
2070 goto end;
2071 }
2072
2073 /* packet_header_type must be a structure. */
2074 if (packet_header_type &&
2075 !bt_field_type_is_structure(packet_header_type)) {
2076 BT_LOGW("Invalid parameter: packet header field type must be a structure field type if it exists: "
2077 "addr=%p, name=\"%s\", ft-addr=%p, ft-id=%s",
2078 trace, bt_trace_get_name(trace),
2079 packet_header_type,
2080 bt_field_type_id_string(packet_header_type->id));
2081 ret = -1;
2082 goto end;
2083 }
2084
2085 bt_put(trace->packet_header_type);
2086 trace->packet_header_type = bt_get(packet_header_type);
2087 BT_LOGV("Set trace's packet header field type: "
2088 "addr=%p, name=\"%s\", packet-context-ft-addr=%p",
2089 trace, bt_trace_get_name(trace), packet_header_type);
2090 end:
2091 return ret;
2092 }
2093
2094 static
2095 int64_t get_stream_class_count(void *element)
2096 {
2097 return bt_trace_get_stream_class_count(
2098 (struct bt_trace *) element);
2099 }
2100
2101 static
2102 void *get_stream_class(void *element, int i)
2103 {
2104 return bt_trace_get_stream_class_by_index(
2105 (struct bt_trace *) element, i);
2106 }
2107
2108 static
2109 int visit_stream_class(void *object, bt_visitor visitor,void *data)
2110 {
2111 return bt_stream_class_visit(object, visitor, data);
2112 }
2113
2114 int bt_trace_visit(struct bt_trace *trace,
2115 bt_visitor visitor, void *data)
2116 {
2117 int ret;
2118 struct bt_visitor_object obj = {
2119 .object = trace,
2120 .type = BT_VISITOR_OBJECT_TYPE_TRACE
2121 };
2122
2123 if (!trace) {
2124 BT_LOGW_STR("Invalid parameter: trace is NULL.");
2125 ret = -1;
2126 goto end;
2127 }
2128
2129 if (!visitor) {
2130 BT_LOGW_STR("Invalid parameter: visitor is NULL.");
2131 ret = -1;
2132 goto end;
2133 }
2134
2135 BT_LOGV("Visiting trace: addr=%p, name=\"%s\"",
2136 trace, bt_trace_get_name(trace));
2137 ret = visitor_helper(&obj, get_stream_class_count,
2138 get_stream_class, visit_stream_class, visitor, data);
2139 end:
2140 return ret;
2141 }
2142
2143 static
2144 int invoke_listener(struct bt_visitor_object *object, void *data)
2145 {
2146 struct listener_wrapper *listener_wrapper = data;
2147
2148 listener_wrapper->listener(object, listener_wrapper->data);
2149 return 0;
2150 }
2151
2152 // TODO: add logging to this function once we use it internally.
2153 int bt_trace_add_listener(struct bt_trace *trace,
2154 bt_listener_cb listener, void *listener_data)
2155 {
2156 int ret = 0;
2157 struct listener_wrapper *listener_wrapper =
2158 g_new0(struct listener_wrapper, 1);
2159
2160 if (!trace || !listener || !listener_wrapper) {
2161 ret = -1;
2162 goto error;
2163 }
2164
2165 listener_wrapper->listener = listener;
2166 listener_wrapper->data = listener_data;
2167
2168 /* Visit the current schema. */
2169 ret = bt_trace_visit(trace, invoke_listener, listener_wrapper);
2170 if (ret) {
2171 goto error;
2172 }
2173
2174 /*
2175 * Add listener to the array of callbacks which will be invoked on
2176 * schema changes.
2177 */
2178 g_ptr_array_add(trace->listeners, listener_wrapper);
2179 return ret;
2180 error:
2181 g_free(listener_wrapper);
2182 return ret;
2183 }
2184
2185 BT_HIDDEN
2186 int bt_trace_object_modification(struct bt_visitor_object *object,
2187 void *trace_ptr)
2188 {
2189 size_t i;
2190 struct bt_trace *trace = trace_ptr;
2191
2192 assert(trace);
2193 assert(object);
2194
2195 if (trace->listeners->len == 0) {
2196 goto end;
2197 }
2198
2199 for (i = 0; i < trace->listeners->len; i++) {
2200 struct listener_wrapper *listener =
2201 g_ptr_array_index(trace->listeners, i);
2202
2203 listener->listener(object, listener->data);
2204 }
2205 end:
2206 return 0;
2207 }
2208
2209 BT_HIDDEN
2210 struct bt_field_type *get_field_type(enum field_type_alias alias)
2211 {
2212 int ret;
2213 unsigned int alignment, size;
2214 struct bt_field_type *field_type = NULL;
2215
2216 if (alias >= NR_FIELD_TYPE_ALIAS) {
2217 goto end;
2218 }
2219
2220 alignment = field_type_aliases_alignments[alias];
2221 size = field_type_aliases_sizes[alias];
2222 field_type = bt_field_type_integer_create(size);
2223 ret = bt_field_type_set_alignment(field_type, alignment);
2224 if (ret) {
2225 BT_PUT(field_type);
2226 }
2227 end:
2228 return field_type;
2229 }
2230
2231 static
2232 void bt_trace_freeze(struct bt_trace *trace)
2233 {
2234 int i;
2235
2236 if (trace->frozen) {
2237 return;
2238 }
2239
2240 BT_LOGD("Freezing trace: addr=%p, name=\"%s\"",
2241 trace, bt_trace_get_name(trace));
2242 BT_LOGD_STR("Freezing packet header field type.");
2243 bt_field_type_freeze(trace->packet_header_type);
2244 BT_LOGD_STR("Freezing environment attributes.");
2245 bt_attributes_freeze(trace->environment);
2246
2247 if (trace->clocks->len > 0) {
2248 BT_LOGD_STR("Freezing clock classes.");
2249 }
2250
2251 for (i = 0; i < trace->clocks->len; i++) {
2252 struct bt_clock_class *clock_class =
2253 g_ptr_array_index(trace->clocks, i);
2254
2255 bt_clock_class_freeze(clock_class);
2256 }
2257
2258 trace->frozen = 1;
2259 }
2260
2261 bt_bool bt_trace_is_static(struct bt_trace *trace)
2262 {
2263 bt_bool is_static = BT_FALSE;
2264
2265 if (!trace) {
2266 BT_LOGW_STR("Invalid parameter: trace is NULL.");
2267 goto end;
2268 }
2269
2270 is_static = trace->is_static;
2271
2272 end:
2273 return is_static;
2274 }
2275
2276 int bt_trace_set_is_static(struct bt_trace *trace)
2277 {
2278 int ret = 0;
2279 size_t i;
2280
2281 if (!trace) {
2282 BT_LOGW_STR("Invalid parameter: trace is NULL.");
2283 ret = -1;
2284 goto end;
2285 }
2286
2287 ret = check_packet_header_type_has_no_clock_class(trace);
2288 if (ret) {
2289 /* check_packet_header_type_has_no_clock_class() logs errors */
2290 goto end;
2291 }
2292
2293 trace->is_static = BT_TRUE;
2294 bt_trace_freeze(trace);
2295 BT_LOGV("Set trace static: addr=%p, name=\"%s\"",
2296 trace, bt_trace_get_name(trace));
2297
2298 /* Call all the "trace is static" listeners */
2299 for (i = 0; i < trace->is_static_listeners->len; i++) {
2300 struct bt_trace_is_static_listener_elem elem =
2301 g_array_index(trace->is_static_listeners,
2302 struct bt_trace_is_static_listener_elem, i);
2303
2304 if (elem.func) {
2305 elem.func(trace, elem.data);
2306 }
2307 }
2308
2309 end:
2310 return ret;
2311 }
2312
2313 int bt_trace_add_is_static_listener(struct bt_trace *trace,
2314 bt_trace_is_static_listener listener,
2315 bt_trace_listener_removed listener_removed, void *data)
2316 {
2317 int i;
2318 struct bt_trace_is_static_listener_elem new_elem = {
2319 .func = listener,
2320 .removed = listener_removed,
2321 .data = data,
2322 };
2323
2324 if (!trace) {
2325 BT_LOGW_STR("Invalid parameter: trace is NULL.");
2326 i = -1;
2327 goto end;
2328 }
2329
2330 if (!listener) {
2331 BT_LOGW_STR("Invalid parameter: listener is NULL.");
2332 i = -1;
2333 goto end;
2334 }
2335
2336 if (trace->is_static) {
2337 BT_LOGW("Invalid parameter: trace is already static: "
2338 "addr=%p, name=\"%s\"",
2339 trace, bt_trace_get_name(trace));
2340 i = -1;
2341 goto end;
2342 }
2343
2344 if (trace->in_remove_listener) {
2345 BT_LOGW("Cannot call this function during the execution of a remove listener: "
2346 "addr=%p, name=\"%s\"",
2347 trace, bt_trace_get_name(trace));
2348 i = -1;
2349 goto end;
2350 }
2351
2352 /* Find the next available spot */
2353 for (i = 0; i < trace->is_static_listeners->len; i++) {
2354 struct bt_trace_is_static_listener_elem elem =
2355 g_array_index(trace->is_static_listeners,
2356 struct bt_trace_is_static_listener_elem, i);
2357
2358 if (!elem.func) {
2359 break;
2360 }
2361 }
2362
2363 if (i == trace->is_static_listeners->len) {
2364 g_array_append_val(trace->is_static_listeners, new_elem);
2365 } else {
2366 g_array_insert_val(trace->is_static_listeners, i, new_elem);
2367 }
2368
2369 BT_LOGV("Added \"trace is static\" listener: "
2370 "trace-addr=%p, trace-name=\"%s\", func-addr=%p, "
2371 "data-addr=%p, listener-id=%d",
2372 trace, bt_trace_get_name(trace), listener, data, i);
2373
2374 end:
2375 return i;
2376 }
2377
2378 int bt_trace_remove_is_static_listener(
2379 struct bt_trace *trace, int listener_id)
2380 {
2381 int ret = 0;
2382 struct bt_trace_is_static_listener_elem *elem;
2383
2384 if (!trace) {
2385 BT_LOGW_STR("Invalid parameter: trace is NULL.");
2386 ret = -1;
2387 goto end;
2388 }
2389
2390 if (trace->in_remove_listener) {
2391 BT_LOGW("Cannot call this function during the execution of a remove listener: "
2392 "addr=%p, name=\"%s\", listener-id=%d",
2393 trace, bt_trace_get_name(trace),
2394 listener_id);
2395 ret = -1;
2396 goto end;
2397 }
2398
2399 if (listener_id < 0) {
2400 BT_LOGW("Invalid listener ID: must be zero or positive: "
2401 "listener-id=%d", listener_id);
2402 ret = -1;
2403 goto end;
2404 }
2405
2406 if (listener_id >= trace->is_static_listeners->len) {
2407 BT_LOGW("Invalid parameter: no listener with this listener ID: "
2408 "addr=%p, name=\"%s\", listener-id=%d",
2409 trace, bt_trace_get_name(trace),
2410 listener_id);
2411 ret = -1;
2412 goto end;
2413 }
2414
2415 elem = &g_array_index(trace->is_static_listeners,
2416 struct bt_trace_is_static_listener_elem,
2417 listener_id);
2418 if (!elem->func) {
2419 BT_LOGW("Invalid parameter: no listener with this listener ID: "
2420 "addr=%p, name=\"%s\", listener-id=%d",
2421 trace, bt_trace_get_name(trace),
2422 listener_id);
2423 ret = -1;
2424 goto end;
2425 }
2426
2427 if (elem->removed) {
2428 /* Call remove listener */
2429 BT_LOGV("Calling remove listener: "
2430 "trace-addr=%p, trace-name=\"%s\", "
2431 "listener-id=%d", trace, bt_trace_get_name(trace),
2432 listener_id);
2433 trace->in_remove_listener = BT_TRUE;
2434 elem->removed(trace, elem->data);
2435 trace->in_remove_listener = BT_FALSE;
2436 }
2437
2438 elem->func = NULL;
2439 elem->removed = NULL;
2440 elem->data = NULL;
2441 BT_LOGV("Removed \"trace is static\" listener: "
2442 "trace-addr=%p, trace-name=\"%s\", "
2443 "listener-id=%d", trace, bt_trace_get_name(trace),
2444 listener_id);
2445
2446 end:
2447 return ret;
2448 }
This page took 0.116702 seconds and 5 git commands to generate.